271
Views
10
CrossRef citations to date
0
Altmetric
Original Articles

Radiative Heat Transfer Through the Fuel-Rich Core of Laboratory-Scale Pool Fires

&
Pages 475-489 | Received 15 May 2013, Accepted 19 Nov 2013, Published online: 23 Apr 2014
 

Abstract

Radiative heat transfer calculations are conducted along the axis of six axisymmetric pool fires by using the “exact” line-by-line (LBL) method, the narrow band correlated k (NBCK) model, the full-spectrum correlated k (FSCK) model, the multi-scale full-spectrum k-distribution (MSFSK) model, and the wide-band model implemented in the fire dynamic simulator (FDS). The two baseline cases correspond to 34 kW and 176 kW methane pool fires generated on a burner of 0.38 m diameter. For each heat release rate, two other moderately and heavily sooting pool fires were generated by considering higher soot volume fractions while keeping temperature and gaseous species concentrations unaltered. For each radiative model, the corresponding absorption coefficients for carbon dioxide, water vapor, carbon monoxide, and methane were generated from the same high-resolution spectroscopic databases. Model results show that the contribution of carbon monoxide to the radiative intensity can be neglected, whereas that of methane increases with the heat release rate (HRR) and decreases as the soot loading increases. It is also found that the gray approximation for soot holds for the 34 kW pool fires and the weakly and moderately sooting 176 kW pool fires but ceases to be valid for the heavily sooting 176 kW pool fire. Concerning the accuracy of the different approximate radiative models, comparisons with the LBL solutions show that the NBCK model can be used as a reference if LBL solutions are not available. On the other hand, the FDS wide-band model fails in predicting accurately the radiative intensity through the fuel-rich core of pool fires. Finally, the FSCK provide predictions within 10% of LBL solutions with the exception of the heavily sooting 176 kW pool fire where the strong attenuation of radiation by methane invalidates the “correlated” assumption of the absorption coefficient. In this case, the MSFSK model must be considered, improving substantially the predictions of the FSCK.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 1,493.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.