410
Views
1
CrossRef citations to date
0
Altmetric
Articles

Double gloving of disposable nitrile gloves exposed to diethylene glycol mono-n-butyl ether

& ORCID Icon
Pages 334-342 | Published online: 29 May 2020
 

Abstract

Double gloving of disposable gloves is now commonplace in healthcare settings when extra protection is needed against aqueous solutions and especially for antineoplastic drugs in isotonic aqueous media. In the present study, an ASTM F739 2.54 cm cell with closed-loop water collection without recirculation at 35 °C in a moving tray water bath was used to test the permeation of diethylene glycol mono-n-butyl ether (DGBE) through four types of disposable nitrile gloves that were singly and doubly layered in the permeation cell. Samples were taken over 8 hr for capillary gas chromatograph-mass spectrometer quantitation. The breakthrough time (tn) at a permeation of 250 ng/cm2 increased as thickness increased for single layers, but the steady-state permeation rates Ps in µg/cm2/min did not always decrease with increasing thickness. The double-layer tn, Ps and thickness were also more variable relative to a single layer. The thinnest glove with 80 μm thickness showed a tn = 0–5 min whereas its double layer was 15–20 min. The thickest glove of 132 µm exhibited a tn = 10–15 min but its double layer was tn = 45–55 min. The adjusted double-layer average tn divided by the adjusted single-layer average tn was 4.0 ± 0.8. The adjusted average single-layer Ps divided by the adjusted average double-layer Ps was 3.5 ± 0.8. Other results showed that the average glove swelling was <10%; microscopic and leak testing indicated no penetration and reflectance infrared analysis also showed no chemical changes on the inside glove surfaces. Thus, the permeations were adjudged to obey Fick’s First Law of Diffusion to allow calculation of diffusion coefficients D in cm2/min. The average single-layer D divided by the average double-layer D was 1.3 ± 0.2. Double gloving in the field is therefore also probably more protective than single gloving against DGBE for the four types of disposable nitrile gloves tested.

Acknowledgments

The content is solely the responsibility of the authors and does not represent the official view of CDCP/NIOSH.

Disclosure statement

The authors deny conflict of interest in the present study.

Additional information

Funding

Funding was from NIOSH/CDC RO1 OH009250 and the UCLA Center for Occupational and Environmental Health, University of California, Los Angeles. Sayaka Takaku-Pugh was also supported by CDC/NIOSH T42 OH009412.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 148.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.