Comparison of the effect of oxygen supplementation using flow-by or a face mask on the partial pressure of arterial oxygen in sedated dogs

, , , &
Pages 36-39 | Received 14 May 2018, Accepted 13 Sep 2018, Published online: 10 Oct 2018
 

Abstract

AIMS

To compare the effect of oxygen supplementation using flow-by or a face mask on the partial pressure of arterial oxygen (PaO2) in sedated dogs.

METHODS

Twenty healthy dogs weighing >15 kg, of mixed sex and breed, were enrolled in a randomised cross-over study. Each dog was sedated with I/M 0.015 mg/kg medetomidine and 0.5 mg/kg methadone. Twenty minutes later dogs were exposed to two 5-minute treatment periods of oxygen supplementation separated by a 15-minute washout period during which dogs were allowed to breathe room air. During the treatment periods, oxygen was delivered at a flow rate of 3 L/minute either through a face mask (face mask oxygenation), or via a tube held 2 cm from the dog’s nares (flow-by oxygenation). The order in which the treatments were administered was randomised. Arterial blood was collected for blood gas analysis and rectal temperature measured at four times: prior to commencing treatments, after each treatment, and at the end of the 15 minutes washout period between treatments.

RESULTS

The mean PaO2 in arterial samples taken from the dogs after face mask oxygen supplementation was 371.3 (SE 13.74) mmHg which was higher than in samples taken after they received flow-by oxygen supplementation (182.2 (SE 6.741) mmHg; p<0.001). The mean PaO2 in samples taken after receiving either form of oxygen supplementation was higher than in samples taken after the dogs had been breathing room air (82.43 (SE 2.143) mmHg; p<0.001). There was no association between sex, age, weight or breed of dogs and blood gas parameters or rectal temperature (p>0.05).

CONCLUSIONS

Oxygen supplementation delivered using a face mask was more effective at increasing PaO2 than flow-by oxygen supplementation. Flow-by oxygen supplementation at a distance of 2 cm from the nose may be a suitable alternative when the use of a face mask is not tolerated by the patient.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 213.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.