Opportunities to overcome underutilization of enhanced insulin delivery technologies in people with type 2 diabetes: a narrative review

ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon & ORCID Icon
Pages 246-254 | Received 16 Aug 2023, Accepted 06 Mar 2024, Published online: 21 Mar 2024

ABSTRACT

Use of innovative technologies such as continuous glucose monitoring (CGM) and insulin delivery systems have been shown to be safe and effective in helping patients with diabetes achieve significantly improved glycemic outcomes compared to their previous therapies. However, these technologies are underutilized in many primary care practices. This narrative review discusses some of the clinical and economic benefits of tubeless insulin delivery devices and discusses how this technology can overcome the main obstacles inherent to use of conventional insulin delivery devices.

1. Introduction

Despite the availability of innovative technologies such as continuous glucose monitoring (CGM) and insulin delivery systems (conventional and tubeless devices), these technologies are mostly underutilized in primary care settings, where the majority of individuals with T2D receive their diabetes care [Citation1]. In a recent online survey of 100 US endocrinologists and 102 primary care physicians (PCPs), 87.0% of endocrinologists reported using CGM compared with only 28.4% of PCPs with their T2D patients [Citation2]. Although use of conventional insulin pumps among endocrinologists and PCPs was fairly similar (83.0% vs. 73.5%, respectively), whether these PCPs actually started patients with diabetes (PwD) on an insulin pump or are simply providing care for PwD who were started by an endocrinologist was not reported. However, use of tubeless insulin delivery devices was lower among both endocrinologists and PCPs, with significantly lower utilization in primary care (56.0% vs. 22.6%, respectively).

This narrative review discusses some of the clinical and economic benefits of tubeless insulin delivery devices and discusses how this technology can overcome the main obstacles inherent to use of conventional insulin delivery devices.

2. Rationale for efforts to improve medication taking behaviors

An estimated 537 million people, worldwide, have diabetes [Citation3]. This includes more than 30 million people with insulin-treated type 2 diabetes (T2D) [Citation4]. Although achieving and maintaining established glycemic targets is necessary to reduce the incidence of acute glycemic events and the development of long-term microvascular and macrovascular complications [Citation5,Citation6]. a substantial proportion of people with diabetes are not achieving their glycemic goals.

The most recent US data show that the percentage of people with T2D with HbA1c <7.0% declined from 57.4% to 50.5% from 2010 through 2014 [Citation7].

The major driver to the prevalence of suboptimal glycemic control is failure to intensify therapy when clinically indicated, a phenomenon that is referred to as therapeutic inertia [Citation8]. The causes of therapeutic inertia are multifactorial and significantly impact glycemic management among insulin-treated PwD. Delays in initiating and intensifying diabetes treatment, especially insulin therapy, have been well documented [Citation9]. However, delays in transitioning from basal only therapy to multiple daily insulin injections (MDI) when needed are most concerning [Citation9]. In a recent analysis of 225,135 T2D patients with insurance claims for an oral antidiabetes medication (OAD) (n = 188,230), basal insulin (n = 23,724), or MDI (n = 13,181), Brixner et al. reported notably higher HbA1c levels among MDI users (8.7%) compared with those treated with OAD (7.0%) and basal insulin (8.4%) [Citation10]. Among PwD with HbA1c ≥9.0% the percentage of those treated with MDI was higher than PwD treated with basal insulin only and OAD (40%, 32%, and 8%, respectively). Among PwD with HbA1c levels 8.0% to <9.0%, the percentage of those treated with MDI (45%) was also notably higher compared with individuals treated with OAD (29%) but similar to those treated with basal insulin (46%). Within the full cohort, the differences in treatment modalities were reflected in the total direct medical costs and diabetes-related medical costs for outpatient care, emergency department services, and inpatient hospitalizations. The total and diabetes-related per annum costs were notably higher for MDI users ($17,185 and $8,278, respectively) versus OAD ($7,217 and $3,005, respectively) and basal insulin ($9,820 and $4,713, respectively).

One factor that contributes heavily to therapeutic inertia is suboptimal adherence to prescribed medication and self-management, particularly among PwD who are treated with MDI [Citation11]. Although PwD are often thought to lack motivation when glucose is poorly controlled, several factors must be considered, such as ‘psychological insulin resistance’ [Citation12]. Resistance to initiating or intensifying insulin therapy is often affected by the attitudes and beliefs held by PwD, including fear of hypoglycemia, potential harm (e.g. blindness), belief that taking insulin means their diabetes is getting worse, anticipated pain of injections, low confidence in their ability to safely use insulin, and that insulin therapy will be too restrictive [Citation12]. None of these factors suggest lack of motivation. Other factors often out of the patient’s control, such as psychological conditions (e.g. depression, distress, anxiety) [Citation13], absence of social support [Citation14], cognitive impairment due to advanced age [Citation15], and even trypanophobia (fear of needles), which is common in children and adults [Citation16], create barriers to adherence.

Another factor is the array of clinician-related barriers. Main barriers include insufficient time, work overload, lack of awareness of clinical guidelines, unfamiliarity with basal-bolus therapy, potential implicit biases, uncertainty about patient adherence, and concern about hypoglycemia [Citation17]. In a global survey of 1,250 clinicians, 75.5% reported that they would treat more aggressively were it not for the risk of hypoglycemia with insulin therapy [Citation17].

