How effective are face coverings in reducing transmission of COVID-19?

ORCID Icon, , , , , , & show all
Pages 473-487 | Received 30 Apr 2021, Accepted 11 Jan 2022, Published online: 07 Apr 2022

Abstract

In the COVID–19 pandemic, billions are wearing face masks, in both health care settings and in public. Which type of mask we should wear in what situation, is therefore important. There are three basic types: cotton, surgical, and respirators (e.g., FFP2, N95 and similar). All are essentially air filters worn on the face. Air filtration is relatively well understood, however, we have almost no direct evidence on the relative role played by aerosol particles of differing sizes in disease transmission. But if the virus concentration is assumed independent of aerosol particle size, then most virus will be in particles 1 µm. We develop a model that predicts surgical masks are effective at reducing the risk of airborne transmission because the filtering material most surgical masks use is highly effective at filtering particles with diameters 1 µm. However, surgical masks are significantly less effective than masks of FFP2, N95 and similar standards, mostly due to the poor fit of surgical masks. Earlier work found that 30% of the air bypasses a surgical mask and is not filtered. This highlights the fact that standards for surgical masks do not specify how well the mask should fit, and so are not adequate for protection against COVID-19.

Copyright © 2022 American Association for Aerosol Research

1. Introduction

The COVID-19 pandemic has brought critically neglected areas of infection control onto the global stage (Dancer Citation2020). Most notably this includes the risk of airborne transmission and the strategies required to mitigate it (Morawska and Cao Citation2020). The airborne route involves transmission of viral material through aerosols, and is the dominant transmission route for SARS-CoV-2 (Prather et al. Citation2020a). Respiratory aerosol particles vary in diameter from 0.1 to 100 µm (Bar-On et al. Citation2020; Prather et al. Citation2020b). Given this broad size range, we can expect their potency as disease vectors and the effectiveness of interventions to be size-dependent.

Face coverings are mandated (or strongly encouraged) around the world in healthcare settings and public spaces (Masks4All Citation2020; YouGov Citation2020). The current evidence suggests that they reduce airborne transmission of SARS-CoV-2 (Greenhalgh et al. Citation2020; DELVE Initiative Citation2020; Howard et al. Citation2021). An important question concerns what kind of mask should be worn in each situation? Different levels of protection are required in healthcare settings than out in the wider community, and requirements will further depend on the particular circumstances. For example, Jones et al. (Citation2021a) found that healthcare workers in critical care had lower than average infection rates, suggesting that other healthcare workers may be underprotected. There are essentially three types of face coverings: (i) fabric or cloth coverings, (ii) surgical masks, and (iii) respirators (e.g., N95/KN95/FFP2 or similar). Here we use ‘mask’ and ‘face covering’ interchangeably to refer to any of these. There are also masks designed to be resistant to oil aerosols, and to be splash resistant. We do not consider these here.

Here, we explore the aerosol size-dependent factors affecting mask effectiveness in aerosol particles 10 µm in diameter.

1.1. Aerosol dynamics and transmission

Much work has focused on how far aerosols are transmitted, with a particular focus on establishing guidelines for physical distancing. Multiple studies have examined the transport of respired aerosols in still air (Xie et al. Citation2007; Bourouiba et al. Citation2014; Liu et al. Citation2017; Bazant and Bush Citation2020), and other studies have explored the effect that masks have on exhalation plumes (Tang et al. Citation2009; Dbouk and Drikakis Citation2020; Viola et al. Citation2021; Li et al. Citation2021). Aerosol particle size is a crucial factor affecting their distance traveled, but the focus in such studies is typically on the striking dynamical change that occurs for coarse aerosol particles with diameters in the range ∼10 to 100 µm. With these large particles, fragmentation as they pass through masks is a particular concern (Bourouiba et al. Citation2014; Scharfman et al. Citation2016; Mittal et al. Citation2020; Poon et al. Citation2020; Fischer et al. Citation2020; Sharma et al. Citation2021).

However, finer aerosol particles may be disease vectors. Fine respiratory particles arise from within the lower respiratory tract (Johnson et al. Citation2011), where SARS-CoV-2 pathogenesis is known to occur (Jin et al. Citation2020; Kanimozhi et al. Citation2021). Viral RNA has been found in aerosol particles smaller than ∼10 µm, though finding viable virus titers seems to depend on particle size (Santarpia et al. Citation2021). One hamster study found that the majority of virus was contained in aerosol particles smaller than 5 µm (Hawks et al. Citation2021). These fine particles have such long persistence times (Vuorinen et al., 2020) that how far they travel in plumes is less important than factors such as masking and air ventilation in indoor environments, where filtration is size-dependent.

A widespread model for airborne transmission in indoor environments is the Wells-Riley equation (Riley et al. Citation1978; Gammaitoni and Nucci Citation1997), which has been adapted to assess the risk of infection with SARS-CoV-2 (Jimenez et al. Citation2020; Buonanno et al. Citation2020; Dai and Zhao Citation2020). This model considers the limit where air in a room is well-mixed, i.e., ignoring any currents or expiratory jets, while still considering such factors as air ventilation, particle deposition rates, and the rate of release of so-called infection quanta into the room. An infection quantum is a theoretical airborne dose expected to infect  63% of susceptible people. Transmission risk in these models is highly dependent on the rate q at which an infected person releases these quanta. Given the multitude of factors involved in airborne transmission, biological and otherwise, there is large uncertainty in q for the new SARS-CoV-2 pathogen (Buonanno et al. Citation2020; Dai and Zhao Citation2020). One novel study examined the effect that distance, ventilation and masks have on infection risk by performing CFD simulations on a realistic 3d representation of a classroom (Foster and Kinzel Citation2021), finding reasonable overall agreement with Wells-Riley modeling despite significant deviations.

Particle size-dependence is incorporated into the Wells-Riley models (and its derivatives) through the particle deposition rates and the q factor, whereas mask effectiveness has been incorporated solely as a dilution parameter as in, e.g., Dai and Zhao (Citation2020). Masks are in effect assumed to act solely by modifying the other parameters, creating an effective ventilation rate and an effective q (Dai and Zhao Citation2020). The complex interplay between mask effectiveness and biological factors such as aerosol production and viral load, and how this varies with particle size, has not yet been incorporated into these models.

1.2. Mask standards

A mask is nothing more or less than an air filter worn on the face. Various governments have introduced minimum standards for masks. Here, we will briefly outline two European and two American standards.

For each type of face covering there are different standards. Most fabric coverings are not made to a standard. However, ASTM International recently introduced a ‘barrier face covering standard’ F3502 (ASTM International Citation2021a). This specifies filtration in terms of a polydisperse aerosol of sodium chloride crystals with sizes around 100 nm, but does not specify how well the mask must fit the face to avoid air leaking around the edges of the mask.

For surgical masks, standards typically only cover the filtration of the material the masks is made from. While for respirators, the standards cover both the filtration efficiency of the material and how well it actually performs while worn: the standards therefore specify the quality of the mask fit (European Committee for Standardization Citation2019a; U.S. Public Health Service Citation1995). As an example, we can look at the European standard EN 149—‘Filtering Halfmasks to protect against particles’, for a filtering facepiece respirator (FFP) standard. This has three levels with increasingly stringent requirements: FFP1, 2 and 3. The FFP2 standard requires (simply speaking) (European Committee for Standardization Citation2019a):

  1. The filtering material must filter out at least 94% by mass of a test aerosol.

  2. The average filtration of test subjects wearing the mask (while performing standard tasks) must be at least 92% of the mass of the test aerosol.

