Intraocular pressure readings obtained through soft contact lenses using four types of tonometer

, , , , &
Pages 1875-1881 | Published online: 05 Oct 2015

Figures & data

Table 1 Subject demographics

Table 2 Intraocular pressure differences in the subjects wearing soft contact lenses compared to that obtained without contact lenses measured using the Goldmann applanation tonometer

Figure 1 Bland–Altman plot showing the relationship between the IOP values of the naked eyes measured using GAT and those obtained while wearing SCLs measured using NCT.

Notes: (A) Wearing −5.00 D SCLs. (B) Wearing −0.50 D SCLs. (C) Wearing +5.00 D SCLs.
Abbreviations: IOP, intraocular pressure; GAT, Goldmann applanation tonometer; SCLs, soft contact lenses; NCT, non-contact tonometer; CL, contact lens; D, diopter.
Figure 1 Bland–Altman plot showing the relationship between the IOP values of the naked eyes measured using GAT and those obtained while wearing SCLs measured using NCT.

Figure 2 Bland–Altman plot showing the relationship between the IOP values of the naked eyes and those obtained while wearing SCLs measured using GAT.

Notes: (A) Wearing −5.00 D SCLs. (B) Wearing −0.50 D SCLs. (C) Wearing +5.00 D SCLs.
Abbreviations: IOP, intraocular pressure; GAT, Goldmann applanation tonometer; SCLs, soft contact lenses; CL, contact lens; D, diopter.
Figure 2 Bland–Altman plot showing the relationship between the IOP values of the naked eyes and those obtained while wearing SCLs measured using GAT.

Figure 3 Bland–Altman plot showing the relationship between the IOP values of the naked eyes measured using GAT and those obtained while wearing SCLs measured using RBT.

Notes: (A) Wearing −5.00 D SCLs. (B) Wearing −0.50 D SCLs. (C) Wearing +5.00 D SCLs.
Abbreviations: IOP, intraocular pressure; GAT, Goldmann applanation tonometer; SCLs, soft contact lenses; CL, contact lens; D, diopter; RBT, iCare rebound tonometer.
Figure 3 Bland–Altman plot showing the relationship between the IOP values of the naked eyes measured using GAT and those obtained while wearing SCLs measured using RBT.

Figure 4 Bland–Altman plot showing the relationship between the IOP values of the naked eyes measured using GAT and those obtained while wearing SCLs measured using the Tono-Pen XL.

Notes: (A) Wearing −5.00 D SCLs. (B) Wearing −0.50 D SCLs. (C) Wearing +5.00 D SCLs.
Abbreviations: IOP, intraocular pressure; GAT, Goldmann applanation tonometer; SCLs, soft contact lenses; CL, contact lens; D, diopter.
Figure 4 Bland–Altman plot showing the relationship between the IOP values of the naked eyes measured using GAT and those obtained while wearing SCLs measured using the Tono-Pen XL.

Table 3 Results of the regression analysis of the intraocular pressure values of the naked eyes measured using the Goldmann applanation tonometer, and those obtained while wearing contact lenses measured with various tonometers