Waxy-Maize HES 130/0.4; evidence based clinical decisionsFootnote

, , , , , , , , , , , , , , , , , , , , , & show all
Pages 197-202 | Received 14 Mar 2011, Accepted 17 Apr 2011, Published online: 17 May 2019

Abstract

The profile of an ideal volume substitution solution can be defined by volume effect and safety. The volume effect should be stable and reliable, offer a constant plateau effect and be easily controllable. Many in depth characteristics has been offered by recognized societies [Citation1] and includes: no tissue storage, no plasma accumulation, no influence on haemostasis, no influence on the immune system, no infectivity, no antigenicity, no allergenic potential, no proinflammatory properties, no toxicity, teratogenity or mutagenity, no influence on diagnostic tests, good compatibility with other medication, good tolerance, and complete elimination. Research has shown that it is possible to meet these objectives in the development of hydroxyethyl starches (HES) by optimizing the combination of concentration, the molecular weight, the degree and pattern of substitution. A new starch (HES 130/0.4) has therefore been developed. This new generation of HES offers the same volume effect and duration as the previous standard HES 200/0.5, yet with more favorable pharmacological characteristics and an improved safety profile. The following article is a collection of experts’ opinion from different recognized universities, hospitals and healthcare organizations about the evidence based clinical decisions when using Waxy-Maize HES 130/0.4 (Voluven®) in various clinical situations.

1 When should an anesthetist consider Waxy-Maize HES 130/0.4 usage and why?

Waxy-Maize HES 130/0.4 should be considered for prophylaxis and treatment of hypovolaemic cases being effective plasma volume expander giving 100% volume expansion and with 4–6 plateau effect [Citation2] compared to crystalloids which deliver only 20–30% volume expansion with 30 min duration of expansion. Along with being effective, Waxy-Maize HES 130/0.4 has an excellent safety profile at high dose application reaching 50 mg/kg bw/day in all age groups including children [Citation3Citation8]. Its safety has been proved also in repeated administration [Citation7], and with a highly recognized amount of evidence based literature that reached more than 180 publications along with proven safety records in more than 30 million patients.

2 When should an intensivist consider Waxy-Maize HES 130/0.4 usage and why?

In addition to the previous points, Waxy-Maize HES 130/0.4 would help in reaching an optimized tissue oxygenation and improved microcirculation when compared to crystalloids as established in Lomivorotov [Citation9] and Dubin [Citation10]. Waxy-Maize HES 130/0.4 also helps in reducing inflammatory response and endothelial activation along with the recognized characteristic of the capillary ceiling properties of Waxy-Maize HES 130/0.4 in cases of capillary leakage syndrome with comparison to different fluid regimens [Citation11Citation21] among which is albumin which appeared to be inferior to Waxy-Maize HES 130/0.4 which reduced incidence of pulmonary oedema and improved of the APACHE II score as established by Palumbo [Citation22]. The clear advantage in reduced total fluid administration when using Waxy-Maize HES 130/0.4 also helps in guarding against intra-abdominal hypertension with comparison to crystalloids as in Vidal [Citation23].

3 What are the other benefits for Waxy-Maize HES 130/0.4 usage rather than being a plasma expander?

Waxy-Maize HES 130/0.4 can assist clinician in achieving better tissue oxygenation than crystalloids through improvement of microcirculation while reducing the total fluid administration [Citation9,Citation10,Citation24]. Another benefit is the lower inflammatory response with Waxy-Maize HES 130/0.4 in comparison to crystalloids and albumin by lowering the inflammatory response and endothelial activation [Citation11Citation21]. The improvement of pulmonary functions in comparison to albumin has been established in favor of Waxy-Maize HES 130/0.4 in septic patients [Citation22].