The test aerosol for European standards of filtering facepiece respirator (FFP), is specified by the European standard EN 13274-7 (European Committee for Standardization Citation2019a). A convenient aerosol of sodium chloride crystals is used where ‘the number median of the particle size distribution is between a diameter of 60 and 100 nm, with a geometric standard deviation between 2.0 and 3.0′ (European Committee for Standardization Citation2019a; Zoller et al. Citation2021). The fraction filtered is assessed by measuring the mass of sodium, i.e., the mass (rather than number) fraction filtered is assessed.

Note that the USA N95 standard uses light scattering from aerosol particles to measure filtration. The aerosol specification, is also slightly different (U.S. Public Health Service Citation1995). Thus, although the USA and European methods are similar, the filtration numbers are not exactly comparable.

The European standard for surgical masks is EN 14683—‘Medical face masks—Requirements and test methods’ (European Committee for Standardization Citation2019b). The only filtration requirement is that the material of the mask should filter an aerosol of particles containing the bacterium Staphylococcus aureus. The bacterial filtration efficiency (BFE) of the mask material is the fractional reduction in the number of colony forming units (CFUs) when the aerosol is passed through the material. For a Type II mask under this standard, the BFE must achieve a CFU reduction of at least 98%. The aerosol is required to have a mean diameter of 3±0.3 µm (European Committee for Standardization Citation2019b), and specifies a cascade impactor be used to measure droplet size. Note that the standard does not specify what the distribution of droplet sizes is, but it does specify that the droplets are formed immediately before the mask, allowing little time for evaporation (European Committee for Standardization Citation2019b). So we assume the droplets do not have time to dry out. There is no test of fit to the face, so no requirement that a surgical mask fits well with few gaps for air to bypass the mask.

Another standard for masks is the F2100 standard of ASTM International (ASTM International Citation2021b). This has similar BFE requirements to the European Type II standard but in addition uses a test aerosol of 0.1 µm latex spheres. For example, the Level 3 standard F2100 standard requires that these particles must filter out with at least 98% efficiency. This is in addition to a BFE of at least 98%. So the requirements on the filtration properties are more stringent than for the Type II standard. However, there is still no test of fit in this standard (ASTM International Citation2021b).

Note that standards such as FFP2 (and N95) are designed to specify a minimum protection to all dangerous aerosols, not just droplets we breathe out that may contain a virus. So for example, they may also be worn when airborne asbestos is present. While the standards for surgical masks are aimed at reducing the amount of bacteria breathed out, for a wearer in an environment such as an operating theater, that must be kept as sterile as possible.

1.3. Focus of this work

While there is much literature on filtration, the details of how the size-dependent effectiveness of masks affect airborne transmission is less well understood. There has been a vigorous debate on the role of particle size on transmission (Tellier Citation2009; Asadi et al. Citation2019; Vuorinen et al. Citation2020; Bourouiba Citation2020). But this has focused on the size-dependent dynamics of particles in the air we breathe, rather than the competing effects that aerosol particle size has on the viral dose versus the protection offered by a face covering.

Here we focus on the latter, and we aim to show the relative importance of mask fit and viral load on total protection. We quantify the most important factors in mask protection by incorporating available data from the literature into a single-unified model describing:

  1. How filtration depends on aerosol particle size. Section 2 is largely review where we outline filtration for a general audience.

  2. The size distribution of deposited (fine) aerosol particles 10 µm in diameter, encompassing both evaporation of exhaled aerosols before inhalation and the probability that these are deposited in the respiratory tract upon inhalation.

  3. How the viral load in the exhaler’s respiratory fluid affects the size distribution of deposited viral aerosol particles.

  4. Finally, the expected overall reduction in deposited viral aerosol particles from mask interventions under the combination of these effects.

Note that we are interested in the overall protection offered to a community rather than just an individual; we therefore explore the effect of masking the exhaler (“source control”) in addition to the inhaler.

We find that the final protection offered varies significantly depending on the mask material (including the number of layers in the cloth masks), the face seal and the degree of viral shedding. The first factor has been reasonably well-explored during the pandemic (Zangmeister et al. Citation2020; Konda et al. Citation2020a; Lustig et al. Citation2020; Hao et al. Citation2020), but the latter two factors have been underappreciated in our opinion. A poorly fitted mask will offer limited protection, as aerosol particles can bypass the mask material(Freitag et al. Citation2020; Duncan et al. Citation2020). Finally, we show that the amount of viable virus prevented from being inhaled by a susceptible individual depends on the size distribution of respiratory particles and the viral load of the exhaler.

2. Masks are personal air filters

Masks are air filters, and how these work and how efficient they are at filtering out particles of differing sizes are reasonably well understood (Robinson et al. Citation2021; Wang and Otani Citation2013). Coarser aerosol particles with diameter 1 µm, which are more capable of containing significant viral doses (cf. section 3.3), are more easily filtered; finer particles ∼0.1 to 1 µm by contrast are transported around the fiber by the gas flow. We illustrate this schematically in .

Figure 1. Variation in mask filtration efficiency with incoming particle size. (a) Diagram of capture of viral particles by a fiber within a mask. Larger particles are more easily captured because they are less mobile; smaller aerosol particles by contrast are transported around the fiber by the gas flow. Larger particles can also carry more virions, and submicron aerosol particles are unlikely to contain even a single virion (cf. text). The filtration efficiency of perfectly fitting (b) N95/FFP2 masks, (c) surgical masks, and (d) cloth masks formed from 4 identical plain-woven cotton layers are shown as a function of particle size. We show experimental measurements from Zangmeister et al. (Citation2020); Oberg and Brosseau (Citation2008) (points) and predictions from our model (lines) which does not use fitting parameters and is described elsewhere (Robinson et al. Citation2021). The shaded envelopes around the lines in (c)–(d) show the uncertainty in the model predictions, obtained by propagating uncertainties in the geometric parameters given in Zangmeister et al. (Citation2020). We set the velocity of the gas through the mask to 6.3 cm s− 1 in our calculations for comparison with data from Zangmeister et al. (Citation2020).

Figure 1. Variation in mask filtration efficiency with incoming particle size. (a) Diagram of capture of viral particles by a fiber within a mask. Larger particles are more easily captured because they are less mobile; smaller aerosol particles by contrast are transported around the fiber by the gas flow. Larger particles can also carry more virions, and submicron aerosol particles are unlikely to contain even a single virion (cf. text). The filtration efficiency of perfectly fitting (b) N95/FFP2 masks, (c) surgical masks, and (d) cloth masks formed from 4 identical plain-woven cotton layers are shown as a function of particle size. We show experimental measurements from Zangmeister et al. (Citation2020); Oberg and Brosseau (Citation2008) (points) and predictions from our model (lines) which does not use fitting parameters and is described elsewhere (Robinson et al. Citation2021). The shaded envelopes around the lines in (c)–(d) show the uncertainty in the model predictions, obtained by propagating uncertainties in the geometric parameters given in Zangmeister et al. (Citation2020). We set the velocity of the gas through the mask to 6.3 cm s− 1 in our calculations for comparison with data from Zangmeister et al. (Citation2020).

We show experimental measurements for the filtering efficiency in medical-grade respirators from the literature in . Respirators are specialist materials typically composed of electret fibers; these fibers carry considerable electrostatic charge (Chen et al. Citation1993; Kravtsov et al. Citation2000) which increases the efficiency in the 0.1 to 1 µm regime. These charges diminish over time which will decrease the filtration efficiency. The results for the base fabric (squares) are for its uncharged state, and thus suggest a lower bound on the respirator’s efficiency after repeat use.

