Impact of chilled ceiling in a high sensible cooling load room with underfloor air distribution

, , , &
Pages 705-715 | Received 07 Oct 2018, Accepted 11 Feb 2019, Published online: 08 Jul 2019
 

Abstract

The use of an underfloor air distribution (UFAD) system integrated with a chilled ceiling (CC) cooling system can provide a potentially advanced heating, ventilation, and air conditioning (HVAC) system with high sensible cooling loads in modern office buildings. In this paper, an experimental study of the impact of CC in a room with a high sensible cooling load with UFAD was performed when the chilled ceiling surface temperature increased from 17.0 to 26.0 °C. The vertical distributions of indoor air temperature, air velocity, and pollutant (CO2) concentration were measured and evaluated by the vertical air temperature difference (VATD), turbulence intensity (TI), and contaminant removal effectiveness (CRE), respectively. The results showed that the average VATD, TI, and CRE were 0.1–0.9 °C, 4–40%, and 0.85–1.19, respectively, when the internal and external sensible cooling loads equal 41.5W/m2. These evaluation indices varied clearly when the internal sensible cooling load increased from 41.5 to 69.5W/m2, whereas they were almost the same when the external sensible cooling load increased from 41.5 to 69.5W/m2. The minimum CRE and air diffusion performance index (ADPI) coincided with the maximum heat removal effectiveness (HRE) under a constant cooling load condition. The results suggest that it is better to balance the energy consumption as well as indoor air quality and thermal comfort in a room with UFAD + CC.

Additional information

Funding

This study was funded by the National Natural Science Foundation of China (Project number: 51408482 & 51808091), the Jiangsu Natural Science Research Project (Project number: SBK2016021215), the Fundamental Research Funds for the Central Universities (Project number: DUT17RC (3)086), and the Doctoral Scientific Research Foundation of Dalian University (Project number: 20172QL020).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 78.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.