Interlaboratory and Intralaboratory Testing of Soil Sulfate Analysis in Mollisols of the Pampas

, , &
Pages 2535-2543 | Received 07 Jan 2011, Accepted 14 Mar 2012, Published online: 27 Sep 2012
 

Abstract

Sulfur (S) deficiencies in grain and forage crops have been detected in many agricultural regions of the world, but soil tests are not commonly used as the basis for S fertilizer recommendation programs. Errors of measurements of soil sulfate were determined to assess whether the variation among and within soil-testing laboratories could be a factor that prevent the adoption of soil testing to assess soil sulfate availability. Subsamples of 10 selected soils (Mollisols) from the Pampas (Argentina) were sent in two batches to five soil-testing laboratories. Laboratories were unaware of the existence of subsamples and performed routine sulfate analysis as if these soils came from 60 different fields. Soil sulfate ranged from 3.3 to 20.6 mg kg−1. One laboratory reported sulfate values greater than the other ones, having a mean bias of 4.1 mg kg−1 S sulfate (SO4). The other four laboratories reported similar sulfate values when soils had low sulfate availability (less than 10 mg S kg−1), even when they used different extractants. Considering only these four laboratories, average interlaboratory coefficients of variations ranged from 6 to 24% for the 10 soils. Within-laboratory mean coefficients of variation (CVs) ranged from 12 to 22%. However, mean absolute errors of all laboratories were less than 1.2 mg kg−1 S-SO4. Two laboratories reported different sulfate values for the two batches of shipment (an average difference of 4.7 and 3.8 mg kg−1 of S-SO4). Laboratories using different extractants obtained similar results, suggesting that using the same extractant is not a prerequisite to standardize laboratory results in these soils. Differences between laboratories in our study were smaller than in other interlaboratory comparisons for soil sulfate. These differences could be easily detected and corrected if laboratories participate in an interlaboratory control system. The observed low mean absolute errors suggested that, in general, all laboratories achieve acceptable precision when evaluating within the same batch of determinations. Differences between batches of shipment (within laboratory error) stressed the importance of using reference material for internal quality control.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 408.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.