In we have plotted both measurements of surgical mask filtering efficiency (symbols) and theoretical calculations (curves). The theoretical calculations involved following the trajectories of particles inserted into the gas flow around fibers, described elsewhere (Robinson et al. Citation2021) and in the Supplementary Material (SM). The efficiency is plotted as a function of the particle diameter, because the particle size ultimately determines how hard or easy it is to filter out. Our model and the measurements of Zangmeister et al. (Citation2020) agree on the same basic facts:

  • Filtering efficiency is essentially 100% for particles 3 µm in diameter or larger.

  • However, filtering efficiency is low (3060 to %) in the range 0.1 to 1 µm.

These predictions make quantitative the picture we laid out in the preceding paragraph and . Both surgical and cotton masks are thus only partially effective at filtering out sub-micrometre aerosol particles. However, their efficiency rapidly increases as the size increases beyond a micrometre, so masks are generally highly effective in this regime. Note that there is considerable variation in mask quality, reflecting the many available standards. The “dental masks” A and C of Oberg and Brosseau (Citation2008) (shown in for reference) do not pass any mask standard (not even the less stringent BFE test at 3 µm) making them of very poor quality. Conversely, most of the surgical masks tested in Oberg and Brosseau (Citation2008); Duncan et al. (Citation2020) outperform the predictions of our theoretical profile and Zangmeister et al. (Citation2020).

For reference, SARS-CoV-2 is approximately 0.1 µm in diameter (Bar-On et al. Citation2020), so any particle larger than this can potentially carry a virus. However, in the next section we will argue that only particles larger than 1 µm are likely to contain any virus in the majority of cases; thus filtration efficiency in this regime is sufficient to significantly reduce transmission.

Surgical masks are meshes of fibers (cf. ), whereas cloth face coverings are typically more ordered (e.g., woven fabric in ). In we compare measurements and model predictions for the material of two masks formed from 4 layers of plain-woven cotton fabrics Zangmeister et al. (Citation2020). There is considerable variation, but for the best fabric the behavior is more-or-less identical to surgical masks; this is broadly in agreement with the findings of Zangmeister et al. (Citation2020); Konda et al. (Citation2020a); Lustig et al. (Citation2020); Wang (Citation2020) and demonstrates that reusable cloth masks can be suitable replacements for disposable surgical masks.

Figure 2. Fabrics are broadly categorized as knitted (not shown), woven or non-woven. (a) Woven fabrics formed by intersecting perpendicular yarns (the “warp” and “weft”). (b) Nonwoven fabrics are formed by entangling fibers through other means, resulting in less ordered arrangements. Scanning electron microscope images of example fabrics show scalebars of (a) 100 µm and (b) 50 µm.

Figure 2. Fabrics are broadly categorized as knitted (not shown), woven or non-woven. (a) Woven fabrics formed by intersecting perpendicular yarns (the “warp” and “weft”). (b) Nonwoven fabrics are formed by entangling fibers through other means, resulting in less ordered arrangements. Scanning electron microscope images of example fabrics show scalebars of (a) 100 µm and (b) 50 µm.

Returning to the mechanism, we briefly discuss the physics underlying this behavior (more details can be found in Robinson et al. (Citation2021)). Masks are fundamentally arrays of fibers, see , so air must flow around and between these fibers. Particles a fraction of a micrometre in size have very little inertia and so tend to follow the air flow through the mask faithfully avoiding the fibers. However, the particle inertia varies with its mass, i.e., the cube of its diameter (its volume). This means it rapidly increases with diameter. Beyond around 1 µm in diameter the particles have too much inertia to follow the air as it twists in between the fibers, and so they impact onto the fibers. On microscopic lengthscales most surfaces are attractive, so colliding particles will stick and remain on the fibers (Robinson et al. Citation2021). Because of this basic physics, the filtering efficiency of particles larger than 3 µm is likely to be limited only by the leakage of air around the mask. For the intermediate range 1 to 3 µm the exact behavior will depend on the details of the material, but the rapid rise in filtration efficiency with particle size is a robust feature (Robinson et al. Citation2021). Finally, we note that the filtration efficiency increases for capture of the smallest aerosol particles (0.3 µm) in where capture is enhanced by Brownian motion. We have not focused on this mechanism because such small particles are highly unlikely to carry significant doses of virus.

3. Size distribution of fine respiratory aerosol particles involved in airborne transmission

To assess the effect of mask wearing we need to know which respiratory aerosol particles are likely to carry significant doses of virus. We thus need to know the size distribution of particles on exhalation and inhalation, and how concentrated the (viable) virus is in aerosols produced by shedding in an infected individual.

3.1. Size distribution of bioaerosol particles

We need the size distribution of particles on inhalation and exhalation. The former are obtained from the latter through knowledge of the evaporation kinetics, so we begin with exhaled particles.

Expiratory particles can be meaningfully categorized by their site of origin in the respiratory system. Larger particles are more likely to be deposited in the respiratory tract (Zhang et al. Citation2012; Cheng Citation2014; Chalvatzaki et al. Citation2020; Guo et al. Citation2020), so a large aerosol particle originating deep in the respiratory tract would immediately deposit and be unlikely to escape; therefore as a rule, smaller exhaled aerosol particles emerge from lower in the respiratory tract. The majority of aerosol particles (and droplets) produced in the oral cavity vary in size from ∼10 to 1000 µm (Johnson et al. Citation2011), whereas particles produced in the Larynx and the lower respiratory tract are seen in the range ∼0.1 to 10 µm (Morawska et al. Citation2009; Johnson et al. Citation2011; Asadi et al. Citation2019; Gregson et al. Citation2021). The former presumably contain the majority of virus because volume scales as the diameter cubedFootnote1, but the latter will be our focus for reasons laid out in the introduction.

Fluid particles immediately begin to evaporate upon exhalation (Xie et al. Citation2007; Liu et al. Citation2017) and aerosol particles smaller than 10  µm will reach their dessicated steady states (which we will refer to as “nuclei”) in less than 1 s (Nicas et al. Citation2005). We take parameterisations of the measured size distributions (i.e., uncorrected for evaporation) reported in Johnson et al. (Citation2011); Gregson et al. (Citation2021) as the unperturbed (by masking) inhaled distribution pin(0) in our calculations. Their hydrated state would be around a factor of 3 larger on exhalation, allowing for coverings to filter aerosol particles more effectively at the source (Liu et al. Citation2017; Robinson et al. Citation2021). We therefore write the distribution of exhaled particle diameters D as (1) pex(D)pin(0)(3D).(1)

We show the size distributions expected on inhalation and exhalation in . We see that the bigger aerosol particles on exhalation more strongly overlap with the region where surgical masks filter effectively (without mask leakage). In the same figure we also show the size distribution of FFP2 test aerosolsFootnote2, which are much finer on average. NB: we work in log-space for D (in µm), so these distributions are probability densities where p{in,ex} dln(D/µm) are the infinitesimal probabilities. p{in,ex}(D) therefore have no units.

Figure 3. Aerosol distributions relevant to masking: respiratory aerosols and the test aerosol used in FFP2 standards testing. We show the theoretical filtration profile of the surgical mask in for reference. Aerosol particles are coarser on exhalation (solid) than inhalation (dashed) because of evaporation, and so the exhaled size distribution overlaps more strongly with the region where masks filter effectively (dotted line and blue shaded region). The test aerosol (dash-dotted) contains primarily finer particles than are generally found in respiratory aerosols.

Figure 3. Aerosol distributions relevant to masking: respiratory aerosols and the test aerosol used in FFP2 standards testing. We show the theoretical filtration profile of the surgical mask in Figure 1c for reference. Aerosol particles are coarser on exhalation (solid) than inhalation (dashed) because of evaporation, and so the exhaled size distribution overlaps more strongly with the region where masks filter effectively (dotted line and blue shaded region). The test aerosol (dash-dotted) contains primarily finer particles than are generally found in respiratory aerosols.