4 What are the advantages that Waxy-Maize HES 130/0.4 brings to clinical practice over older starches?

With Waxy-Maize HES 130/0.4, there is no plasma accumulation even in repetitive high doses as established by Waitzinger [Citation25] and Ellger [Citation5]. Waxy-Maize HES 130/0.4 has very minimal effect on blood coagulation and many evidence based assessment established that with Waxy-Maize HES 130/0.4 there is less blood loss in comparison to Pentastarch which was reviewed by Kozek-Langenecker [Citation26]. Waxy-Maize HES 130/0.4 has a better renal profile even in severe renal impairment even at creatinine clearance close to 15 ml/min as established by Jungheinrich [Citation27]. Waxy-Maize HES 130/0.4 has a maximal daily dose of 50 ml/kg bw/day which is by far higher than older starches such as Hetastarch (20 ml/kg bw/day) and Pentastarch (33 ml/kg bw/day). The FDA has approved Waxy-Maize HES 130/0.4 in treatment and prophylaxis of hypovolaemia in adults, pediatrics and neonates in December 2007 [Citation28].

5 What should be the consensus of Waxy-Maize HES 130/0.4 usage in comparison to albumin and crystalloids?

Albumin has been a choice for treatment of hypovolaemia in critically ill patients until the 1998 Cochran review [Citation29] showed increased mortality when compared to isotonic saline. Then the SAFE study [Citation30] showed that both have the same mortality rates in the ICU settings. Waxy-Maize HES 130/0.4 has capillary sealing properties with less possibility of pulmonary edema than albumin as established by Palumbo [Citation22]. When taking into consideration the high cost of albumin products, Waxy-Maize HES 130/0.4 appears to be more cost-effective than albumin. Another advantage is that Waxy-Maize HES 130/0.4 has a quicker infusion rate than albumin (25 ml/min vs. 5 ml/min) [Citation31]. The availability of Waxy-Maize HES 130/0.4 is better than albumin solutions which have been proved through history of shortage of albumin supply due to donors’ restrictions. The handling of albumin solution is requiring special storage care to avoid alteration of the protein nature of the solution while HES products do not require such restrictions.

In comparison with crystalloids Waxy-Maize HES 130/0.4 has a volume expansion of 100% while crystalloids have only 20–30% effect. The plateau effect of Waxy-Maize HES 130/0.4 with duration of 6 h is more clinically favorable in comparison to crystalloids which have duration of expansion that lasts only 30 min even with hypertonic saline. Waxy-Maize HES 130/0.4 maintains hemodynamics with less volume than crystalloids lowering the morbidity associated with excess volume and with its rheological properties it improves microcirculation and tissue oxygenation resulting in better organ function, while crystalloids worsen it [Citation9,Citation10]. Waxy-Maize HES 130/0.4 reduces inflammatory response and capillary leakage resulting in less edema than different fluid regimens [Citation11Citation22].

Waxy-Maize HES 130/0.4 is more effective than crystalloids in reducing the incidence of hypotension if used as preloading fluid before spinal anesthesia as established by Sucre [Citation32], Ko [Citation33], Barbe [Citation34], Madi-Jebara [Citation35], and Siddik [Citation36].

6 Among starches used in fluid therapy regimens, why Waxy-Maize HES 130/0.4 considered a class of its own?

Waxy-Maize HES 130/0.4 holds the best evidence based medicine among all starches: 10 years of clinical experience, 180 publications, and more than 30 million patients’ usage.

7 Why should we consider Waxy-Maize HES 130/0.4 for a critically ill patient although there are some reports indicating increased risk of acute renal injuries in septic patients when using older starches?

Safety of Waxy-Maize HES 130/0.4 on renal functions has been proved in a lot of critically ill patients in more than 20 clinical trials [Citation7,Citation8,Citation27,Citation37Citation47].

The report of increased AKI is associated with the use of older starches such as Pentastarch 10% (hyperoncotic) and is mostly related to its accumulation [Citation48]. While Waxy-Maize HES 130/0.4 proved to have no accumulation even with renal impairment: with comparison to older starches as in Jungheinrich [Citation27]. Clinicians should always look for the right HES: Waxy-Maize 130/0.4 with reduced molecular weight and reduced molar substitution.

8 What is the role of Waxy-Maize HES 130/0.4 in guarding against intra abdominal hypertension and what is the expected benefit in the ICU setting?

