199
Views
31
CrossRef citations to date
0
Altmetric
Articles

Treatment of raw tannery wastewater by electrocoagulation technique: optimization of effective parameters using Taguchi method

&
Pages 14798-14809 | Received 19 Apr 2015, Accepted 19 Jun 2015, Published online: 25 Aug 2015
 

Abstract

In this study, the electrocoagulation (EC) technique for tannery wastewater treatment was examined using iron and aluminum electrodes. The effects of operating parameters that include current density, initial pH, and electrolysis time on EC performance were accomplished. In addition, Taguchi method was carried out in order to design the experiments and to optimize the experimental results. L25 orthogonal array (OA, three factors in five levels), signal-to-noise (S/N) ratio (the larger-the-better), and analysis of variance were applied to find the optimum levels and relative magnitude of the effects of parameters. The removal efficiency of chemical oxygen demand (COD), total chrome, and color are considered as the response parameters. In the case of iron electrodes, the optimum conditions of COD were found to be at the fifth level of current density (50 mA/cm2), the fourth level of initial pH (7), and fifth level of electrolysis time (25 min). According to total chrome, they were found at the third level of current density (30 mA/cm2), the fifth level of initial pH (8), and the fifth level of electrolysis time (25 min). In addition, with regard to color removal efficiency, they were determined to be at the fifth level of current density (50 mA/cm2), the fourth level of initial pH (7), and the fifth level of electrolysis time (25 min). At the optimum conditions of COD, total chrome and color removal efficiencies were achieved as 63.3, 99.7, and 82%, respectively. Also, operating costs for both COD and color removals were evaluated as 0.88 $/m3; but for chrome removal, they were 0.70 $/m3. In the case of aluminum electrode, the optimum conditions of COD, total chrome, and color removal were found to be at the fifth level for each operating parameter corresponding to current density (50 mA/cm2), initial pH (7), and electrolysis time (25 min). As a result, the observed removal efficiencies of COD, total chrome, and color under these optimum conditions were 64.4, 99, and 88%, respectively. In addition, operating costs for COD, chrome, and color removals were 0.94 $/m3.

Acknowledgments

This study was supported by project no. (2012-05-02KAP02), YTU- Office of Scientific Research Project Coordination and performed in the laboratories of Environmental Engineering Department, Yildiz Technical University.

Log in via your institution

Log in to Taylor & Francis Online

There are no offers available at the current time.

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.