3.2. Perturbation of inhaled aerosol distribution by masks

We write ϕ{ex,in} as the penetration through the mask (i.e., the fraction of particles let through) on exhalation/inhalation. We account for mask leakage α by setting (2) ϕ(D;α)=α+(1α)ϕ(D;α=0)(2) and we assume mask leakage to be independent of particle size D. We obtain ϕ(D;α=0) by subtracting the theoretical mask filtration shown in from 1. Setting α = 1 on inhalation or exhalation effectively removes the respective mask within this model. Mask leakage varies considerably, especially for surgical masks (Duncan et al. Citation2020). Estimates of α vary from around ∼20 to 30% in Hossain et al. (Citation2020); Grinshpun et al. (Citation2009) to as high as ∼40 to 50% in masks with artificial leaks(Rengasamy et al. Citation2014). In general we expect α to be greater on exhalation than inhalation, because breathing affects the face seal, and therefore to vary with, e.g., breathing pattern (Grinshpun et al. Citation2009). For simplicity, we neglect these effects and keep α as a constant. Initially we develop our model assuming α = 0, before we consider the impact of leakage α>0 later in section 4; for our current purposes it is enough to say that leakage effects are included in the definition of Equation(2).

Accounting for masks, the inhaled size distribution becomes (3a) pin(D)ϕin(D)ϕex(3D)1Rinpin(0)(D),(3a) where the total (number) fraction of inhaled particles removed by the masks is (3b) Rin10ϕin(D)ϕex(3D) pin(0)(D) dln(D μm).(3b)

In we show the results for the fraction of respiratory aerosol particles removed by a perfectly fitting (i.e., α = 0) surgical mask assuming the theoretical filtration profile of . We also show the results for an FFP2 test aerosol for reference, which involves finer particles and so underpredicts the mask efficacy if one is really only interested in the respiratory aerosols.

Table 1. Expected efficacy of perfectly fitting surgical masks at removing aerosol particles with various size distributions. We assume the theoretical filtration profile for the surgical masks shown in . In practice, mask leakage would reduce the fraction removed. These numbers are expected to be similar for (perfectly fitting) multi-layered cloth masks (cf. ).

The official FFP2 test measures effectiveness by mass (rather than number) weighting (European Committee for Standardization Citation2019a). Weighting pin(0) by D3 in Equation(3) gives the aerosol mass distribution, which may be more relevant for estimating inhaled viral dose, and the fraction of aerosol particles removed by mass. Mass weighting preferences larger particles and improves the fraction removed in , though this improvement is less pronounced for the FFP2 test aerosol because these coincide with the window where masks are poor filters. An FFP2 test would fail this surgical mask which only filters 65.1% by mass, even though it would filter ∼99% of the fine particles exhaled during speech or coughing (with perfect face seal).

3.3. Accounting for biological factors: Viral load and deposition

For an aerosol particle to be a possible disease vector it must (i) contain at least one (viable) virion, and (ii) deposit in the respiratory tract upon inhalation. We will model these two effects and show how they shift the relevant part of the inhaled size distribution to coarser aerosol particles, which has positive implications for practical mask effectiveness.

Testing for SARS-CoV-2 is primarily performed by detecting the presence of viral RNA in respiratory fluid using reverse-transcriptase polymerase chain reaction (RT-PCR). The distribution of concentrations of viral RNA, the viral load, using this technique has been reported in Jones et al. (Citation2021b); Jacot et al. (Citation2020) which we show in . The distribution is extremely broad, spanning around 10–12 orders of magnitude: patients in the upper tail of the distribution (the “superreplicators”) may be a factor in superspreading events. Finally, we note that there is ample time for evaporation between sample collection and testing in these studies so we assume these concentrations to refer to the dessicated states (the nuclei).

Figure 4. Histograms of key properties of expiratory particles, i.e., normalized so that the area under the curves gives the relative frequency. (a) Distributions of SARS-CoV-2 viral loads in testing from RT-PCR in two studies (Jones et al. Citation2021b; Jacot et al. Citation2020) (points) and our bimodal fits for calculating percentiles (lines). Note the large distribution, and the presence of a tail of patients with extraordinarily large viral loads (shaded purple) corresponding to so-called “superreplicators”. (b)–(c) Aerosol distributions for virus-laden particles exhaled during speech and voluntary coughing under viral loads typical of the top 25th percentile in (a). We show the distributions of inhaled aerosols that contain at least one virus (solid lines) and those that bypass a perfectly fitting surgical mask worn by the inhaler (dashed lines); the latter are unnormalized to show the effect of filtering. We calculate the former distributions using data from Gregson et al. (Citation2021); Johnson et al. (Citation2011) to characterize the exhaled aerosol particles in healthy patients.

Figure 4. Histograms of key properties of expiratory particles, i.e., normalized so that the area under the curves gives the relative frequency. (a) Distributions of SARS-CoV-2 viral loads in testing from RT-PCR in two studies (Jones et al. Citation2021b; Jacot et al. Citation2020) (points) and our bimodal fits for calculating percentiles (lines). Note the large distribution, and the presence of a tail of patients with extraordinarily large viral loads (shaded purple) corresponding to so-called “superreplicators”. (b)–(c) Aerosol distributions for virus-laden particles exhaled during speech and voluntary coughing under viral loads typical of the top 25th percentile in (a). We show the distributions of inhaled aerosols that contain at least one virus (solid lines) and those that bypass a perfectly fitting surgical mask worn by the inhaler (dashed lines); the latter are unnormalized to show the effect of filtering. We calculate the former distributions using data from Gregson et al. (Citation2021); Johnson et al. (Citation2011) to characterize the exhaled aerosol particles in healthy patients.

Viral load typically peaks around the onset of symptoms (Zou et al. Citation2020) which is also the most contagious stage of disease progression (Anderson et al. Citation2020); we thus expect viral loads from the upper half of the distributions in to be most relevant to disease transmission. The actual number of viable virus, as measured from viral plaque assays, in aerosol vs the RT-PCR result is typically only one part in 102 to 104 (Milton et al. Citation2013; Fears et al. Citation2020). We can thus take the upper limit of (naso-oral) viral loads as 108 to 1010  ml1 instead of 1010 to 1012  ml1.

These RT-PCR studies primarily involved testing naso- and oropharyngeal samples, which are presumably diluted by saliva and other fluids. Fluids from the lower respiratory tract may be more concentrated with virus, especially when viral replication occurs there in advanced stages of the disease. Viral loads larger than 108 to 1010  ml1 may therefore be relevant to airborne transmission We will find that factoring in viral load changes mask effectiveness in a sharp step function, and so any variation in viral load through the respiratory tract is less important than where it is most concentrated. As data on viral concentration in the lower respiratory tract is lacking, we can only discuss this possibility without factoring in the difference quantitatively.

The probability that an aerosol particle contains at least one virus depends on its volume and the viral load. By combining this information we can estimate the fraction of particles at any specific size that contains the virus, and thus the variation in the relative number of particles that contain the virus across the size distribution.

The average number of virions nv in a particle is (assuming homogeneity) simply its volume times the viral load v of the respiratory fluid. This yields nv=vπD36. assuming spherical particles. Assuming the Poisson distribution, the probability that a particle of this size contains at least one virion is Pin(v|D)=1env.

This describes a step function in D and v with negligible probability for D1 μm and v108 ml1. Pin(v|D) is only ∼4% for D=1 μm and v=108 ml1, and rapidly diminishes further with decreasing D or v. Applying Bayes’ theorem gives the size distribution of aerosol particles containing at least one virus as (4) pin(D|v)Pin(v|D) pin(D),(4) with a proportionality constant to ensure the distribution is normalized. The quantity pin(D) is the distribution of all inhaled aerosol particles (i.e., viral or otherwise) in the presence of masking, i.e., Equation(3), that we considered in section 3.2. In and we show the resulting distributions produced in speech and coughing. For the moderately large viral load of 108 ml1 the majority of viral aerosol particles are distributed in the micron regime 1 μm. Only for extremely large viral loads of 1010  ml1 do the submicron aerosol particles begin to contain significant numbers of virus.