Waxy-Maize HES 130/0.4 reduces total administration of resuscitating fluids (reduce positive fluid balance). A high amount of resuscitating fluids is the major risk factor for increased IAH as established by Vidal [Citation23]. In the ICU as referred by Malbrain [Citation49], patients with IAH (>12 mm) leads to a mortality rate of 38.8% while patients with no IAH had mortality rates of 22.2%.

9 According to the American practice, crystalloids should be the right choice in septic patients in the ICU, why should we consider Waxy-Maize HES 130/0.4 for these patients?

There is no contra-indication of using Waxy-Maize HES 130/0.4 (as a colloid) in any American guidelines. United States experience with Waxy-Maize HES 130/0.4 started very recently: Waxy-Maize HES 130/0.4 FDA approval was in December 2007 [Citation28] while the actual usage started late 2008. There is an increased interest in using Waxy-Maize HES 130/0.4 in the states nowadays with matching reports of its safety and efficacy to the worldwide experience that started more than 10 years ago when Waxy-Maize HES 130/0.4 was launched in Europe. Voluven’s advantages in septic patients includes: capillary ceiling properties in capillary leakage syndrome [Citation11Citation21] reduction of the total fluid administration which will guard against IAH in comparison to crystalloids [Citation23], reduced incidence and severity of oedema [Citation22].

10 There are some publications referring to Waxy-Maize HES 130/0.4 as the right choice for routine preloading before spinal anesthesia while there are some other publications doubting the principle of pre-lauding itself. What do you think is the benefit of using Waxy-Maize HES 130/0.4 in such cases and is it justified to consider Waxy-Maize HES 130/0.4 as the right choice fluid?

There are about 6 clinical trials showing that Waxy-Maize HES 130/0.4 is more efficient compared to crystalloids to prevent hypotension after spinal anesthesia during C-Section [Citation32Citation36]. And there is an ongoing trial named the CAESAR trial also evaluating Waxy-Maize HES 130/0.4 in such cases [Citation50]. The debate of pre-laude or not is yet not conclusive, but there is a pile of evidence supports the prevention of hypotension induced by Spinal Anesthesia when pre-lauding with Waxy-Maize HES 130/0.4 especially that you use half (or even one-third) the amount of crystalloids. Waxy-Maize HES 130/0.4 was referenced as “The right choice for routine Preloading before spinal anesthesia” [Citation33].

11 What is the current clinical experience of Waxy-Maize HES 130/0.4 in pediatric surgery?

Seven published clinical trials studying Waxy-Maize HES 130/0.4 in pediatrics up to 50 ml/kg/day including cardiac surgery and compared to albumin [Citation6,Citation51Citation56].

12 What are the major benefits of Waxy-Maize HES 130/0.4 usage in cardiac surgery?

Benefits in cardiac surgery including using Waxy-Maize HES 130/0.4 as priming solution with comparison to crystalloids and albumin has been established by many authors such as Hengo [Citation57]:

Well characterized plasma volume expansion.

Large volume (50 ml/kg bw/ day).

Minor effects on haemostasis.

Minor influence on renal function.

Relative rapid elimination.

Reduction of endothelial cell activation and inflammatory response.

Minimal risk of anaphylactic reactions.

13 Can Waxy-Maize HES 130/0.4 be considered in burn patients?

In Sudhakar [Citation58] “Waxy-Maize HES 130/0.4 vs. Ringer’s Lactate”, and in Shen [Citation59] results indicate that the optimum quality of circulating blood replenishment and elimination of hypovolaemia are obtained by the use of hydroxyethyl starch 130/0.4 that offers advantages as the rate of blood concentrations and maintenance of volume levels as well as increasing oxygen delivery, resulting in quicker recovery from shock and improvement of burn wound trophism.

14 Is it safe to use Waxy-Maize HES 130/0.4 in transplant surgery?

Waxy-Maize HES 130/0.4 has been used in two Kidney transplant trials (Blasco [Citation40], Pavlidis [Citation45]) and one liver transplant trial (Mukhtar [Citation8]) vs. albumin and it was recommended for routine use.

