External quality assessment for immunohistochemistry: experiences from NordiQC

Pages 331-340 | Accepted 20 Mar 2015, Published online: 22 Apr 2015
 

Abstract

Immunohistochemistry (IHC) is applied routinely in surgical and clinical pathology, because it is essential for diagnosis and sub-classification of many neoplastic lesions. Despite its extensive use for more than 40 years, lack of standardization is a major problem; many factors during the pre-analytical, analytical and post-analytical phases affect the final results. Nordic immunohistochemical Quality Control (NordiQC) was established in 2003 to evaluate the inter-laboratory consistency of IHC, focusing mainly on the analytical part. More than 26,000 IHC slides have been evaluated during the period 2003–2013; 15 − 300 laboratories have participated in each assessment. Overall, 71% of the staining results assessed have been evaluated as sufficient for diagnostic use, while 29% were judged insufficient. All IHC protocols used for the stained slides submitted to NordiQC have been evaluated by focusing on the technical calibration performed by the laboratories, and specific parameters that gave sufficient or insufficient results have been identified. The most common causes for insufficient results were: inadequate calibration of the primary antibody, use of an inadequate primary antibody, inappropriate choice of epitope retrieval method, insufficient heat induced epitope retrieval (HIER) and use of an inadequate detection kit. Approximately 90% of the insufficient results were characterized by either a signal that was too weak or false negative staining, whereas in the remaining 10%, a poor signal-to-noise ratio or false positive staining was seen. Identification of positive and negative tissue controls to ensure appropriate calibration of the IHC assay combined with individually tailored suggestions for protocol optimization have improved IHC staining for many markers and thus inter-laboratory consistency of the IHC results. The overall data generated by NordiQC during 11 years clearly indicates that external quality assessment is a valuable and necessary supplement to internal quality control.

Declaration of interest: The author reports no conflicts of interest. The author alone is responsible for the content and writing of this paper.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 203.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.