The availability of glucagon-like peptide-1 receptor agonist (GLP-1 RA) formulations has reduced some of this burden. Treatment with these medications has low hypoglycemia risk and is now the preferred initial approach to lowering HbA1c if injectable therapy is needed [Citation18]. Moreover, when addition of basal insulin is required, GLP-1 therapy often results in lower basal insulin dosages [Citation19]. However, this option may not be appropriate or acceptable for a minority of PwD. Some PwD may not be willing to tolerate the side effects (e.g. gastrointestinal) [Citation20], whereas others may not be able to afford these medications due to coverage issues or socioeconomic status. Moreover, in real-world use, discontinuation rates are much higher than reported in randomized trials [Citation21].

3. Barriers to conventional insulin pump adoption

Use of insulin pump therapy in individuals with T2D has been shown to lower HbA1c [Citation22], reduce bodyweight [Citation22], increase treatment satisfaction [Citation22], and improve quality of life [Citation23], all of which are important predictors of adherence to treatment [Citation24]. Although the benefits of conventional insulin pump use in this population have been clearly demonstrated, the most recent data estimates that only approximately 35,000 T2D patients were using conventional insulin pump therapy in 2016 [Citation25]. The underutilization of conventional insulin pump therapy can be linked to several factors.

3.1. PwD perceptions

In a survey of 1,503 T1D, investigators identified barriers associated with use of various diabetes devices [Citation26]. Among the 73 insulin pump users, the most common barriers reported were: dislike having a device on their bodies (45.8%) followed by ‘discomfort/pain’ (20.8%), cost of supplies (20.8%), ‘did not trust the device’ (20.8%), ‘difficulty in getting the device to work correctly’ (16.7%), ‘cost of the device’ (13.9%), and ‘caused other people to ask too many questions about their diabetes’ (12.5%). It is reasonable to assume that these barriers may also be issues of concern for individuals with T2D [Citation27].

3.2. Clinician perceptions of patient acceptance

Endocrinologists/diabetes specialists are the main prescribers of most diabetes technologies and play a primary role in encouraging use of diabetes devices. As such, their perceptions of the necessity and feasibility of using insulin pumps for PwD with T2D is highly influential. In a study by Tanenbaum et al., investigators surveyed 209 healthcare professionals to obtain their opinions regarding the main barriers in their T1D PwD’ use of insulin pumps and other devices [Citation28]. Apart from cost and lack of insurance coverage, which were considered to be unmodifiable, the most common barriers cited by respondents were their perceptions that PwD do not like to wear a device (73%), PwD do not like the number of pump alarms (40.7%), and PwD lack understanding of how to use the pump features and/or what to do with the information (42%). Again, we assume that healthcare providers likely have the same perceptions regarding their T2D PwDs.

3.3. Potential for implicit bias

Studies have revealed notably lower utilization of insulin pumps and other diabetes technologies adolescent and adult T1D populations [Citation29–32]. In an observational study of 300 young T1D PwD (age 18–28 years), Agarwal et al. observed that insulin pump use was notably higher among White PwD (72%) compared with Black PwD (18%) [Citation30]. Similar findings were reported by Fantasia et al. in a cohort of 227 adult T2D PwD who received care at an urban safety-net endocrinology clinic. Investigators found a higher percentage of White PwD (55%) used insulin pumps and/or CGM compared with Black PwD (21%) and Hispanic PwD (28%) [Citation29].

In an analysis of the 5,145 T2D adults who participated in the Look AHEAD trial [Citation33], race/ethnicity was significantly associated with use of newer diabetes medications (p = .019) over the median follow-up of 8.3 years. Among the 2,211 PwD, a higher percentage of White PwD (48.0%) initiated therapy with a newer medication compared with Black (44.2%) and Hispanic (41.4%) PwD. Gender disparities in prescription of medications have also been reported by Zhang et al., who found that a significantly lower percentage of women were prescribed a lipid-lowering medication than men (38.1% vs. 48.2%, p < 0.001) [Citation34].

3.4. Access to specialists

Because insulin pumps are prescribed mostly by endocrinologists [Citation2,Citation35], the majority of individuals with T2D may not have ready access to this technology. The most recent data show that there are only approximately 8,500 practicing endocrinologists in the US, and many of these clinicians focus on other diseases (e.g. thyroid, pituitary) [Citation36]. As recently reported by Oser et al., more than 75% of US counties have no endocrinologists; whereas 96% of US counties have at least one primary care physician [Citation37]. Moreover, the shortage of endocrinologists is an increasing concern nationwide will make it increasingly difficult for PwD to receive care from an endocrinologist. It has been predicted that the shortage of adult endocrinologists will increase to ~ 2700 by 2025 [Citation38]. Access to specialists and newer diabetes medications can also by impacted by socioeconomic status. In interviews with 28 T1D patients and six healthcare providers, Scott et al. found that PwD from lower socioeconomic areas were unable to access hospital-based services because they lacked the ability to navigate the healthcare system [Citation39].

3.5. Cost

The cost of insulin pump therapy remains a major barrier for many individuals with diabetes [Citation26], particularly in those of lower socioeconomic status or on fixed incomes. This is particularly relevant to those enrolled in Medicare, the US federal health insurance program that covers primarily people 65 years of age or older. As reported in a recent article by Aleppo et al., Medicare coverage eligibility criteria for insulin conventional pumps are also restrictive, creating barriers to beneficiaries who could benefit [Citation40]. However, unlike conventional insulin pumps, which are covered by Medicare Part B as durable medical equipment, disposable tubeless insulin delivery devices are covered by Medicare Part D.

