Evaluation of the Diesse Cube 30 touch erythrocyte sedimentation method in comparison with Alifax test 1 and the manual Westergren gold standard method

ORCID Icon, , , , , , , & show all
Pages 181-186 | Received 25 Jun 2020, Accepted 24 Jan 2021, Published online: 14 Feb 2021
 

Abstract

The erythrocyte sedimentation rate (ESR) is a traditional nonspecific laboratory test used for the assessment of inflammation. Even if its usefulness is nowadays being largely debated, it is still considered a valuable laboratory test in selected clinical conditions, such as rheumatoid diseases, orthopedic infections and Hodgkin’s lymphoma, and it can be used for the infectious, inflammatory, malignancies, and autoimmune diseases follow-up. The introduction of new methodologies on semi-automated and automated analyzers started about four decades ago and opened a new era of ESR analysis characterized by shorter assay time, use of (EDTA) undiluted blood, that increases sample stability and allows using a single sample for also other hematologic tests, and greater safety for laboratory personnel. In this context, the aim of this study was to evaluate the performances of new device Diesse Cube 30 touch, comparing it with Alifax Test 1 and with the gold standard Westergren method. The new Diesse Cube 30 touch for determination of the ESR shows a good correlation with the manual Westergren gold standard method in a shorter time, and in a standardized way, since all the phases of the test are automatized. The Diesse Cube 30 touch respect the manual gold standard method, displayed a small bias to confirm that the new automated test system tended to have a small bias for ESR values (mean positive bias +0.2 mm/h). The findings of the present study show that the Diesse Cube 30 touch Westergren-based method can be a valid alternative in laboratory analysis for the determination of ESR.

Acknowledgments

We acknowledge DIESSE for instrument and technical support.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 200.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.