Our formalism focuses on the number distribution of aerosol particles, but it gives the mass distribution in the limit of small viral loads. In this limit we find Pin(v|D)=nv+O(v2), and so Equation(4) becomes (5) pin(D|v)D3 pin(D)+O(v2),(5) i.e., we obtain a mass-weighted inhaled distribution. This is the appropriate weight function for calculating the inhaled mass (or dose), and so we can estimate the reduction in viral dose from masking as the small v result in our model, e.g., in Equation(3).

As the second biological effect, we consider only those aerosol particles which would actually deposit in the respiratory tract. We show the probability of aerosol particles being deposited in the respiratory tract Pdep, using the data from Chalvatzaki et al. (Citation2020), in . We simply take Pdep as the total probability shown in , ignoring the site of deposition; we note however that the deposition site is potentially important in determining the severity of potential infection and so the model could be extended with further information on site-dependent risk. Most of the fine aerosol particles ∼0.1 to 1 µm are simply re-exhaled after inhalation(Chalvatzaki et al. Citation2020), which we can build into our model. Applying Bayes’ theorem again, we obtain the size distribution of inhaled aerosol particles that deposit in the respiratory tract as (6) pdep(D)Pdep(D) pin(D),(6) with a proportionality constant to ensure the distribution is normalized. This effect shifts the size distribution to coarser aerosol particles, as shown in .

Figure 5. Effect of deposition on the size distribution of aerosol particles received in the respiratory tract of the inhaler. Fine aerosol particles with diameters ∼0.1 to 1 µm are unlikely to deposit in the respiratory tract, shifting the effective aerosol particle size distribution of concern to coarser particles. (a) Probability of deposition Pdep at various sites in the respiratory tract, showing experimental data (points) from Chalvatzaki et al. (Citation2020) and our quadratic interpolation (lines). (b) Probability density for inhaled bioaerosol particles from Gregson et al. (Citation2021); Johnson et al. (Citation2011) (solid lines), and the probability density of those aerosol particles which actually deposit in the respiratory tract (dashed lines) after conditioning on data in (a).

Figure 5. Effect of deposition on the size distribution of aerosol particles received in the respiratory tract of the inhaler. Fine aerosol particles with diameters ∼0.1 to 1 µm are unlikely to deposit in the respiratory tract, shifting the effective aerosol particle size distribution of concern to coarser particles. (a) Probability of deposition Pdep at various sites in the respiratory tract, showing experimental data (points) from Chalvatzaki et al. (Citation2020) and our quadratic interpolation (lines). (b) Probability density for inhaled bioaerosol particles from Gregson et al. (Citation2021); Johnson et al. (Citation2011) (solid lines), and the probability density of those aerosol particles which actually deposit in the respiratory tract (dashed lines) after conditioning on data in (a).

To summarize this section, there is considerable biological variation in how the virus is shed. Assuming the virus concentration depends only on the site of origin in the respiratory tract, then this concentration becomes independent of size for the fine aerosol particles. On physical grounds, we then expect the vast majority of the finest aerosol particles 1 μm to be empty of virus and/or to not actually deposit in the respiratory tract. These fine particles are therefore only expected to carry concerning doses in a small minority (5%) of infected individuals who shed orders-of-magnitude more virus than average. Similar conclusions were recently reached by Freitag et al. (Citation2020).

4. Overall mask effectiveness

To gauge overall mask effectiveness in preventing airborne transmission, we modify the (number) fraction of droplets removed Equation(3) to focus on just those relevant to disease transmission. That is, those aerosol particles that (i) contain at least one virion and (ii) deposit in the respiratory tract of the inhaler. We presented those calculations in section 3.3 and show their effects on the particle size distribution in and .

Accounting for these effects, the aerosol particle size distribution of concern becomes (7a) pdep(D|v)ϕin(D)ϕex(3D)1RvecPdep(D)Pin(v|D)1Rdep,vpin(0)(D),(7a) where the total (number) fraction of vector particles (i.e., viral aerosol particles that deposit) removed by the masks is (7b) Rvec10(ϕin(D)ϕex(3D) pin(0)(D)Pdep(D)Pin(v|D)1Rdep,v) dln(D μm),(7b) and the (number) fraction of inhaled particles ignored because they do not deposit or contain virus is (7c) Rdep,v=10Pdep(D)Pin(v|D) pin(0)(D) dln(D μm).(7c)

shows the net result of mask effectiveness Rvec against viral load under various masking scenarios. In all scenarios the (number) fraction removed is seen to be a step function in decreasing mask effectiveness as (viable) viral loads vary over ∼107–1011 ml1. Masks are more effective with smaller viral loads because the virus-laden aerosol particles are larger, as we saw in ). In all cases this effect is further enhanced by the low-likelihood of deposition in the respiratory tract, accounting for which shifts the relevant size distribution to coarser aerosol particles and enhances mask effectiveness.

Figure 6. Number fraction of viral aerosol particles (i.e., those containing at least one virus) from an infected exhaler that are prevented from being deposited into the respiratory tract of the inhaler, considered where (a) only the inhaler is masked, (b) only the exhaler is masked and (c) both are masked. The upper limits at small viral loads correspond to the mass fraction (i.e., the depositing viral dose) removed. In all three scenarios the effect of constant mask leakage is examined, and we assume: (i) a surgical mask with the theoretical filtration profile of , (ii) the bioaerosol particle size distributions shown in , and (iii) the deposition probabilities of . Biological variation affects the practical mask effectiveness, but the effect of mask leakage predominates.

Figure 6. Number fraction of viral aerosol particles (i.e., those containing at least one virus) from an infected exhaler that are prevented from being deposited into the respiratory tract of the inhaler, considered where (a) only the inhaler is masked, (b) only the exhaler is masked and (c) both are masked. The upper limits at small viral loads correspond to the mass fraction (i.e., the depositing viral dose) removed. In all three scenarios the effect of constant mask leakage is examined, and we assume: (i) a surgical mask with the theoretical filtration profile of Figure 1c, (ii) the bioaerosol particle size distributions shown in Figures 4b and c, and (iii) the deposition probabilities of Figure 5a. Biological variation affects the practical mask effectiveness, but the effect of mask leakage predominates.

As the effect of viral loads is seen as a step function, we plot the resulting range of values (i.e., Rvec at small and large v) against mask leakage in . In all scenarios, masking the exhaler is better than masking the inhaler, because particles are larger on exhalation and thus easier to filter; however, masking both is optimal. Increasing mask leakage generally has a strongly negative performance effect, especially on inhalation. For mask leakage α, the best possible mask performance is (1α)Rvec(α=0) when one person is masked and (1α2)Rvec(α=0) when both are masked; these theoretical values are shown as dashed lines in . However, and show that practical mask performance may be worse after considering the interplay of filtration with biological effects, especially when only the inhaler is masked. This is because large viral loads increase the risk of transmission by submicron aerosol particles where mask filtration is poor.

Figure 7. Effect of mask leakage on (number) fraction of vector aerosol particles (see text and ) removed for two exhalation modes. The filled envelopes indicate the range of expected values from varying viral load as in . The upper limits are equivalent to the mass fraction (i.e., depositing viral dose) removed. We show the expected performance for perfect filtration media (dashed lines) for two masks (black) and one mask (orange). We assume: (i) a surgical mask with the theoretical filtration profile of , (ii) the bioaerosol particle size distributions shown in , and (iii) the deposition probabilities of .

