215
Views
3
CrossRef citations to date
0
Altmetric
Scientific Articles

A comparison of the effects of carbon dioxide and medical air for abdominal insufflation on respiratory parameters in xylazine-sedated sheep undergoing laparoscopic artificial insemination

, &
Pages 167-171 | Received 02 Sep 2017, Accepted 06 Mar 2018, Published online: 25 Apr 2018
 

Abstract

AIMS: To determine if abdominal insufflation with medical air will improve oxygenation and ventilation parameters when compared to insufflation with CO2 in xylazine-sedated sheep undergoing laparoscopic artificial insemination (AI).

METHODS: Forty-seven sheep underwent oestrus synchronisation and were fasted for 24 hours prior to laparoscopic AI. Each animal was randomised to receive either CO2 or medical air for abdominal insufflation. An auricular arterial catheter was placed and utilised for serial blood sampling. Respiratory rates (RR) and arterial blood samples were collected at baseline, after xylazine (0.1 mg/kg I/V) sedation, 2 minutes after Trendelenburg positioning, 5 minutes after abdominal insufflation, and 10 minutes after being returned to a standing position. Blood samples were collected in heparinised syringes, stored on ice, and analysed for arterial pH, partial pressure of arterial O2 (PaO2), and CO2 (PaCO2). The number of ewes conceiving to AI was also determined.

RESULTS: Repeated measures ANOVA demonstrated temporal effects on RR, PaO2, PaCO2 and arterial pH during the laparoscopic AI procedure (p<0.001), but no difference between insufflation groups (p>0.01). No sheep experienced hypercapnia (PaCO2>50 mmHg) or acidaemia (pH<7.35). Hypoxaemia (PaO2<70 mmHg) was diagnosed during the procedure in 14/22 (64%) ewes in the CO2 group compared with 8/23 (35%) ewes in the medical air group (p=0.053). Overall, 15/20 (75%) ewes in the CO2 group conceived to AI compared with 16/22 (72.7%) in the medical air group (p=0.867).

CONCLUSIONS AND CLINICAL RELEVANCE: There were no statistical or clinical differences in RR, PaO2, PaCO2, pH, or conception to AI when comparing the effects of CO2 and medical air as abdominal insufflation gases. None of the sheep experienced hypercapnia or acidaemic, yet 42% (19/45) of sheep developed clinical hypoxaemia, with a higher percentage of ewes in the CO2 group developing hypoxaemia than in the medical air group. Based on the overall analysis, medical air could be utilised as a comparable alternative for abdominal insufflation during laparoscopic AI procedures.

Acknowledgements

We would like to thank the clients for allowing data collection during these regularly scheduled clinical procedures. We would also like to thank the students and support staff for their time and assistance as well as Rebecca Burzette for her huge involvement in the statistical analysis.

Additional information

Funding

This study was funded through the Iowa State University Veterinary Clinical Science Research Incentive Grant.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 213.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.