Coverage policies for insulin pumps under Medicaid, the US joint federal and state health care program for low-income individuals, vary by state [Citation41]. According to a 2022 report, among the 40 US States and the District of Columbia that provide coverage, 20 cover CGMs as a durable medical equipment (DME) benefit and 21 cover CGMs as a pharmacy benefit [Citation41]. Although commercial healthcare coverage of diabetes technologies, in general, is more prevalent than with public insurers, many commercial insurers follow the same eligibility criteria as Medicare.

3.6. Time/resource constraints

Incorporating devices such as insulin pumps into clinical practices requires practices to establish a multidisciplinary team of diabetes specialists who are trained in the functionality and limitation of all current insulin pump systems and can deliver comprehensive training/education to PwD. Importantly, team members must have expertise in interpreting the data and making appropriate treatment adjustments [Citation42]. While many endocrinology practices are staffed to provide this level of care and expertise, most primary care practices are not.

In a survey by Grunberger et al., 202 clinicians (primary care, n = 102; endocrinology, n = 100) ranked the major barriers to using insulin pumps in their patients with T2D [Citation2]. Investigators administered a 7-item questionnaire that queried participants about their current practices, comfort level, and perspectives on use of diabetes technologies. The possible weighted rank score ranged from 4.04 to 48.48. Identified barriers with the highest weighted-rank scores were complexity of the device (16.12), extra office time requirement (14.27), difficulty in training/monitoring PwD (14.24), patient acceptance (13.79), and extra resources requirement (13.19).

3.7. Experience with insulin pumps in primary care

Among many primary care providers, inexperience with insulin pumps and other diabetes devices is a key obstacle to adopting these technologies in their practices. A recent study by O’Donovan et al. assessed the willingness of primary care physicians to prescribe advanced diabetes technologies through a cross-sectional survey of 76 PCPs from 4 geographically diverse centers [Citation43]. Participants included 45 (63%) physicians, 22 (31%) residents, 4 (6%) nurse practitioners, and 1 (1%) clinical pharmacist. The majority (88%) of respondents reported being uncomfortable initiating (88%) or adjusting (89%) conventional insulin pump therapy for PwD withT2D.

In a survey of 41 rural clinic healthcare providers in the northeast US is only 47.4% reported that they use any diabetes devices, citing the need for additional medical team expertise in order to adopt insulin pumps and/or CGMs [Citation44]. Investigators concluded that lack of experience among providers and having PwD managed remotely by out-of-area specialists were the main reasons for not using diabetes devices.

4. Tubeless insulin delivery devices address the barriers inherent to conventional insulin pumps

4.1. Simpler technology

Because use of insulin pumps can mitigate many of the obstacles associated with MDI therapy while improving clinical and economic outcomes, an increasing number of individuals with T2D are using this technology, and the first pumps designed specifically for this population are now available [Citation45]. Moreover, these new devices may be extremely valuable in transitioning PwD treated with basal insulin to basal-bolus therapy.

A key contributor to many T2D patients’ dissatisfaction and frustration with conventional insulin pumps is the inclusion of advanced features that enable PwD to utilize multiple bolus insulin configurations and basal infusion rates. Although these features can be extremely useful for individuals with T1D, they add a level of complexity that is often unnecessary for effective management of T2D [Citation46]. Many T2D patients can achieve good glycemic control with only one or two daily basal rates [Citation47].

Tubeless insulin delivery devices represent a new generation of insulin delivery technologies. Currently there are three categories of these devices available in the US market: wearable patch (e.g. CeQur Simplicity™), once-daily wearable (e.g. V-GO®), and tubeless insulin pump devices (Omnipod DASH®, Omnipod® 5). These devices attach directly to the skin without external tubing; insulin is infused through a short canula into the interstitial tissue [Citation48]. Some of these devices use prefilled insulin cartridges such as the battery-operated Sigi™ patch device (currently under development) [Citation49]; however, most require users to manually fill the insulin reservoir.

The on-body tubeless devices are available with varying features and functionalities. Devices, such as the CeQur Simplicity (US) and PaQ (Europe) devices, are fully mechanical and used mainly as a replacement for insulin pen therapy. Users manually administer their insulin by using buttons located on the device to deliver rapid-acting analog for mealtime coverage and correction dosages; however, injections are still required for basal insulin coverage. The spring-operated V-Go delivery systems (Mannkind Corporation) are fully disposable and are available with pre-set 20 unit, 30 unit, and 40 unit basal dosing capability per day with an additional 36-unit reservoir on all 3 devices for manual, on-demand bolus dosing in 2-unit increments per 24-hour periods. The Omnipod Dash system is simply sensor augmented, whereas the Omnipod 5 Automated Insulin Delivery system (Insulet Corporation) automatically adjusts insulin infusion based on CGM data, residual insulin, and other inputs. Both systems enable users to program their bolus dosages and basal insulin infusion rates, utilizing a separate hand-held controller to deliver the insulin and provide information about ‘insulin-on-board’ to help users avoid unsafe correction bolusing. With the Omnipod 5, infusion of basal can be automatically delivered based on CGM data from the sensor. However, administration of both prandial and correction bolus doses must be programmed by the user. Similar to conventional insulin pumps, full set-up of infusion rates is required.

Among the key advantages to tubeless devices is that they eliminate potential risks of tubing kinks or dislocation, which can interrupt insulin delivery [Citation50]. Another advantage is ease of use and simple handling [Citation26], which, in turn, simplifies education and training [Citation51]. Because the devices are smaller than conventional insulin pumps and can be worn under clothing [Citation26], insulin administration is discreet. Moreover, tubeless devices are often less costly than conventional pumps [Citation45,Citation51].