Figure 7. Effect of mask leakage on (number) fraction of vector aerosol particles (see text and Figure 6) removed for two exhalation modes. The filled envelopes indicate the range of expected values from varying viral load as in Figure 6. The upper limits are equivalent to the mass fraction (i.e., depositing viral dose) removed. We show the expected performance for perfect filtration media (dashed lines) for two masks (black) and one mask (orange). We assume: (i) a surgical mask with the theoretical filtration profile of Figure 1c, (ii) the bioaerosol particle size distributions shown in Figures 4b and c, and (iii) the deposition probabilities of Figure 5a.

While we have focused on number fraction, the low viral load limit yields the expected result for the reduction in mass fraction (see discussion around Equation(5)). The mass fraction reduction estimates the reduction in viral dose transmitted. Masks perform best in this limit, because coarser particles carry more mass. The upper limit of the envelopes in shows that in terms of viral dose reduction, masking almost performs as well as the ideal results (dashed curves) under conditions where the exhaler or both are masked. If disease transmission depends on dose alone, then the filtration profile of the surgical mask in is essentially perfect and the only limitations are (i) individual mask leakage and (ii) population adherence to mask wearing.

5. Discussion

We have seen that mask effectiveness crucially depends on the size of aerosol particles which act as disease vectors, even for fine particles 10 μm in diameter. At smaller viral loads, the virus-laden aerosol particles are coarser making masks more effective; conversely, at large viral loads submicron particles can carry virus which coincides with the size regime where mask materials have their poorest filtration properties. The available data from Jones et al. (Citation2021b); Jacot et al. (Citation2020) indicates that such large viral loads are extremely rare in the oral-naso fluid of SARS-CoV-2 patients, which would suggest that the coarser aerosol particles 1 µm are more important for disease vectors, and that masks would perform better in practice than, e.g., an FFP2 test would predict. However, we are unaware of any data on viral loads in fluid taken from deeper in the respiratory tract, where it may be more concentrated, and so submicron particles remain potential transmission vectors. Considering this key unknown, we are only able to set upper and lower bounds on the (number) fraction of viral aerosol particles removed.

Taken together, our calculations suggest that mask effectiveness depends more on mask leakage than it does on the other variables. Considering effectiveness for normal speech , we find that the surgical mask of Zangmeister et al. (Citation2020) with 50% mask leakage would only filter 62 to 73% of vectors (by number) when worn by both. The upper limit (corresponding to low viral loads) is already close to the best possible performance of 75% obtainable through perfect filtration. Improving the mask material is therefore insignificant compared to the benefit of improving the fit: keeping the material the same, but reducing leakage to 5% would yield mask performances of 92 to 99%. In a similar vein, ensuring both inhaler and exhaler are masked will outperform any gains in mask filtration when leakage is assumed; the lower limit of 62% at large viral loads already exceeds the theoretical best performance of a single mask of 50% at 50% leakage.

These findings have implications for surgical and fabric mask standards. As discussed, the FFP2 test samples the submicrometer size regime which may not always be relevant for airborne transmission and thus may be too stringent as a test. Conversely, the BFE test used for medical face masks featuring 3 µm aerosol particles may be too large and also sampling the region where mask material properties are likely to be poor; this may be too relaxed as a test. Moreover, no standards for surgical and fabric masks include tests for fit, even though we have seen this to be a crucial limiting factor in their effectiveness at curbing disease transmission.

Finally, we note that our model is subject to the following limitations:

  • We only consider the number of aerosol particles, i.e., we are agnostic to the dose delivered or the dose-response. Our model is very conservative in this sense: weighting the size-distributions by particle volume to capture dose would increase the predicted effectiveness by selecting coarser particles which masks are better at filtering. A consequence of this modeling choice is that mask effectiveness is a step function in the viral load. Focusing instead on dose would improve the expected mask effectiveness, and in fact corresponds to the upper limit of effectiveness in our model (see discussion around (5)). Our stricter model allows for disease transmission to involve a kinetics depending on the number of virus-carrying particles received. Even with our conservative estimate, shows that the filtration profile of surgical masks in Zangmeister et al. (Citation2020) is likely ‘good enough’ to achieve almost ideal performance in practice is suggestive that (i) mask leakage and (ii) universal masking are more important factors than material properties.

  • We assumed mask leakage to be independent of particle size. This would be straightforward to improve this by making α dependent on D in (2).

  • We lack data on the viral loads in the lower respiratory tract. As a consequence we can only provide upper and lower bounds on mask effectiveness.

  • Our mask effectiveness Rvec measures the reduction in exposure to potential disease vectors relative to when no masks are worn. As viral load increases, the absolute dose received (and thus the risk of transmission) increases even after Rvec has reached its plateau value (cf. ).

  • We have not focused on coarse aerosol particles 10 µm which have much shorter sedimentation times. Mask filtration is essentially perfect for these particles so other factors related to masking are more important such as the way masks deflect and remove momentum from expiratory jets (Tang et al. Citation2009, Citation2011).

  • We have assumed a constant flow velocity of 6.3 cm s− 1 through our masks to match Zangmeister et al. (Citation2020). This neglects changes in flow velocity during tidal breathing, which will in turn be affected by the breathing pattern (and factors such as physical activity) which has a complex effect on mask performance (Grinshpun et al. Citation2009). For simplicity we have neglected this, but an interesting extension of our model could consider the integrated effectiveness with variable flow velocity.

6. Conclusion

We have presented a model for practical mask performance, as measured by the (number) fraction of potential disease vectors removed. Our model combines a mask’s material filtration and leakage with three biological factors: (i) the distribution of respired aerosol particles, (ii) the viral load of the exhaler and (iii) the probability of deposition in the respiratory tract of the inhaler. We found that masks do protect the wearer, but perform best as source control; in any case, masking both exhaler and inhaler is best. But not all masks are the same. A mask meeting a Personal Protective Equipment (PPE) standard such as the European FFP2 standard should filter out at least 92% of the virus. The standard specifies 92% filtration for a test aerosol that is smaller and harder to filter than the droplet sizes we expect to be most dangerous.

A surgical mask meeting the European Type II standard may be made of material which filters significantly less of the virus. For example, we predict that the material of one of the surgical masks studied by Zangmeister and coworkers (Zangmeister et al. Citation2020), on inhalation filters 88% of the mass of speech droplets, see . The material of an FFP2 or similar mask will filter out close to 100%. But the bigger problem with surgical mask standards is that they do not specify fit, and so many surgical masks fit poorly. Grinshpun and coworkers (Grinshpun et al. Citation2009) found that approximately 30% of the air bypassed the material of the surgical mask they tested. With this poor a fit, the filtration is only 0.7×88%=62%. This is enough to reduce transmission, but is inferior to an FFP2 mask. Respirators offer both superior fit and superior filtration of smaller aerosol particles, and so replacing surgical masks with FFP2, N95, or similar respirators will increase the protection of both healthcare workers and the public.

Following the emergence of more infectious variants of SARS-CoV-2, some policy makers have mandated the wearing of respirators in public spaces (Deutsche Welle Citation2021). As a complementary approach, policy makers could pursue a strategy of improving the quality of masks worn in community settings. Practical guidance on reducing leakage would therefore be required to pursue this strategy. For example, Duncan et al. (Citation2020) found that surgical masks sealed via tie straps offered better face sealage than ear loops. The filtration properties of fabric can be poor (Konda et al. Citation2020b; de Anda et al. Citation2022), but their fit can be better than that of surgical masks (Duncan et al. Citation2020) and they can in principle be tailored to the wearer. There are no standards for fabric masks apart from the recent F3502 standard (ASTM International Citation2021a), which does not set a standard for mask fit. Washable cloth masks have the additional advantage of being more environmentally friendly than surgical masks and respirators, which are made from plastic fibers.

