143
Views
1
CrossRef citations to date
0
Altmetric
ATOMIC SPECTROSCOPY

Determination of Lead at Trace Level Through Cloud Point Extraction and Atomic Absorption Spectrometry with Electrothermal Atomization: An Environmentally Benign Methodology

, , &
Pages 2421-2429 | Received 17 Jan 2013, Accepted 11 Apr 2013, Published online: 16 Sep 2013
 

Abstract

The quantification of lead in water samples is presented at the sub-ppb level through preconcentration with cloud point extraction (using Triton x-100 and eriochrome black T) and atomic absorption spectrometry with electrothermal atomization. In order to study the influence of several variables, experimental design analyses were carried out. Linearity was observed between 0.15 to 1.20 ng mL−1 (r = 0.98), with a detection limit of 0.04 ng mL−1 and a quantification limit of 0.15 ng mL−1. A mean recovery of 90 ± 9% (n = 6, P = 0.05) was found; at the precision was 9% expressed as the coefficient of variation. Anions and cations that were studied did not affect the recovery of lead. Water samples of different sources were analyzed directly as well as by the standard addition method; no statistical differences were found between the two procedures. Finally, the present methodology was compared with liquid–liquid extraction of the lead-ditizone complex, using green analytical indicators proposed for this purpose.

Acknowledgments

The authors acknowledge the financial support provided by the SEP in Mexico ((PROMEP/1035/10/5489) for the achievement of this work.

Notes

a Pearson values (P) lower than 0.05 showed significant differences at a 95% confidence level.

a Pearson values (P) lower than 0.05 showed significant differences at a 95% confidence level.

a Pearson values (P) lower than 0.05 showed significant differences at a 95% confidence level.

a Standard deviation of the blank, 2.6 × 10−3.

b Coefficient of variation under repeatability conditions.

c Expressed as the mean recovery ± confidence limits (α = 0.05).

Note. All concentrations in ng mL−1.

a Standard error according to Bruce and Gill Citation1999.

a E Factor: includes volume of sample.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 768.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.