However, there are disadvantages that should be considered. Unlike conventional insulin pumps, simplified tubeless devices might not be able to track insulin-on-board, which can lead to ‘stacking’ of correction insulin doses and the potential for hypoglycemia [Citation45]. Also, because some simplified devices require users to push one or two buttons to administer their bolus doses, there is the possibility that they could lose track of the amount of insulin being delivered [Citation52]. Inaccuracies in insulin delivery have been reported in some full feature tubeless devices, particularly at low insulin doses [Citation53]. Because the infusion site is not visible, users are not able to see if the cannula has dislodged and infection may not be readily detected [Citation54]. Unlike conventional insulin pumps, the tubeless devices can be worn when exercising, swimming or showering. However, if they are removed for any reason, they must be replaced with a fresh device, and any remaining insulin is wasted whenever the device is changed [Citation55]. Also, as with conventional insulin pumps, there is the possibility the device can become dislocated from the infusion site, and skin problems such as inflammation or allergic contact dermatitis due to either the insertion or the adhesive fixing of the device can occur. Many PwD use protective tapes or glues under the device to prevent skin reactions [Citation56].

4.2. Significant advantages over MDI

Studies have consistently shown significant advantages of tubeless insulin delivery devices over MDI therapy, including improved glycemic control [Citation57–66], reductions in total daily insulin doses (TDD) [Citation56–60,Citation65], reductions in frequency and severity of hypoglycemia [Citation64], greater treatment satisfaction and reduced diabetes burden [Citation57,Citation64,Citation67,Citation68], and cost savings [Citation57–59,Citation65,Citation68] ().

Table 1. Recent studies of on body insulin delivery device and tubeless insulin pump therapy in T2D.

Both single-arm and comparative studies demonstrated that use of tubeless devices resulted in significant improvements in HbA1c, ranging from −0.64% [Citation60] to −1.98% [Citation59], with significant reductions in TDD [Citation57,Citation59,Citation65,Citation66,Citation71] Although some studies have concluded that the cost of tubeless devices tends to be higher than MDI therapy [Citation45,Citation72], use of some devices (e.g. the V-Go device) were associated with significant cost-savings [Citation59,Citation66].

In a prospective, pragmatic trial that evaluated use of the V-Go device in 169 T2D adults, Cziraky et al. reported reductions in cost per day (p=0.006) among V-Go users ($30.59) compared with PwD treated with MDI ($32.20) [Citation70]. V-Go use also show greater cost-effectiveness per 1.0% reduction in HbA1c ($24.02 vs. $58.86, respectively).

Importantly, notable improvements in treatment satisfaction and PwD acceptance of tubeless devices were observed in many of the studies [Citation61,Citation68,Citation71]. Survey results associated with the CeQur Simplicity tubeless insulin delivery device showed significant increases in respondents’ overall treatment satisfaction, less diabetes burden, and improvements in psychological well-being compared with their prior insulin delivery method [Citation68].

Additionally, results from a retrospective study of 3,592 T2D adults revealed distinct differences between prior MDI and conventional pump users regarding their reasons for switching to a tubeless device (Omnipod/Omnipod DASH) [Citation71]. Among the most common reasons from switching to the tubeless device reported by participants were ‘better glycemic control’ (25%), ‘did not want to be tethered to tubing’ (24%), ‘replace the discomfort and hassle of injecting’ 16%), and ‘replace MDI and provide greater flexibility in eating and exercise’ (12%). Clinicians may find these findings useful when discussing use of this technology with their PwD.

5. Summary

Although use of MDI is the most common insulin delivery method in T2D patients who are treated with basal-bolus therapy, adherence and persistency to therapy is often suboptimal and can result in poor outcomes, higher costs and increased healthcare resource utilization [Citation73,Citation74]. The complexity of MDI therapy has been shown to be a key contributor to poor adherence, which, in turn, correlates with PwD perceptions of regimen inflexibility and a burden on daily life [Citation11]. While use of conventional insulin pumps in this T2D population provides significantly better glycemic control compared to MDI therapy [Citation22–24]; many PwD and their healthcare providers are still reluctant to utilize this technology due to several factors, including an unwillingness to be tethered to a device, hinderance of daily activities, social stigma, device complexity, and training requirements [Citation75].

The concept behind tubeless insulin delivery devices is to provide intensively treated T2D patients with a safe, effective, and easy to use alternative to MDI and conventional insulin pump therapy. Recent studies have clearly demonstrated statistically significant reductions in HbA1c and TDD [Citation57,Citation59,Citation61,Citation64,Citation66,Citation71], with increased treatment satisfaction and notable PwD acceptance [Citation61,Citation68,Citation71]. Moreover, reductions in TDD [Citation57,Citation59,Citation65,Citation66,Citation71] and reported cost-savings associated with tubeless devices [Citation59,Citation66] may support greater acceptance of this technology among payers.

Most commercial insurers are beginning to recognize the clinical and economic benefits of tubeless devices in the T2D population; however, Medicaid coverage remains suboptimal. It is well understood that lower socioeconomic status is a strong predictor for the development of diabetes, diabetes-related complications, and mortality [Citation76]. Moreover, a recent US population-based analysis found that Black PwD had lower odds of achieving a composite diabetes quality score than White PwD [Citation77], which further supports the impact of racial disparities in diabetes management. Therefore, it is important that Medicaid reconsider and standardize eligibility criteria for coverage of all insulin delivery technologies and make them available for all patients who would benefit.

