165
Views
22
CrossRef citations to date
0
Altmetric
Original Articles

Development of SYBR‐Green Real‐Time PCR and a Multichannel Electrochemical Immunosensor for Specific Detection of Salmonella enterica

, , , , &
Pages 1611-1625 | Received 15 Dec 2005, Accepted 20 Feb 2006, Published online: 23 Aug 2007
 

Abstract

The objective of the present work was to develop and evaluate an SYBR Green real time polymerase chain reaction (PCR) method for the specific detection of Salmonella spp in broth cultures and meat samples experimentally contaminated. Also, a simple and rapid multichannel electrochemical immunosensor (MEI) for this pathogen is under study.

The PCR was carried out using primers ttr6 and ttr4 for the amplification of a highly conserved DNA region (ttr sequence) specific for all Salmonella serovars.

A boiling step, for the extraction of DNA, was combined with a real time PCR method based on the double‐stranded DNA (dsDNA) binding dye SYBR Green. The standard curve constructed using the mean threshold cycle and various concentrations of S. enteritidis (ranging fron 102 to 108 CFU mL−1) showed good linearity (R2=0.999) with the minimum level of detection of 102 CFU mL−1. The experiments were conducted analyzing 30 Salmonella strains and 20 non‐Salmonella strains. All Salmonella serotypes tested were ttr‐positive and all other bacteria yielded no amplification products. The specificity of the reaction was confirmed by the melting temperature (Tm) of the amplicon obtained (Tm=80.1±0.1).

To verify the effectiveness of the assay, experiments were conducted on experimentally contaminated samples, which were also analyzed for comparison by the standard cultural method.

A multichannel electrochemical immunosensor for detection of Salmonella also was developed. It consists of a disposable screen‐printed sensor array, coupled with a multichannel pulse monitor, which was assembled as an immunosensor through the use of specific monoclonal (MAb) and polyclonal (PAb) antibodies in a sandwich format. The limit of detection was calculated to be 2×106 UFC mL−1 with a working range between 5×106 to 5×108 UFC mL−1 and a total analysis time of about 3 h. This immunoelectrochemical system is economical, rapid, and easy to use but it is still under development in order to improve its analytical performance.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 768.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.