15 Why is Waxy-Maize HES 130/0.4 better than potato starches even if tetra starch? Does the type of raw material make that difference?

The superiority of Waxy-Maize HES 130/0.4 is obtained from:

Differences in raw materials.

Differences in molecular weight, molar substitution and substitution pattern.

Differences in amylose content and degree of branching (higher amylose/lower branching in potato-starches) [Citation60,Citation61].

Difference of phosphate content (higher in potato-starches) [Citation62].

Incidence of hyperbilirubinemia with potato-starches [Citation63].

Higher number of evidence based literatures in comparison to potato starches which are:

Very few (mostly in vitro studies).

Not comparing safety with colloids such as Waxy-Maize HES 130/0.4 in clinical settings.

16 What is the incidence of anaphylactoid reactions with Waxy-Maize HES 130/0.4?

Of all colloids, hydroxyethyl starch has the lowest rate of allergic reactions documented (approx. 0.06%). Major Anaphylactoid reactions (Grade III and IV) are very rare during HES therapy (Ring and Meßmer, 1977; Laxenaire et al., 1994; Dieterich et al. 1998) [Citation64].

Notes

Peer review under responsibility of Egyptian Society of Anesthesiologists.

References

  • Schoch, T. J. The chemistry of hydroxyethyl starch. Second Conference on Artificial Colloidal Agents. 1963;121–8.
  • M.WestphalM.JamesS.Kozek-LangeneckerR.StockerB.GuidetH.Van AkenHydroxyethyl starches; different products – different effectsAnesthesiology1112009187202
  • P.Van der LindenS.G.De HertD.DeraedtS.CromheeckeK.De DeckerR.De PaepHydroxyethyl starch 130/0.4 versus modified fluid gelatin for volume expansion in cardiac surgery patients: the effects on perioperative bleeding and transfusion needsAnesth Analg1012005629634
  • S.M.KasperP.MeinertS.KampeC.GörgC.GeisenU.MehlhornLarge dose hydroxyethyl starch 130/04 does not increase blood loss and transfusion requirements in coronary artery bypass surgery compared with hydroxyethyl starch 200/05 at recommended dosesAnesthesiology9920034247
  • B.EllgerJ.FreyhoffH.Van AkenM.BookeM.A.MarkusHigh dose volume replacement using HES 130/0.4 during major surgery. Impact on coagulation and incidence of postoperative itchingNeth Tijdschr Anesth1920066368
  • C.HanartM.KhalifeA.De Ville´F.OtteS.De HertP.Van der LindenPerioperative volume replacement in children undergoing cardiac surgery: albumin versus hydroxyethyl starch 130/0.4Crit Care Med372009696701
  • T.A.NeffM.DoelbergC.JungheinrichA.SauerlandD.R.SpahnR.StockerRepetitive large-dose infusion of the novel hydroxyethyl starch 130/0.4 in patients with severe head injuryAnesth Analg96200314531459
  • A.MukhtarF.AboulfetouhG.ObayahM.SalahM.EmamY.KhaterThe safety of modern hydroxyethyl starch in living donor liver transplantation: a comparison with human albuminAnesth Analg10932009924930
  • V.V.LomivorotovV.A.ShmyrevS.M.EfremovEfficiency of using gelofusine and voluven in acute normovolemic haemodilution during cardiosurgical interventionsAnesteziol Reanimatol320081013
  • A.DubinM.PozoC.CasabellaG.MuriasF.PálizasJr.M.MoseincoComparison of 6% hydroxyethyl starch 130/0.4 and saline solution for resuscitation of the microcirculation during the early goal-directed therapy of septic patientsJ Crit Care254201018
  • S.J.ChoiJ.K.ShimS.W.HongComparing the effects of 5% albumin and 6% hydroxyethyl starch 130/0.4 on coagulation and inflammatory response when used as priming solutions for cardiopulmonary bypassMinerva Anestesiol7682010584591
