Evaluation of a new point-of-care testing for creatinine and urea measurement

, , , , , , , , , & show all
Pages 290-297 | Received 19 Nov 2020, Accepted 21 Feb 2021, Published online: 28 Apr 2021
 

Abstract

Point of care testing makes it possible to obtain results in an extremely short time. Recently, radiometer has expanded the panel of tests available on its ABL90 FLEX PLUS blood gas analyzer (ABL90) by adding urea and creatinine. The aim of this study was to verify the performance of these new parameters. This included assessment of imprecision, linearity, accuracy by comparison with central laboratory standard assays and interferences. In addition, clinical utility in a dialysis center was evaluated. Within-lab coefficients of variation were close to 2%. The mean and limits of agreement (mean ± 1.96 SD) of the difference between ABL90 and Roche enzymatic assays on cobas 8000 were 0.5 (from −1.4 to 2.3) mmol/L and −0.9 (from −19.5 to 17.8) µmol/L for urea and creatinine, respectively. The ABL90 enzymatic urea and creatinine assays met the acceptance criteria based on biological variation for imprecision and showed good agreement with central laboratory. The two assays were unaffected by hematocrit variation between 20 and 70%, hemolysis and icterus interferences. It should be noted that the relationship between lab methods and ABL90 was conserved even for high pre-dialysis values allowing easy access to dialysis adequacy parameters (Kt/V) and muscle mass evaluation (creatinine index). Rapid measurement of creatinine and urea using whole blood specimens on ABL90 appears as a fast and convenient method. Analytical performances were in accordance with our expectations without any significant interferences by hemolysis or icterus.

Acknowledgements

The authors acknowledge radiometer for providing quality control materials and reagents for this study. Radiometer has no role in directing the study or influencing the interpretation of the study results.

Disclosure statement

The authors have no conflict of interest to disclose.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 200.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.