However, expanding access and coverage is only part of the solution. Industry needs to focus its efforts on developing more insulin delivery devices that are even less-complex and more affordable to address the specific needs of individuals with T2D and their prescribers. Moreover, because one of the main obstacles to greater adoption of these diabetes technologies is lack of clinician training and education, industry needs to provide educational resources to make it easier for healthcare providers to learn about the advantages and limitations of these technologies, become proficient in their use, understand both the benefits and barriers, and how to effectively convey this information to PwD. Given the ever-increasing prevalence of diabetes and its associated costs, companies that are investing in the development of innovative diabetes technologies need to dedicate financial and human resources for making both healthcare providers and their PwD aware of the benefits of these technologies.

Declaration of financial/other relationships

D Kruger has served on advisory boards and/or speaker bureaus for, and her institution has received research support from Abbott Diabetes Care and Dexcom. D Isaacs has received speaker honoraria from Abbott Diabetes Care, Dexcom, Insulet, Medtronic, and Novo Nordisk. L Hughes has received honoraria from as a member of Abbott Diabetes Care Speaker’s Bureau and Embecta Advisory Board. E Miller has received consulting fees from Abbott, Astra Zeneca, Novo Nordisk Boehringer Ingelheim, Eli Lilly, Merck, Sanofi US, and has acted as a speaker for Abbott, Boehringer Ingelheim, Eli Lilly, and Novo Nordisk. TS Bailey has received research support from Abbott, Capillary Biomedical, Dexcom, Diasome, Eli Lilly, Kowa, Lexicon, Medtronic, Medtrum, Novo Nordisk, REMD, Sanofi, Senseonics, Viacyte, vTv Therapeutics and Zealand Pharma; consulting honoraria from Abbott, Lifescan, Novo Nordisk and Sanofi; and speaking honoraria from Medtronic and Sanofi. The authors have no other relevant affiliations or financial involvement with any organization or entity with a financial interest in or financial conflict with the subject matter or materials discussed in the manuscript apart from those disclosed.

A reviewer on this manuscript has received an honorarium from IPGM for their review work. Peer reviewers on this manuscript have no other relevant financial relationships or otherwise to disclose.

Author contributions

All authors contributed equally in the concept development, writing/revisions, and review of the final manuscript.

Acknowledgments

The authors wish to thank Christopher Parkin for his assistance in preparing this manuscript.

Additional information

Funding

Editorial assistance in writing this manuscript was funded by Embecta Corp. The sponsors had no role in study design, data collection, analysis, decision to publish, or preparation of the manuscript, and the authors received no compensation.