  • C.WangH.JiangZ.ZhangEffects of hydroxyethyl starch 130/0.4 on intraabdominal hypertension in patients with severe acute pancreatitis2009WCACSDublin Ireland
  • J.ZhouJ.Y.ZhongH.LiEffect of 6% hydroxyethyl starch 130/0.4 on renal function in patients undergoing cardiac valve replacement with cardiopulmonary bypassChin J New Drugs Clin Rem7272008504507
  • J.ZhouC.X.YangA.Z.LinHydroxyethyl starch 130/0.4 inhibiting nuclear factor kappa B activity of neutrophils in patients undergoing cardiac valve replacement with cardiopulmonary bypassChin J New Drugs Clin Rem28122009900904
  • B.NohéT.JohannesJ.ReutershanSynthetic colloids attenuate leukocyte-endothelial interactions by inhibition of integrin functionAnesthesiology10342005759767
  • C.A.VoltaV.AlvisM.CampiE.MarangoniR.AlvisM.CastellazziInfluence of different strategies of volume replacement on the activity of matrix metalloproteinases: an in vitro and in vivo studyAnesthesiology106120078591
  • A.Di FilippoM.CiapettiD.PrencipeExperimentally-induced acute lung injury: the protective effect of hydroxyethyl starchAnn Clin Lab Sci3632006345352
  • H.J.DieterichT.WeissmüllerP.RosenbergerEffect of hydroxyethyl starch on vascular leak syndrome and neutrophil accumulation during hypoxiaCrit Care Med346200617751781
  • N.DingH.XiaoLx.XuEffect of hydroxyethyl starch 130/0.4 on ICAM-1 expression in endotoxin-induced acute lung injury in rats and role of MAPK signal pathway in its expressionZongguo Yaolixue Tongbao2532009394398
  • X.FengY.HuJ.DingEarly treatment with hydroxyethyl starch 130/0.4 causes greater inhibition of pulmonary capillary leakage and inflammatory response than treatment instituted later in sepsis induced by cecal ligation and puncture in ratsAnn Clin Lab Sci37120074956
  • X.FengJ.LiuM.YuProtective roles of hydroxyethyl starch 130/0.4 in intestinal inflammatory response and survival in rats challenged with polymicrobial sepsisClin Chim Acta3761–220076067
  • D.PalumboG.ServilloL.D’AmatoM.L.VolpeG.CapogrossoE.De robertisThe effects of hydroxyethyl starch solution in critically ill patientsMinerva Anestesiol722006655664
  • M.G.VidalJ.Ruiz WeisserF.GonzalezIncidence and clinical effects of intra-abdominal hypertension in critically ill patientsCrit Care Med366200818231831
  • T.StandlM.A.BurmeisterF.SchroederE.CurrlinJ.Schulte am EschM.FreitagHydroxyethyl starch (HES) 130/0.4 provides larger and faster increases in tissue oxygen tension in comparison with prehemodilution values than HES 70/0.5 or HES 200/0.5 in volunteers undergoing acute normovolemic hemodilutionAnesth Analg962003936943
  • J.WaitzingerF.BepperlingG.PabstJ.OpitzHydroxyethyl starch (HES) [130/0.4], a new HES specification. Pharmacokinetics and safety after multiple infusions of 10% solution in healthy volunteersDrugs RD42003149157
  • S.A.Kozek-LangeneckerC.JungheinrichW.SauermannP.J.Van der LindenThe effects of hydroxyethyl starch 130/0.4 (6%) on blood loss and use of blood products in major surgery: a pooled analysis of randomized clinical trialsAnesth Analg1072008382390
  • C.JungheinrichR.ScharpfM.WargenauF.BepperlingJ.-F.BaronThe pharmacokinetics and tolerability of an intravenous infusion of the new hydroxyethyl starch 130/0.4 (6%, 50.0 ml) in mild-to-severe renal impairmentAnesth Analg952002544551
  • http://www.fda.gov/bbs/topics/NEWS/2007/NEW01765.html.
