213
Views
5
CrossRef citations to date
0
Altmetric
Original Article

The impact of nuchal cord on umbilical cord blood gas analysis and ischaemia-modified albumin levels in elective C-section

, , , , &
Pages 1099-1103 | Published online: 18 Jun 2018
 

Abstract

This study was designed to evaluate umbilical cord ischaemia-modified albumin (IMA) levels and the cord blood gas parameters of foetuses with or without nuchal cords, at the time of elective C-section. The cross-sectional study population consisted of the patients who were admitted to the Tertiary Care Center between February and June 2015. Women with uncomplicated single term gestations between 37 and 40 completed weeks and scheduled for elective C-sections were included in the study. Fifty cases with a nuchal cord and 50 cases without a nuchal cord were recruited. Nuchal cord blood gas analysis and the IMA levels were evaluated. The IMA levels in umbilical artery of foetuses both in the study and control groups were similar (0.714 ± 0.150 vs. 0.689 ± 0.107 ABSU, p = .340, respectively). The umbilical artery pH values of the study group were significantly lower than that in the control group (7.31 ± 0.04 vs. 7.32 ± 0.03, p = .042; respectively). The results of the current study indicate that the nuchal cord has an impact on the foetal cord blood gas parameters to some extent before the initiation of labour. Fortunately, this impact does not end up with foetal tissue ischaemia, as confirmed by the IMA levels.

    Impact statement

  • What is already known on this subject? The impact of nuchal cord on perinatal outcomes has been the subject of research for many years. Although the accumulated data has pointed out some unfavourable perinatal effects, the heterogeneity of the study groups both including a vaginal delivery and C-section and the inability to adjust the interfering factors ended up with some controversies. This is why there is not much known about the effects of the nuchal cord in women who are not in the labour process.

  • What do the results of this study add? The current study aimed to exclude the interfering effects such as the active stage of labour. In this study, elective caesarean sections were selected as the study population to evaluate the effects of the nuchal cord on cord blood gas parameters and the IMA values. pH analysis in cord blood is used to detect hypoxia and the IMA is a new ischaemia marker. The results revealed that the in utero nuchal cord is associated with a significantly higher pCO2 and lower pH values and similar IMA values.

  • What are the implications of these findings for clinical practice and/or further research? The final outcome supports that the nuchal cord causes alterations in cord blood gas analysis but this does not reach critical levels. Therefore, the results show that there is no need to change clinical practice when the nuchal cord is detected by ultrasound in a term gestation.

Disclosure statement

The authors report no conflicts of interest.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.