Assessment of Ionic Interferences to Nitrate and Potassium Analyses with Ion-Selective Electrodes

, , , , &
Pages 1750-1768 | Received 01 Dec 2008, Accepted 28 Sep 2009, Published online: 14 Jul 2010
 

Abstract

Ion-selective electrodes (ISEs) are simple tools used for rapid measurement of nitrate nitrogen (NO3-N) and potassium (K) concentrations in plant sap. With the development of best management practices (BMPs), interest exists in using ISEs for soil leachate and soil and fertilizer solutions. Nitrate N and K concentrations in the 0 to 10,000 mg L–1 ISE working range were measured in diluted solutions of common salts to assess ionic interference of calcium (Ca2+), ammonium (NH4 +), chloride (Cl), and sulfate (SO4 2–). The effects of meter (replication) were unexpectedly significant in one out of three ranges for NO3-N and K (P values of 0.50, 0.72, and 0.01 for NO3-N and 0.99, 0.01, and 0.74 for K, for the 0–100, 100–1,000 and 1,000–10,000 mg L–1 ranges, respectively). The responses of calculated NO3-N and K concentrations to measured NO3-N and K concentrations were linear, but slopes ranged from 0.85 to 1.54, from 0.24 to 2.72, and from 0.93 to 5.48 for NO3-N and from 0.80 to 1.01, from 0.71 to 1.39, and from 0.93 to 2.21 for K for the 0–100, 100–1,000, and 1,000–10,000 mg L–1 measuring ranges, respectively. All slopes were significantly different from zero, and several were significantly different from each other and the 1:1 line. Pairwise slope comparisons conducted with covariance analysis showed that SO4 2– alone interfered with NO3-N measurements at concentrations ranging from 34 to 171 mg L–1, which was less than the manufacturer's information, and by its presence in combination with K+, NH4 +, Ca2+, and Cl within the medium and high concentration ranges. Potassium measurements were not subject to interference from the ions tested for all three concentration ranges. These results highlight the importance of using quality assurance / quality control (QA/QC) samples in the set of unknown samples to detect inacceptable departure from linearity in routine analysis. The increase in measurement variability from one range to the next showed the importance of keeping measurements within a single concentration range by using dilutions. Hence, ISEs may be used for field measurements of NO3-N and K concentrations in soil leachate as well as soil and nutrient solutions and are therefore a practical BMP tool. However, ISEs should not be used as substitutes for the laboratory methods when official measurements are needed.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 408.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.