  • Cochrane Injuries Group albumin Reviewers. Human albumin administration in critically ill patients: systematic review of randomized controlled trials. Cochrane Injuries Group Albumin Reviewers. BMJ 1998;317:235–40.
  • SAFE Study InvestigatorsS.FinferR.BellomoS.McEvoyEffect of baseline serum albumin concentration on outcome of resuscitation with albumin or saline in patients in intensive care units: analysis of data from the saline versus albumin fluid evaluation (SAFE) studyBMJ33320061044
  • Product information leaflet of HA solution & HES 130/0.4.
  • Sucre MJ, Camino G, Piccolo M, De Nicola A. Effectiveness of volume preload before spinal anaesthesia for caesarean section: 6% hydroxyethyl starch 130/0.4 versus lactated Ringer’s solution. S204, WCA 2004.
  • J.S.KoC.S.KimH.S.ChoD.H.ChoiA randomized trial of crystalloid versus colloid solution for prevention of hypotension during spinal or low-dose combined spinal-epidural anesthesia for elective cesarean deliveryInt J Obstet Anesth162007812
  • Barbe E, Lewi L, De Buck F, Vandermeersch E, Van De Velde M: Combined spinal epidural analgesia during labour: Does prophylactic intravenous colloid infusion reduce the incidence of hypotension? Acta Anaesthesiologica Belgica, 2007;58:2
  • S.Madi-JebaraA.GhosnG.SleilatyF.RichaA.CherfaneF.HaddadPrevention of hypotension after spinal anesthesia for cesarean section 6% hydroxyethyl starch 130/0.4 (Voluven®) versus lactated ringer’s solutionLebanese Med J5642008203
  • S.SiddikV.NasrS.TahaR.ZbeideJ.M.ShehadeA.AlamiA randomized trial comparing colloid preload to coload during spinal anesthesia for elective cesarean deliveryAnesth Analg10942009
  • C.Fenger-EriksenC.Hartig RasmussenT.Kappel JensenE.Anker-MøllerJ.HeslopJ.FrøkiaerRenal effects of hypotensive anaesthesia in combination with acute normovolaemic haemodilution with hydroxyethyl starch 130/0.4 or isotonic salineActa Anaesthesiol Scand492005969974
  • G.GodetJ.J.LehatG.JanvierA.SteibV.de CastroP.CoriatSafety of HES 130/0.4 (Voluven®) in patients with preoperative renal dysfunction undergoing abdominal aortic surgery: a prospective, randomized, controlled, parallel-group multicentre trialEur J Anaesthesiol252008986994
  • A.MahmoodP.GoslingR.K.VohraRCT comparing the effects on renal function of hydroxyethyl starch or gelatine during aortic aneurysm surgeryBr J Surg942007427433
  • Blasco V, Leone M, Antonini F, Geissler A, Albanese J, Martin C. Comparison of the novel hydroxyethylstarch 130/0.4 and hydroxyethylstarch 200/0.6 in brain-dead donor resuscitation on renal function after transplantation. Br J Anaesth BJA 2008 [Advance Access published February 6].
  • Y.Y.DengY.KangX.L.LiaoInfluence of hydroxyethyl starch 130/0.4 on renal function of injured patients with acute renal failure after Wenchuan earthquakeChin Crit Care Med2122009114116
  • J.L.JoverJ.P.GarciáC.MartínezA.EspíE.GregoriJ.AlmagroUse of hydroxyethyl starch (Voluven®) to protect renal function in laparoscopic surgeryRev Esp Anestesiol Reanim5620092730
  • F.SchabinskiJ.OishiF.TucheA.LuyY.SakrD.BredleEffects of a predominantly hydroxyethyl starch (HES)-based and a predominantly non HES-based fluid therapy on renal function in surgical ICU patientsIntensive Care Med359200915391547
  • J.S.OoiA.R.RamzishamM.D.ZamrinIs 6% hydroxyethyl starch 130/0.4 safe in coronary artery bypass graft surgery?Asian Cardiovasc Thorac Ann172009368372
