Preparation and Certification of Two New Bulk Welding Fume Reference Materials for Use in Laboratories Undertaking Analysis of Occupational Hygiene Samples

, &

Figures & data

TABLE I. Participants and the Methodologies They Employed in the Certification Exercise

FIGURE 1. Zinc homogeneity results for HSL MSWF-1 together with resultant certified value and expanded uncertainty. The error bars indicate the standard deviation of the mean of triplicate measurements undertaken per bottle unit. The error bar associated with the resultant Zn certified value represents the corresponding expanded uncertainty arising from the certification exercise.
FIGURE 1. Zinc homogeneity results for HSL MSWF-1 together with resultant certified value and expanded uncertainty. The error bars indicate the standard deviation of the mean of triplicate measurements undertaken per bottle unit. The error bar associated with the resultant Zn certified value represents the corresponding expanded uncertainty arising from the certification exercise.

TABLE II. Results of the Zinc Homogeneity Study Conducted on HSL MSWF-1

FIGURE 2. Zinc stability results (to date) for HSL MSWF-1 together with resultant certified value and expanded uncertainty. The error bars indicate the standard deviation of the mean of triplicate measurements, over time, from a selected bottle unit. The error bar associated with the resultant Zn certified value represents the corresponding expanded uncertainty arising from the certification exercise.
FIGURE 2. Zinc stability results (to date) for HSL MSWF-1 together with resultant certified value and expanded uncertainty. The error bars indicate the standard deviation of the mean of triplicate measurements, over time, from a selected bottle unit. The error bar associated with the resultant Zn certified value represents the corresponding expanded uncertainty arising from the certification exercise.

TABLE III. Statistical Tests Carried Out on Participants’ Data

TABLE IV. Results of Statistical Tests Carried Out on Accepted Participants’ Data

FIGURE 3. Certification data for Zinc in HSL MSWF-1 from certification laboratories together with resultant certified value and expanded uncertainty. The error bars indicate the standard deviations of the mean of means from each of the individual laboratories (five Zn replicate aliquots tested from each of two bottles). The error bar associated with the plotted Zn certified value represents the corresponding expanded uncertainty arising from the certification exercise.
FIGURE 3. Certification data for Zinc in HSL MSWF-1 from certification laboratories together with resultant certified value and expanded uncertainty. The error bars indicate the standard deviations of the mean of means from each of the individual laboratories (five Zn replicate aliquots tested from each of two bottles). The error bar associated with the plotted Zn certified value represents the corresponding expanded uncertainty arising from the certification exercise.

TABLE V. Mass Fractions and Uncertainty Components for Zinc in HSL MSWF-1

TABLE VI. Certified Mass Fractions and Expanded Uncertainties of Elements in HSL MSWF-1

TABLE VII. Certified Mass Fractions and Expanded Uncertainties of Elements in HSL SSWF-1