Using VR to Investigate the Relationship between Visual Acuity and Severity of Simulated Oscillopsia

, , , , &
Pages 1611-1618 | Received 26 Feb 2020, Accepted 11 May 2020, Published online: 17 Jun 2020
 

ABSTRACT

Purpose

Oscillopsia is a debilitating symptom resulting from involuntary eye movement most commonly associated with acquired nystagmus. Investigating and documenting the effects of oscillopsia severity on visual acuity (VA) is challenging. This paper aims to further understanding of the effects of oscillopsia using a virtual reality simulation.

Methods

Fifteen right-beat horizontal nystagmus waveforms, with different amplitude (1°, 3°, 5°, 8° and 11°) and frequency (1.25 Hz, 2.5 Hz and 5 Hz) combinations, were produced and imported into virtual reality to simulate different severities of oscillopsia. Fifty participants without ocular pathology were recruited to read logMAR charts in virtual reality under stationary conditions (no oscillopsia) and subsequently while experiencing simulated oscillopsia. The change in VA (logMAR) was calculated for each oscillopsia simulation (logMAR VA with oscillopsia – logMAR VA with no oscillopsia), removing the influence of different baseline VAs between participants. A one-tailed paired t-test was used to assess statistical significance in the worsening in VA caused by the oscillopsia simulations.

Results

VA worsened with each incremental increase in simulated oscillopsia intensity (frequency x amplitude), either by increasing frequency or amplitude, with the exception of statistically insignificant changes at lower intensity simulations. Theoretical understanding predicted a linear relationship between increasing oscillopsia intensity and worsening VA. This was supported by observations at lower intensity simulations but not at higher intensities, with incremental changes in VA gradually levelling off. A potential reason for the difference at higher intensities is the influence of frame rate when using digital simulations in virtual reality.

Conclusions

The frequency and amplitude were found to equally affect VA, as predicted. These results not only consolidate the assumption that VA degrades with oscillopsia but also provide quantitative information that relates these changes to amplitude and frequency of oscillopsia.

Disclosure statement

The authors report no conflicts of interest and have no proprietary interest in any of the materials mentioned in this article.

Additional information

Funding

This work was supported by Sheffield Hospitals Charitythrough Insigneo – The Institute for In-silico Medicine; Bardhan Research and Education Trust of Rotherham.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 555.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.