References

  • Davidson JA. The increasing role of primary care physicians in caring for patients with type 2 diabetes mellitus. Mayo Clin Proc. 2010 Dec;85(12 Suppl):S3–S4. doi: 10.4065/mcp.2010.0466
  • Grunberger G, Sze D, Ermakova A, et al. Treatment intensification with insulin pumps and other technologies in patients with type 2 diabetes: results of a physician survey in the United States. Clin Diabetes. 2020;38(1):47–55. doi: 10.2337/cd19-0008
  • International Diabetes Federation. IDF Diabetes Atlas. 10th ed. Brussels: International Diabetes Federation; 2021 [cited 2023 Jan 31 8]. Available from: https://diabetesatlas.org/atlas/tenth-edition/
  • Basu S, Yudkin JS, Kehlenbrink S, et al. Estimation of global insulin use for type 2 diabetes, 2018-30: a microsimulation analysis. Lancet Diabetes Endocrinol. 2019;7(1):25–33.
  • Nathan DM, DCCT/EDIC Research Group. The diabetes control and complications Trial/Epidemiology of diabetes interventions and complications study at 30 years: overview. Diabetes Care. 2014;37:9–16. doi: 10.2337/dc13-2112
  • Holman RR, Paul SK, Bethel A, et al. 10-year follow-up of intensive glucose control in type 2 diabetes. N Engl J Med. 2008;359(15):1577–1589. doi: 10.1056/NEJMoa0806470
  • Fang M, Wang D, Coresh J, et al. Trends in diabetes treatment and control in U.S. Adults, 1999–2018. N Eng J Med 2021; 384(23):2219–2228. doi: 10.1056/NEJMsa203227
  • Khunti S, Khunti K, Seidu S. Therapeutic inertia in type 2 diabetes: prevalence, causes, consequences and methods to overcome inertia. Ther Adv Endocrinol Metab. 2019 May 3;10:2042018819844694. doi: 10.1177/2042018819844694
  • Khunti K, Nikolajsen A, Thorsted BL, et al. Clinical inertia with regard to intensifying therapy in people with type 2 diabetes treated with basal insulin. Diab Obes Metab. 2016;18(4):401–409. doi: 10.1111/dom.12626
  • Brixner D, Ermakova A, Xiong Y, et al. Clinical outcomes of patients with type 2 diabetes treated with multiple daily injection (MDI) of insulin–a retrospective cohort analysis. Clin Ther. 2019;41(2):303–313.
  • Peyrot M, Barnett AH, Meneghini LF, et al. Factors associated with injection omission/non-adherence in the global attitudes of patients and physicians in insulin therapy study. Diab Obes Metab. 2012;14(12):1081. doi: 10.1111/j.1463-1326.2012.01636.x
  • Polonsky WH, Fisher L, Guzman S, et al. Psychological insulin resistance in patients with type 2 diabetes: the scope of the problem. Diabetes Care. 2005;28(10):2543–2545. doi: 10.2337/diacare.28.10.2543
  • Świątoniowska-Lonc N, Tański W, Polański J, et al. Psychosocial determinants of treatment adherence in patients with type 2 diabetes - a review. Diabetes Metab Syndr Obes. 2021 Jun 16;14: 2701–2715. doi: 10.2147/DMSO.S308322
  • Song Y, Song H-J, Han H-R, et al. Unmet needs for social support and effects on diabetes self-care activities in Korean Americans with type 2 diabetes. Diabetes Educ. 2012;38(1):77–85. doi: 10.1177/0145721711432456
  • Biessels GJ, Despa F. Cognitive decline and dementia in diabetes mellitus: mechanisms and clinical implications. Nat Rev Endocrinol. 2018;14(10):591–604. doi: 10.1038/s41574-018-0048-7
  • Orenius T, LicPsych, Säilä H, et al. Fear of injections and needle phobia among children and adolescents: an overview of psychological, behavioral, and contextual factors. SAGE Open Nursing. 2018 Mar 14;4:2377960818759442. doi: 10.1177/2377960818759442
  • Peyrot M, Barnett AH, Meneghini LF, et al. Insulin adherence behaviours and barriers in the multinational global attitudes of patients and physicians in insulin therapy study. Diabet Med. 2012 May;29(5):682–689.
  • ElSayed NA, Aleppo G, Aroda VR, et al. 9. Pharmacologic approaches to glycemic treatment: standards of care in diabetes—2023. Diabetes Care. 2023 Jan;46(Supplement 1):S140–S157. doi: 10.2337/dc23-S009
  • Riddle MC, Aronson R, Home P, et al. Adding once-daily lixisenatide for type 2 diabetes inadequately controlled by established basal insulin: a 24-week, randomized, placebo-controlled comparison (GetGoal-L). Diabetes Care. 2013;36(9):2489–2496. doi: 10.2337/dc12-2454
  • Sikirica MV, Martin AA, Wood R, et al. Reasons for discontinuation of GLP1 receptor agonists: data from a real-world cross-sectional survey of physicians and their patients with type 2 diabetes. Diabetes Metab Syndr Obes. 2017;10:403–412. doi: 10.2147/DMSO.S141235
  • Hemmer A, Maiter D, Buysschaert M, et al. Long-term effects of GLP-1 receptor agonists in type 2 diabetic patients: a retrospective real-life study in 131 patients. Diabetes Metab Syndr. 2019 Jan;13(1):332–336.
  • Chlup R, Runzis S, Castaneda J, et al. Complex assessment of metabolic effectiveness of insulin pump therapy in patients with type 2 diabetes beyond HbA1c reduction. Diabetes Technol Ther. 2018;20(2):153–159. doi: 10.1089/dia.2017.0283
  • Ghazanfar H, Rizvi SW, Khurram A, et al. Impact of insulin pump on quality of life of diabetic patients. Indian J Endocrinol Metab. 2016 Jul;20(4):506–511. doi: 10.4103/2230-8210.183472
  • Honish A, Westerfield W, Ashby A, et al. Health-related quality of life and treatment compliance with diabetes care. Dis Manage. 2006;9(4):195–200. doi: 10.1089/dis.2006.9.195
  • McAdams BH, Rizvi AA. An overview of insulin pumps and glucose sensors for the generalist. J Clin Med. 2016;5(1):5. doi: 10.3390/jcm5010005
  • Tanenbaum ML, Hanes SJ, Miller KM, et al. Diabetes device use in adults with type 1 diabetes: barriers to uptake and potential intervention targets. Diabetes Care. 2017 Feb;40(2):181–187.
