Abstract
A rapid chemiluminescence (CL) reaction was observed when Ce(IV) was injected into the mixed solution of pyridoxine hydrochloride and sodium sulfite. A new flow-injection CL method for the determination of pyridoxine hydrochloride was established. The detection limit (3σ) was 0.5 mg/L pyridoxine hydrochloride and the relative standard deviation (RSD) was 3.3% (n = 11, γ = 5 mg/L). The CL intensity responded linearly to the concentration of pyridoxine hydrochloride in the ranges 1.0–10.0 mg/L and 10.0–100.0 mg/L with linear correlation coefficients of 0.9994 and 0.9991, respectively. The method had been applied to the determination of pyridoxine hydrochloride in tablets and injections successfully.
Acknowledgments
This paper was submitted as part of a Special Issue on Flow Injection Analysis.
The authors gratefully acknowledge the equipment and reagent support from Professor Shunfu Dong and Pharmacy Department of Jilin Medical College.
Notes
δa and δb are S.D. for coefficients a and b (n = 3).
a Average of three measurements.