318
Views
14
CrossRef citations to date
0
Altmetric
Original Articles

Method validation for the determination of total mercury in fish muscle by cold vapour atomic absorption spectrometry

, , , , &
Pages 617-624 | Received 25 Nov 2010, Accepted 08 Nov 2011, Published online: 18 Jan 2012
 

Abstract

A method was validated for the determination of total Hg in fish muscle using continuous flow cold vapour atomic absorption (CVAAS) after microwave digestion in closed vessels. The method was validated according to European Union Regulations 333/2007 and 657/2002, considering the maximum level for the metal in fish, established by European Union regulation 1881/2006. The procedure for determining linear range, selectivity, recovery, precision, trueness, decision limit (CCα), detection capability (CCβ), measurement uncertainty and robustness of the method is reported. The results of the validation process demonstrate the method fulfils the provisions of the Commission Regulation. The selectivity study indicated that there was no matrix effect on the calibration curve between the concentration range of 1.0 and 30.0 µg Hg l−1. The mean recovery calculated at six levels of fortification was in the range of 94–104%. The limit of detection (LOD) and limit of quantification (LOQ) values were 4.90 and 15.7 µg kg−1, while the CCα and CCβ values were 0.517 and 0.533 mg kg−1, respectively, for the maximum contaminant level of 0.500 mg kg−1. The relative expanded measurement uncertainty of the method was 0.055 mg kg−1. The method was not affected by slight variations of some critical factors (ruggedness minor changes) as sample mass and volume of the HNO3 and H2O2 used in the digestion step. The method allowed accurate confirmation analyses of the CRM DORM 3®. In fact, the Z-scores attained in a proficiency test round were well below the reference value of 2.0, proving the excellent performance of the laboratory.

Acknowledgements

The authors thank CNPQ for a scholarship support programme; and the National Agriculture Laboratory at Pará State/MAPA for funds and facilities.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 799.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.