  • Freckmann G, Buck S, Waldenmaier D, et al. Insulin pump therapy for patients with type 2 diabetes mellitus: evidence, current barriers, and new technologies. J Diabetes Sci Technol. 2021 Jul;15(4):901–915. doi: 10.1177/1932296820928100
  • Tanenbaum ML, Adams RN, Hanes SJ, et al. Optimal use of diabetes devices: clinician perspectives on barriers and adherence to device use. J Diabetes Sci Technol. 2017;11(3):484–492. doi: 10.1177/1932296816688010
  • Fantasia KL, Wirunsawanya K, Lee C, et al. Racial disparities in diabetes technology use and outcomes in type 1 diabetes in a safety-net hospital. J Diabetes Sci Technol. 2021;15(5):1010–1017. doi: 10.1177/1932296821995810
  • Agarwal S, Schechter C, Gonzalez, et al. Racial–ethnic disparities in diabetes technology use among young adults with type 1 diabetes. Diabetes Technol Ther. 2021 Apr;23(4):306–313. doi: 10.1089/dia.2020.0338
  • Lai CS, Terri H, Lipman TH, et al. Racial and ethnic disparities in rates of continuous glucose monitor initiation and continued use in children with type 1 diabetes. Diabetes Care 2021;44(1):255–257. doi: 10.2337/dc20-1663
  • Willi SM, Miller KM, DiMeglio LA, et al. Racial-ethnic disparities in management and outcomes among children with type 1 diabetes. Pediatrics. 2015;135(3):424–434.
  • Wing RR, Bolin P, Brancati FL, et al. Cardiovascular effects of intensive lifestyle intervention in type 2 diabetes. N Engl J Med 2013;369:145–154.
  • Zhang X, Ji L, Ran X, et al. Gender disparities in lipid goal attainment among type 2 diabetes outpatients with coronary heart disease: results from the CCMR-3B study. Sci Rep. 2017 Oct 4;7(1):12648. doi: 10.1038/s41598-017-13066-z
  • Beck RW, Bergenstal RM, Laffel LM, et al. Advances in technology for management of type 1 diabetes. Lancet. 2019;394(10205):1265–73. doi: 10.1016/S0140-6736(19)31142-0
  • Statista. Number of active physicians in the U.S. in 2022, by specialty area. [cited 2022 Oct 30]. Available from: https://www.statista.com/statistics/209424/us-number-of-active-physicians-by-specialty-area/
  • Oser SM, Oser TK. Diabetes Technologies: We Are All in this Together. Clin Diabetes. 2020 Apr;38(2):188–9. doi: 10.2337/cd19-0046 PMID: 32327892.
  • Vigersky RA, Fish L, Hogan P, et al. The clinical endocrinology workforce: current status and future projections of supply and demand. J Clin Endocrinol Metab. 2014 Sep;99(9):3112–3121.
  • Scott A, O’Cathain A, Goyder E. Socioeconomic disparities in access to intensive insulin regimens for adults with type 1 diabetes: a qualitative study of patient and healthcare professional perspectives. Int J Equity Health. 2019;18:150. doi: 10.1186/s12939-019-1061-8
  • Aleppo G, Parkin CG, Carlson AL, et al. Lost in translation: a disconnect between the science and medicare coverage criteria for continuous subcutaneous insulin infusion. Diabetes Technol Ther. 2021;23(10):715–725. doi: 10.1089/dia.2021.0196
  • Center for Health Care Strategies. Expanding Medicaid Access to Continuous Glucose Monitors. 2022 Jan. Available from: https://www.chcs.org/media/Expanding-Medicaid-Access-to-Continuous-Glucose-Monitors_011222.pdf
  • Gajewska KA, Biesma R, Bennett K, et al. Barriers and facilitators to accessing insulin pump therapy by adults with type 1 diabetes mellitus: a qualitative study. Acta Diabetol. 2021;58(1):93–105. doi: 10.1007/s00592-020-01595-5
  • O’Donovan A, Oser SM, Parascando J, et al. Determining the perception and willingness of primary care providers to prescribe advanced diabetes technologies. J Patient Cent Res Rev. 2021;8(3):272–276.
  • Bergloff A, Stratton E, Briggs Early K. A cross-sectional pilot survey of rural clinic attitudes and proficiency with insulin pumps and continuous glucose monitoring devices. Diabetes Technol Ther. 2019 Nov;21(11):665–670. doi: 10.1089/dia.2019.0161
  • Ginsberg BH. Patch pumps for insulin. J Diabetes Sci Technol. 2019;13(1):27–33. doi: 10.1177/1932296818786513
  • Ekanayake P, Edelman S. Identifying those patients with type 2 diabetes who might benefit from insulin pump therapy: literature review, clinical opportunities, potential benefits & challenges. Diab Obes Metab. 2023 Mar 22;25(S2):3–20. doi: 10.1111/dom.15059
  • Parkner T, Møller MK, Chen JW, et al. Overnight CSII as supplement to oral antidiabetic drugs in type 2 diabetes. Diab Obes Metab. 2008;10(7):556–563. doi: 10.1111/j.1463-1326.2007.00748.x
  • Taylor M, Sahota T. New technologies in insulin delivery. Pract Diabetes. 2013;30(1):21–26. doi: 10.1002/pdi.1736
  • Asian Hospital & Healthcare Management. Novel Sigi™ insulin management system developed for diabetes mellitus treatment. [cited 2023 Dec 26]. Available from: https://www.asianhhm.com/technotrends/novel-sigi-insulin-management-system-developed-for-diabetes-mellitus-treatment
  • Davies MJ, Gagliardino JJ, Gray LJ, et al. Real-world factors affecting adherence to insulin therapy in patients with type 1 or type 2 diabetes mellitus: a systematic review. Diabet Med. 2013;30(5):512–24. doi: 10.1111/dme.12128
  • Heinemann L, Waldenmaier D, Kulzer B, et al. Patch pumps: are they all the same? J Diabetes Sci Technol. 2019;13(1):34–40. doi: 10.1177/1932296818795150
  • Reznik Y, Cohen O Insulin pump for type 2 diabetes: use and misuse of continuous subcutaneous insulin infusion in type 2 diabetes. Diabetes Care. 2013;36(suppl 2):s219–s225. doi: 10.2337/dcS13-2027