Surgical mask standards like the European Type II standard (EN 14683) are not adequate for a COVID-19. There is no requirement on mask fit, and filtration performance of the material is measured at the too-large diameter of 3 μm. The standard could be made fit for purpose by specifying filtration as worn, as in the FFP2 standard, and measuring filtration at particle sizes around 1 μm or smaller. Alternatively, surgical mask standards could be removed entirely, leaving only FFP2 and similar standards. In either case, changing the standard could drive up the protection offerered by masks, and so reduce COVID-19 transmission.

Transmission of respiratory viruses is complex and poorly understood, so more data is needed. We need either direct data on transmission rates as a function of conditions, with and without masks, and a much better idea of the infectivity of aerosolised virus including the required dose for infection. Both of these will be challenging but both are possible. The basic physics of filtration tells us about how capture varies with aerosol particle size, and so once we have this data we can easily update our estimates of the protection offered by masks.

It now seems well established that with SARS-CoV-2 some infected people have viral loads thousands or millions of times higher than others (Jones et al. Citation2021b; Jacot et al. Citation2020). Thus a 50% reduction in dose due to mask wearing corresponds to very different absolute reductions in dose from infected people with high and low viral loads. As typically the viral load of an infectious person will not be known, other forms of interventions are warranted in addition to masking.

Acknowledgments

The authors wish to thank Kate Oliver for helpful discussions on textiles, Patrick Warren for guidance on LB simulations, Mahesh Bandi for making us aware of his ingenious use of a candyfloss maker, and Mike Allen, Jens Eggers, and Daan Frenkel for helpful discussions. We gratefully acknowledge Daniel Bonn, Patrick Charbonneau, K. K. Cheng, Rosie Dalzell, Tanniemola Liverpool, John Russo and Hajime Tanaka for providing valuable comments on this work. We would also like to thank the two reviewers for very useful and constructive comments on the submitted manuscript.

JFR, JPR and CPR wish to thank the Bristol Aerosol COVID-19 group for valuable discussions and feedback on this work. JFR would like to thank Kirsty Wynne for assistance in debugging the code used in the theoretical calculations.

We thank E. Chalvatzaki and M. Lazaridis for sharing their data on the probability of aerosol particle deposition in the respiratory tract.

Data availability statement

The data presented as results in this study were obtained using a computer code which implements the methods outlined in the text. This code is freely available at Robinson and Sear (Citation2021).

Additional information

Funding

The authors would like to thank Judith Mantell and Jean-Charles Eloi of the Wolfson Bioimaging Facility and the Chemical Imaging Facility (EPSRC Grant “Atoms to Applications”, EP/K035746/1), respectively, for the SEM images and assistance in this work.

Notes

1 The concentration of viable virus may be lower in oral-mode droplets: in influenza it is a factor of  10 smaller (Milton et al. Citation2013), however even accounting for this a factor of 10 increase in diameter increases the expected number of virions by 100.

2 The FFP2 standard (European Committee for Standardization Citation2019a) specifies the test aerosol has a (number) median diameter between 0.06 to 0.10 µm with a geometric standard deviation between 2.0 to 3.0. We therefore model the FFP2 test aerosol size distribution as a log-normal with a median of 0.08 µm and a geometric standard deviation of 2.5.