  • M.PavlidisS.PoulouC.PalumbiA.MantziokaK.TsinariSafety of hydroxyethyl starch (HES 130/0.4) in patients undergoing cadaver kidney transplantation Eur J Anaesthesiol. Euroanaesthesia 2009, The European Anaesthesiology CongressMilanJune 6–92009
  • I.KiesowD.PavlovicS.O.KuhnC.LehmannM.WendtVolume replacement therapy with HAES 130/0.4 does not influence rate of renal failure in septic patients InfectionInfection37Suppl. 3200950
  • N.BoussekeyR.DarmonJ.LangloisS.AlfandariP.DevosA.MeybeckResuscitation with low volume hydroxyethylstarch 130 kDa/0.4 is not associated with acute kidney injuryCrit Care1422010R40
  • F.M.BrunkhorstC.EngelF.BloosA.Meier-HellmannM.RagallerN.WeilerIntensive insulin therapy and Pentastarch resuscitation in severe sepsisNew Engl J Med3582008125139
  • M.L.MalbrainD.ChiumelloP.PelosiIncidence and prognosis of intraabdominal hypertension in a mixed population of critically ill patients: a multiple-center epidemiological studyCrit Care Med332005315322
  • <http://www.clinicaltrial.gov/ct2/show/NCT00694343>.
  • M.KhalifeC.HanartA.de VilleS.de HertP.van der Linden6% HES 130/0.4 versus 4% albumin for volume replacement in paediatric cardiac surgery: cyanotic congenital diseaseEur J Anaesthesiol232006A-300
  • H.LochbühlerC.GalliH.HagemannHydroxyethyl starch HES 130/0.4 in paediatric surgery: results of an explorative, controlled, multicenter safety studyCrit Care Med7Suppl. 22003107
  • T.StandlH.LochbuehlerC.GalliA.ReichG.DietrichH.HagemannHES 130/0.4 (Voluven®) or human albumin in children younger than 2 yr undergoing non-cardiac surgery. A prospective, randomized, open label, multicentre trialEur J Anaesthesiol252008437445
  • I.A.SavvinaIntraoperative Voluven® use in paediatric neurosurgical patientsIntensive Care Med29Suppl. 12003604
  • K.C.SungP.K.SukY.M.JaEffects of intravascular volume therapy using hydroxyethyl starch (130/0.4) on post-operative bleeding and transfusion requirements in children undergoing cardiac surgery: a randomized clinical trialActa Anaesthesiol Scand502006108111
  • S.SaudanM.PellegriniD.CeroniHydroxyethyl starch 130/0.4 versus albumin in children undergoing spinal fusion: safety and efficiencyEur J Anaesthesiol23Suppl. 372006A662
  • Haljamae Hengo: perioperative advances in colloid therapy. In: 6th annual NATA symposium, April; 2005.
  • G.V.SudhakarP.LakshmiRole of HES 130/0.4 in resuscitation of patients with major burn injuryTransfus Altern Transfus Med1020084350
  • N.P.ShenV.M.EgorovF.N.BrezginInfusion therapy for burn shock in childrenAnesteziol Reanimatol Anaestesiol Intensive Care12200623
  • W.ThornS.MohazzebMolecular weights, lengths and distribution of side-chains in d-polyglucanesStarch/Stärke42101990373376
  • K.SommermeyerF.CechM.SchmidtKlinisch verwendete Hydroxyethylstärke: Physikalisch-chemische CharakterisierungKrankenhauspharmazie81987271278
  • A.BlennowS.B.EngelsenL.MuncStarch molecular structure and phosphorylation investigated by a combined chromatographic and chemometric approachCarbohydr Polym412000163174
  • O.SanderK.ReinhartA.Meier-HelmannEquivalence of hydroxyethyl starch HES 130/0.4 and HES 200/0.5 for perioperative volume replacement in major gynaecological surgeryActa Anaesthesiol Scand47200311511158
  • M.LaxenaireC.CharpentierL.FeldmanLe Group Francais d’Etude, de la Tole´rance des Substituts Plasmatiques: anaphylactoid reactions to colloid plasma substitutes: frequency, risk factors, mechanisms. A French multicenter prospective studyAnn Fr Anesth Re´anim131994301310