A comparative in vitro study of standard facemask jet nebulization and high-flow nebulization in bronchiolitis

ORCID Icon, , , , &
Pages 13-21 | Received 25 Oct 2018, Accepted 20 Mar 2019, Published online: 22 Apr 2019
 

Abstract

Aim of Study: The use of a nebulizer paired with high-flow nasal cannulas (HFNC) has been proposed for drug delivery in bronchiolitis. Particle size nebulized is a relevant factor determining the efficacy of the nebulization. We replicated in vitro the theoretical parameters most widely used in bronchiolitis and we compared the size of the droplet nebulized with a standard nebulizer and a nebulizer integrated into HFNC. Materials and Methods: We used laser diffraction to analyze the particle size nebulized (volume median diameter Dv50). The standard system was a jet nebulizer connected to a facemask with a flow rate of 8 L/min (JN). Three designs were used as nebulizers integrated into HFNC: a vibrating mesh nebulizer set 1) before (HFNC-BH) and 2) after (HFNC-AH) the humidifier, and 3) a jet nebulizer connected before the nasal cannula (HFNC-BNC). HFNC was used with neonatal (3–8 L/min) and infant cannulas (8–15 L/min). Results: Droplet size was similar among the three drugs studied. A lower particle size was obtained when using the nebulization system integrated into HFNC compared to the standard nebulizer, regardless of the flow rate and the nasal cannula used when the position of the nebulizer was before the nasal cannula (p < 0.05): 6.89 µm (JN), 2.49 µm (HFNC-BNC 3 L/min), 2.59 µm (HFNC-BNC 5 L/min), 2.44 µm (HFNC-BNC 8 L/min), 3.22 µm (HFNC-BNC 10 L/min), 3.23 µm (HFNC-BNC 13 L/min), 3.16 µm (HFNC-BNC 15 L/min). The particle size was lower in HFNC-BF compared to the HFNC-AH using neonatal nasal cannula (3–8 L/min) (p < 0.05). Conclusion: The use of a nebulizer integrated with HFNC has shown promising results in an experimental scenario of bronchiolitis. The particle size achieved with the nebulizer placed before the humidifier is equivalent to the one obtained via conventional nebulization, and it is even smaller when the integrated nebulizer is placed before the nasal cannulas.

Acknowledgments

Aerogen, Fisher, Paykel Healthcare, and IESMAT kindly provided the nebulizer, the high-flow nasal cannulas therapy equipment, and the Malvern Spraytec required for experiments, respectively, free of charge. These companies were not involved in the study design, data interpretation, or manuscript drafting.

Declaration of interest

The authors declare that they have no competing interests.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.