What Is an Effective Portable Air Cleaning Device? A Review

&
Pages 169-181 | Published online: 24 Oct 2007
 

The use of portable air cleaning devices in residential settings has been steadily growing over the last 10 years. Three out of every 10 households now contain a portable air cleaning device. This increased use of air cleaners is accompanied by, if not influenced by, a fundamental belief by consumers that the air cleaners are providing an improved indoor air environment. However, there is a wide variation in the performance of air cleaners that is dependent on the specific air cleaner design and various indoor factors. The most widely used method in the United States to assess the performance of new air cleaners is the procedure described in the American National Standards Institute (ANSI)/Association of Home Appliance Manufacturers (AHAM) AC-1-2002. This method describes both the test conditions and the testing protocol. The protocol yields a performance metric that is based on the measured decay rate of contaminant concentrations with the air cleaner operating compared with the measured decay rate with the air cleaner turned off. The resulting metric, the clean air delivery rate (CADR), permits both an intercomparison of performance among various air cleaners and a comparison of air cleaner operation to other contaminant removal processes. In this article, we comment on the testing process, discuss its applicability to various contaminants, and evaluate the resulting performance metrics for effective air cleaning.

Notes

A Reported CADR values are averages based on a 12-hour test.

B The highest CADR values listed here are for the UV-PCO device that incorporated a ∼ 9 cm thick carbon adsorber. When operated without the carbon bed, the UV-PCO device produced no significant removal.

C VOC listed in order of decreasing vapor pressure (vp); the first three have vp > 100 mm Hg (at 23°C); compounds 4 through 8 have vp between 10 and 100 mmHg; the last two have vp of 10 mmHg or less.

A Classification of particles based on approximate size = small: 0.1–0.8 micron; medium: 1–4 microns; large: 6–20 microns (see ).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 148.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.