Addressing Assumptions for the Use of Non-invasive Cardiac Output Measurement Techniques During Exercise in COPD

, , , , &

Figures & data

Table 1. Patient characteristics

Table 2. Cardiorespiratory responses to cycle exercise

Figure 1. Cardiac output in COPD derived using various non-invasive techniques. Results consistently show significantly lower measured using N2O-RB as compared to the PaCO2-derived CO2-RB or the bioimpedance approach, at rest as well as for all exercise intensities (*p < 0.05).

End-tidal CO2-derived rebreathing values are also significantly lower than those calculated using direct PaCO2 under all conditions (§p < 0.05); End-tidal CO2-derived rebreathing values are however not statistically different from those obtained using N2O-RB; CO2-RB(PaCO2): Cardiac output () derived from non-inert CO2 gas rebreathing with PaCO2 correction; CO2-RB(PETCO2): Cardiac output () derived from non-inert CO2-RB gas rebreathing without PaCO2 correction; N2O-RB: Cardiac output () derived from inert N2O gas rebreathing; Impedance: Cardiac output () determined by impedance cardiography.

Figure 1. Cardiac output in COPD derived using various non-invasive techniques. Results consistently show significantly lower measured using N2O-RB as compared to the PaCO2-derived CO2-RB or the bioimpedance approach, at rest as well as for all exercise intensities (*p < 0.05).End-tidal CO2-derived rebreathing values are also significantly lower than those calculated using direct PaCO2 under all conditions (§p < 0.05); End-tidal CO2-derived rebreathing values are however not statistically different from those obtained using N2O-RB; CO2-RB(PaCO2): Cardiac output () derived from non-inert CO2 gas rebreathing with PaCO2 correction; CO2-RB(PETCO2): Cardiac output () derived from non-inert CO2-RB gas rebreathing without PaCO2 correction; N2O-RB: Cardiac output () derived from inert N2O gas rebreathing; Impedance: Cardiac output () determined by impedance cardiography.

Figure 2. Cardiac output derived using various non-invasive techniques in healthy subjects measured in our laboratory. Comparison of techniques at rest or at each exercise intensities reveals no statistically significant differences.

CO2-RB(PETCO2): Cardiac output () derived from non-inert CO2-RB gas rebreathing without PaCO2 correction; N2O-RB: Cardiac output () derived from inert N2O gas rebreathing. Impedance: Cardiac output () determined by impedance cardiography.

Figure 2. Cardiac output derived using various non-invasive techniques in healthy subjects measured in our laboratory. Comparison of techniques at rest or at each exercise intensities reveals no statistically significant differences.CO2-RB(PETCO2): Cardiac output () derived from non-inert CO2-RB gas rebreathing without PaCO2 correction; N2O-RB: Cardiac output () derived from inert N2O gas rebreathing. Impedance: Cardiac output () determined by impedance cardiography.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.