505
Views
9
CrossRef citations to date
0
Altmetric
Original Article

Safety of peripherally inserted central catheters during pregnancy: a retrospective study

, , , , , & show all
Pages 1166-1170 | Received 06 Jan 2017, Accepted 22 Mar 2017, Published online: 16 Apr 2017
 

Abstract

Purpose: We investigated the incidence of complications associated with peripherally inserted central line catheters, inserted using a standardized technique, during pregnancy and the postpartum period.

Materials and methods: A retrospective case series was performed that included all pregnant and postpartum women who received peripherally inserted central catheters (PICCs) at a single institution between 2006 and 2014. Patient demographics and data on infectious, mechanical and thrombotic complications were collected. Some patients required more than one line insertion during the same pregnancy. In these instances, only the first line placement for each subject was included in the analysis of complications.

Results: One hundred and forty-six catheters were inserted in 112 pregnant and postpartum patients. The total incidence of complications was 17% (19/112). Specific complications included infection (n = 4, 3.6%), mechanical (n = 5, 4.4%), deep venous thrombosis (n = 2, 1.8%) and other (n = 8, 7.1%). Demographics of the complication and no complication groups were similar.

Conclusions: In contrast with previous studies, we report a complication rate associated with peripheral line use in pregnant and postpartum women that appears similar to that in non-pregnant populations.

Ethical approval

This study was approved by the Medical College of Wisconsin IRB committee.

Date of approval: 9/30/14.

Reference ID: PRO00023396.

There was no funding for this project.

Acknowledgments

Brenda Jones, N P, at Froedtert Hospital and the Medical College of Wisconsin, assisted in data collection. No funding source. No compensation.

Tucker Keuter PhD and Anika Szabo PhD, from the Medical College of Wisconsin, assisted with statistical analysis. No funding source. No compensation.

Disclosure statement

The authors report no conflicts of interests or disclosures.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.