Technical and diagnostic performance of a new fully automated immunoassay for the determination of intact fibroblast growth factor 23 (FGF23)

ORCID Icon & ORCID Icon
Pages 584-590 | Received 20 Apr 2018, Accepted 17 Sep 2018, Published online: 31 Oct 2018
 

Abstract

There is growing interest in measuring plasma fibroblast growth factor 23 (FGF23) concentrations in a number of clinical settings. However, a reliable assay with acceptable performance is lacking. Plasma samples of healthy adults and patients with different stages of chronic kidney disease (CKD) were used to compare the precision, recovery, linearity and the pre-analytical stability characteristics of a new fully automated FGF23 (intact) assay with a commercially available FGF23 (intact) ELISA. Method agreement was evaluated, reference and stage-specific ranges for kidney disease were established. Other biomarkers relevant for CKD were measured and compared with the FGF23 assays. The fully automated FGF23 (intact) assay demonstrated superior performance compared with the ELISA. A marked positive proportional bias was detected relative to the ELISA assay readout, especially in samples of higher concentration of patients undergoing hemodialysis. Overall, the method comparison revealed a poor degree of correlation. A significant inverse correlation was found between the glomerular filtration rate and both FGF23 assays (both p < .001). Regression analysis revealed that both assays are suitable to predict progression of CKD. A positive correlation was found between FGF23 and phosphate, parathyroid hormone (PTH) and vitamin D, 25(OH)D and 1,25(OH)2D-total assays, respectively. Cutoff points between different stages of CKD were calculated by receiver operator characteristic analysis. The fully automated assay displayed an improved discrimination compared with the ELISA, especially in mild to moderate kidney disease. The new fully automated FGF23 (intact) assay demonstrates excellent analytical performance data and represents a robust, fast and precise alternative to manual FGF23 testing.

Disclosure statement

No potential conflict of interest was reported by the authors.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 200.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.