  • Ziegler R, Waldenmaier D, Kamecke U, et al. Accuracy assessment of bolus and basal rate delivery of different insulin pump systems used in insulin pump therapy of children and adolescents. Pediatr Diabetes. 2020;21(4):649–656.
  • Laubner K, Singler E, Straetener J, et al. Comparative dose accuracy of durable and patch insulin pumps under laboratory conditions. Diabetes Technol Ther. 2019;21(7):371–378. doi: 10.1089/dia.2019.0089
  • Heinemann L, Krisiunas L. Diabetes technology and waste: a complex problem piling up!. J Diabetes Sci Technol. 2019;13(5):815–816. doi: 10.1177/1932296819836395
  • Herman A, de Montjoye L, Tromme I, et al. Allergic contact dermatitis caused by medical devices for diabetes patients: a review. Contact Dermatitis. 2018;79(6):331–335. doi: 10.1111/cod.13120
  • Lajara R, Fetchick DA, Morris TL, et al. Use of V-Go® insulin delivery device in patients with sub-optimally controlled diabetes mellitus: a retrospective analysis from a large specialized diabetes system. Diabetes Ther. 2015;6:531–545. 4 10.1007/s13300-015-0138-7
  • Lajara R, Davidson JA, Nikkel CC, et al. Clinical and cost-effectiveness of insulin deliver with V-Go® disposable insulin deliver device versus multiple daily injections in patients with type 2 diabetes inadequately controlled on basal insulin. Endocr Pract. 2016;22(6):726–735. doi: 10.4158/EP151182.OR
  • Lajara R, Nikkel C, Abbott S. The clinical and economic impact of the V-Go® disposable insulin delivery device for insulin delivery in patients with poorly controlled diabetes at high risk. Drugs Real World Outcomes. 2016 Jun;3(2):191–199. doi: 10.1007/s40801-016-0075-4
  • Sutton D, Charissa D, Higdon CD, et al. Clinical benefits over time associated with use of V-Go wearable insulin delivery device in adult patients with diabetes: a retrospective analysis. Adv Ther. 2018;35(5):631–643. doi: 10.1007/s12325-018-0703-3
  • Grunberger G, Rosenfeld CR, Bode BW, et al. Effectiveness of V-Go® for patients with type 2 diabetes in a real-world setting: a prospective observational study. Drugs Real World Outcomes. 2020 Mar;7(1):31–40.
  • Bohannon N, Bergenstal R, Cuddihy R, et al. Comparison of a novel insulin bolus-patch with pen/syringe injection to deliver mealtime insulin for efficacy, preference, and quality of life in adults with diabetes: a randomized, crossover, multicenter study. Diabetes Technol Ther. 2011;13(10):1031–1037. doi: 10.1089/dia.2011.0047
  • Mader JK, Lilly LC, Aberer F, et al. A feasibility study of a 3-day basal-bolus insulin delivery device in individuals with type 2 diabetes. Diabetes Care. 2014 May;37(5):1476–9. doi: 10.2337/dc13-2238
  • Mader JK, Lilly LC, Aberer F, et al. Improved glycaemic control and treatment satisfaction with a simple wearable 3-day insulin delivery device among people with type 2 diabetes. Diabet Med. 2018 Oct;35(10):1448–1456.
  • Layne JE, Parkin CG, Zisser H. Efficacy of a tubeless patch pump in patients with type 2 diabetes previously treated with multiple daily injections. J Diabetes Sci Technol. 2017;11(1):178–179. doi: 10.1177/1932296816653143
  • Sutton D, Higdon C, Carmon M, et al. Regular insulin administered with the V-Go disposable insulin delivery device in a clinical diabetes setting: a retrospective analysis of efficacy and cost. Clin Diabetes. 2016 Oct;34(4):201–205. doi: 10.2337/cd16-0021
  • Hermans N, Lilly LC, Mader JK, et al. Novel simple insulin delivery device reduces barriers to insulin therapy in type 2 diabetes. J Diabetes Sci Technol. 2015 May;9(3):581–587.
  • Isaacs D, Kruger DF, Shoger D, et al. Patient perceptions of satisfaction and quality of life regarding use of a novel insulin delivery device. Clin Diabetes. 2022;41(2):198–207. doi: 10.2337/cd22-0034
  • Wahlqvist P, Warner J, Morlock R. A cost-effectiveness of simple insulin infusion devices compared to multiple daily injections in uncontrolled type 2 diabetics in the united states based on a simulation model. JHEOR. 2018;6(1):84–95. doi: 10.36469/9789
  • Cziraky MJ, Abbott S, Nguyen M, et al. A pragmatic clinical trial to compare the real-world effectiveness of V-Go versus standard delivery of insulin in patients with advanced type 2 diabetes. JHEOR. 2019;6(2):70–83. doi: 10.36469/9731
  • Carlson AL, Huyett LM, Jantz J, et al. Improved glycemic control in 3,592 adults with type 2 diabetes mellitus initiating a tubeless insulin management system. Diabet Res Clin Pract. 2021 Mar 9;174 [cited 2021 Apr 26]. 108735. Available from: https://pubmed.ncbi.nlm.nih.gov/33711396/
  • Thompson B, Cook CB. Insulin pumping patches: emerging insulin delivery systems. J Diabetes Sci Technol. 2019;13(1):8–10. doi: 10.1177/1932296818814541
  • Sutton D, Higdon C, Carmon M, et al. Regular insulin administered with the V-Go disposable insulin delivery device in a clinical diabetes setting: a retrospective analysis of efficacy and cost. Clin Diabetes. 2016;34(4):201–205. doi: 10.2337/cd16-0021
  • Peyrot M, Rubin RR, Kruger DF, et al. Correlates of insulin injection omission. Diabetes Care. 2010;33(2):240–245. doi: 10.2337/dc09-1348
  • Pauley ME, Berget C, Messer LH, et al. Barriers to uptake of insulin technologies and novel solutions. Med Devices (Auckl). 2021;14:339–354. doi: 10.2147/MDER.S312858
  • Hill-Briggs F, Adler NE, Berkowitz SA, et al. Social determinants of health and diabetes: a scientific review. Diabetes Care. 2021;44(1):258–279. doi: 10.2337/dci20-0053
  • Kazemian P, Shebl FM, McCann N, et al. Evaluation of the cascade of diabetes care in the United States, 2005-2016. JAMA Intern Med. 2019;179:1376–1385. doi: 10.1001/jamainternmed.2019.2396