33
Views
0
CrossRef citations to date
0
Altmetric
Research Papers

Silicate and silicone removal by pretreatment to prevent membrane fouling in garment washing wastewater treatment

, , &
Pages 69-73 | Received 10 Mar 2014, Accepted 30 Apr 2014, Published online: 18 Jun 2014
 

Abstract

Membrane technology is being increasingly used in reclamation of textile wastewater. High concentration of silicate and silicone auxiliaries in garment washing wastewater can cause detrimental and unbearable fouling on membrane. Chemical pretreatment before membrane separation is feasible to prevent fouling. Experiments of coagulation were conducted to investigate the characteristics of silicate and silicone removal for reclamation of garment washing wastewater. Two precipitants were tested: iron salt TW-19 and calcium oxide. The optimum precipitant dose is 400 ppm TW-19 in combination with 75 ppm calcium oxide with pH = 9·8 for the garment washing wastewater. Polyacrylamide (PAM) as precipitant aid was also tested with optimum precipitant doses. 2 ppm of PAM is helpful to reduce the metal ions concentration to decrease membrane fouling potential.

Acknowledgements

Thanks are due to nnzhaoguan company for supplying the various precipitants and precipitant aids used in research.

Log in via your institution

Log in to Taylor & Francis Online

There are no offers available at the current time.

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.