223
Views
3
CrossRef citations to date
0
Altmetric
Glaucoma

Repeatability and Reproducibility of Anterior Chamber Angle Measurement with Swept-Source Optical Coherence Tomography in Patients with Primary Angle Closure Suspect

ORCID Icon, , , , , , , , , , , & show all
Pages 1853-1860 | Received 01 Nov 2020, Accepted 01 Jun 2021, Published online: 12 Jul 2021
 

ABSTRACT

Purpose: To evaluate the inter- and intra-observer reliability of anterior chamber (AC) angle measurements obtained by swept-source optical coherence tomography (SS-OCT).

Methods: Forty-eight consecutive patients diagnosed with primary angle closure suspect (PACS) were included. Three masked observers at different training levels (one glaucoma specialist, one ophthalmology resident, and one pre-medical college student) measured 192 SS-OCT images of the PACS patients. One observer (the glaucoma specialist) repeated measurements 1 week later. SS-OCT parameters included: Anterior segment volume, including corneal, AC, and iris volume; anterior segment dimensions, including AC depth and width (ACD, ACW), and lens vault (LV); and angle parameters, including angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and the trabecular iris angle (TIA). Intraclass correlation coefficients (ICCs) were used to measure reliability.

Results: For inter-observer reproducibility, ICCs of corneal, AC, and iris volumes were 0.952 to 0.998. ICCs of ACD at all axes were above 0.989. ICCs of ACW and LV were smallest in the 90°-270° axis (0.751 and 0.768) but not significantly different from other axes. ARA, TISA, and TIA at all angles had significantly smallest ICCs 250 µm from the scleral spur compared with 500 µm and 750 µm. The ICCs comparing observers with different training levels had similar ranges and followed similar trends. For intra-observer repeatability, the smallest ICC was 0.843. Decreasing AC depth correlated with increased inter-observer reproducibility.

Conclusions: We found excellent intra-observer repeatability for all SS-OCT parameters. Angle measurements have more variation among the observers when taken 250 µm from the scleral spur. Shallow AC might lead to more variability for angle parameters. Non-expert observers may be recruited for high-quality image grading with standard training.

Declaration of interest statement

No conflicting relationship exists for any author.

Supplementary material

Supplemental data for this article can be accessed on the publisher’s website.

Additional information

Funding

This work was supported by funding from the National Eye Institute (NEI EY028747-01) to Dr Ying Han; This work was made possible, in part, by NEI P30 EY002162 - Core Grant for Vision Research, and by an unrestricted grant from Research to Prevent Blindness, New York, NY.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 555.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.