References

  • Anderson, E. L., P. Turnham, J. R. Griffin, and C. C. Clarke. 2020. Consideration of the aerosol transmission for COVID-19 and public health. Risk Anal. 40 (5):902–7. doi:10.1111/risa.13500.
  • Asadi, S., A. S. Wexler, C. D. Cappa, S. Barreda, N. M. Bouvier, and W. D. Ristenpart. 2019. Aerosol emission and superemission during human speech increase with voice loudness. Sci. Rep. 9 (1):2348. doi:10.1038/s41598-019-38808-z.
  • ASTM International. 2021a. Standard specification for performance of materials used in medical face masks. F3502 - 21.
  • ASTM International 2021b. Standard specification for performance of materials used in medical face masks. Technical Report F2100 - 21.
  • Bar-On, Y. M., A. Flamholz, R. Phillips, and R. Milo. 2020. SARS-CoV-2 (COVID-19) by the numbers. eLife 9:e57309. doi:10.7554/eLife.57309.
  • Bazant, M. Z., and J. W. M. Bush. 2020. A guideline to limit indoor airborne transmission of COVID-19. Proc. Natl. Acad. Sci. USA 118 (17):e2018995118. doi:10.1073/pnas.2018995118.
  • Bourouiba, L. 2020. Turbulent gas clouds and respiratory pathogen emissions: Potential implications for reducing transmission of COVID-19. JAMA 323 (18):1837–38. doi:10.1001/jama.2020.4756.
  • Bourouiba, L., E. Dehandschoewercker, and J. W. M. Bush. 2014. Violent expiratory events: On coughing and sneezing. J. Fluid Mech. 745:537–63. doi:10.1017/jfm.2014.88.
  • Buonanno, G., L. Stabile, and L. Morawska. 2020. Estimation of airborne viral emission: Quanta emission rate of SARS-CoV-2 for infection risk assessment. Environ. Int. 141:105794. doi:10.1016/j.envint.2020.105794.
  • Chalvatzaki, E., S. E. Chatoutsidou, and M. Lazaridis. 2020. Simulations of the deposition of pharmaceutical aerosols in the human respiratory tract by dry powder inhalers (DPIs). J. Drug Delivery Sci. Technol. 59:101915. doi:10.1016/j.jddst.2020.101915.
  • Chen, C. C., M. Lehtimäki, and K. Willeke. 1993. Loading and filtration characteristics of filtering facepieces. Am. Ind. Hyg. Assoc. J. 54 (2):51–60. doi:10.1080/15298669391354324.
  • Cheng, Y. S. 2014. Mechanisms of pharmaceutical aerosol deposition in the respiratory tract. AAPS PharmSciTech 15 (3):630–40. doi:10.1208/s12249-014-0092-0.
  • Dai, H., and B. Zhao. 2020. Association of the infection probability of COVID-19 with ventilation rates in confined spaces. Build. Simul. 13 (6):1321–7. doi:10.1007/s12273-020-0703-5.
  • Dancer, S. J. 2020. Covid-19 exposes the gaps in infection prevention and control. Infect. Dis. Health. 25 (4):223–6. doi:10.1016/j.idh.2020.08.005.
  • Dbouk, T., and D. Drikakis. 2020. On respiratory droplets and face masks. Phys. Fluids 32 (6):063303. doi:10.1063/5.0015044.
  • de Anda, I. R., J. W. Wilkins, J. F. Robinson, C. P. Royall, and R. P. Sear. 2022. Modelling the filtration efficiency of a woven fabric: The role of multiple lengthscales. Physics of Fluids 34:033301. doi:10.1063/5.0074229.
  • DELVE Initiative. 2020. Face masks for the general public. DELVE Report 1.
  • Deutsche Welle. 2021. Bavaria mandates FFP2 masks, all of Germany may follow. Accessed January 26, 2021. https://www.dw.com/en/bavaria-mandates-ffp2-masks-all-of-germany-may-follow/a-56267230.
  • Duncan, S., P. Bodurtha, and S. Naqvi. 2020. N95 respirators, disposable procedure masks and reusable cloth face coverings: Total inward leakage and filtration efficiency of materials against aerosol. PLoS ONE 16 (10):e0258191. doi:10.1371/journal.pone.0258191
  • European Committee for Standardization. 2019a. Medical face masks – Requirements and test methods. EN 14683:2019, European Committee for Standardization.
  • European Committee for Standardization. 2019b. Respiratory protective devices – Methods of test – Part 7: Determination of particle filter penetration. EN 13274-7:2019, European Committee for Standardization.
  • Fears, A. C., W. B. Klimstra, P. Duprex, A. Hartman, S. C. Weaver, K. S. Plante, D. Mirchandani, J. A. Plante, P. V. Aguilar, D. Fernández, et al. 2020. Persistence of severe acute respiratory syndrome coronavirus 2 in aerosol suspensions. Emerg. Infect. Dis. 26 (9):2168–71. doi:10.3201/eid2609.201806.
  • Fischer, E. P., M. C. Fischer, D. Grass, I. Henrion, W. S. Warren, and E. Westman. 2020. Low-cost measurement of facemask efficacy for filtering expelled droplets during speech. Sci. Adv. 6 (36):eabd3083. doi:10.1126/sciadv.abd3083.
  • Foster, A., and M. Kinzel. 2021. Estimating COVID-19 exposure in a classroom setting: A comparison between mathematical and numerical models. Phys. Fluids 33 (2):021904. doi:10.1063/5.0040755.
  • Freitag, S., S. G. Howell, and K. T. C. Jim. 2020. Why simple face masks are unexpectedly efficient in reducing viral aerosol transmissions. Preprint, Public and Global Health.
  • Gammaitoni, L., and M. C. Nucci. 1997. Using a mathematical model to evaluate the efficacy of TB control measures. Emerg. Infect. Dis. 3 (3):335–42. doi:10.3201/eid0303.970310.
  • Greenhalgh, T., M. B. Schmid, T. Czypionka, D. Bassler, and L. Gruer. 2020. Face masks for the public during the covid-19 crisis. BMJ. 369:m1435. doi:10.1136/bmj.m1435.
  • Gregson, F. K. A., N. A. Watson, C. M. Orton, A. E. Haddrell, L. P. McCarthy, T. J. R. Finnie, N. Gent, G. C. Donaldson, P. L. Shah, J. D. Calder, et al. 2021. Comparing aerosol concentrations and particle size distributions generated by singing, speaking and breathing. Aerosol Sci. Technol. 55 (6):681–91. doi:10.1080/02786826.2021.1883544.
  • Grinshpun, S. A., H. Haruta, R. M. Eninger, T. Reponen, R. T. McKay, and S.-A. Lee. 2009. Performance of an N95 filtering facepiece particulate respirator and a surgical mask during human breathing: Two pathways for particle penetration. J. Occup. Environ. Hyg. 6 (10):593–603. doi:10.1080/15459620903120086.
  • Guo, Y., J. Wei, C. Ou, L. Liu, S. Sadrizadeh, T. Jin, L. Tang, Y. Zhang, and Y. Li. 2020. Deposition of droplets from the trachea or bronchus in the respiratory tract during exhalation: A steady-state numerical investigation. Aerosol Sci. Technol. 54 (8):869–79. doi:10.1080/02786826.2020.1772459.
  • Hao, W., A. Parasch, S. Williams, J. Li, H. Ma, J. Burken, and Y. Wang. 2020. Filtration performances of non-medical materials as candidates for manufacturing facemasks and respirators. Int. J. Hyg. Environ. Health 229:113582. doi:10.1016/j.ijheh.2020.113582.
  • Hawks, S. A., A. J. Prussin, S. C. Kuchinsky, J. Pan, L. C. Marr, and N. K. Duggal. 2021. Infectious SARS-CoV-2 is emitted in aerosol particles. mBio 12 (5):e02527–21. doi:10.1128/mBio.02527-21.
  • Hossain, E., S. Bhadra, H. Jain, S. Das, A. Bhattacharya, S. Ghosh, and D. Levine. 2020. Recharging and rejuvenation of decontaminated N95 masks. Phys. Fluids 32 (9):093304. doi:10.1063/5.0023940.
  • Howard, J., A. Huang, Z. Li, Z. Tufekci, V. Zdimal, H.-M. van der Westhuizen, A. von Delft, A. Price, L. Fridman, L.-H. Tang, et al. 2021. An evidence review of face masks against COVID-19. Proc. Natl. Acad. Sci. USA 118 (4):e2014564118. doi:10.1073/pnas.2014564118.
  • Jacot, D., G. Greub, K. Jaton, and O. Opota. 2020. Viral load of SARS-CoV-2 across patients and compared to other respiratory viruses. Microbes and Infection 22 (10):617–21. doi:10.1016/j.micinf.2020.08.004.
  • Jimenez, J.-L., K. Human, and K. Simpkins. 2020. Covid-19 airborne transmission tool available. https://cires.colorado.edu/news/covid-19-airborne-transmission-tool-available.
  • Jin, Y., H. Yang, W. Ji, W. Wu, S. Chen, W. Zhang, and G. Duan. 2020. Virology, epidemiology, pathogenesis, and control of COVID-19. Viruses 12 (4):372. doi:10.3390/v12040372.
  • Johnson, G., L. Morawska, Z. Ristovski, M. Hargreaves, K. Mengersen, C. Chao, M. Wan, Y. Li, X. Xie, D. Katoshevski, et al. 2011. Modality of human expired aerosol size distributions. J. Aerosol Sci. 42 (12):839–51. doi:10.1016/j.jaerosci.2011.07.009.
  • Jones, C. R., F. W. Hamilton, A. Thompson, T. T. Morris, and E. Moran. 2021. SARS-CoV-2 IgG seroprevalence in healthcare workers and other staff at North Bristol NHS Trust: A sociodemographic analysis. J. Infect 82 (3):e24–e27. doi:10.1016/j.jinf.2020.11.036.
  • Jones, T. C., G. Biele, B. Mühlemann, T. Veith, J. Schneider, J. Beheim-Schwarzbach, T. Bleicker, J. Tesch, M. L. Schmidt, L. E. Sander, F. Kurth, P. Menzel, R. Schwarzer, M. Zuchowski, J. Hofmann, A. Krumbholz, A. Stein, A. Edelmann, V. M. Corman, and C. Drosten. 2021. Estimating infectiousness throughout SARS-CoV-2 infection course, Science 373 (6551):eabi5273. doi:10.1126/science.abi5273.
  • Kanimozhi, G., B. Pradhapsingh, C. Singh Pawar, H. A. Khan, S. H. Alrokayan, and N. R. Prasad. 2021. SARS-CoV-2: Pathogenesis, molecular targets and experimental models. Front. Pharmacol. 12:638334. doi:10.3389/fphar.2021.638334.
  • Konda, A., A. Prakash, G. A. Moss, M. Schmoldt, G. D. Grant, and S. Guha. 2020a. Aerosol filtration efficiency of common fabrics used in respiratory cloth masks. ACS Nano. 14 (8):10742–3. doi:10.1021/acsnano.0c04676.
  • Konda, A., A. Prakash, G. A. Moss, M. Schmoldt, G. D. Grant, and S. Guha. 2020b. Response to letters to the editor on aerosol filtration efficiency of common fabrics used in respiratory cloth masks: Revised and expanded results. ACS Nano 14 (9):10764–70. doi:10.1021/acsnano.0c04897.
  • Kravtsov, A., H. B. Nig, S. Zhandarov, and R. Beyreuther. 2000. The electret effect in polypropylene fibers treated in a corona discharge. Adv. Polym. Technol. 19 (4):312–6. doi:10.1002/1098-2329(200024)19:4<312::AID-ADV7>3.0.CO;2-X.
  • Li, H., F. Y. Leong, G. Xu, C. W. Kang, K. H. Lim, B. H. Tan, and C. M. Loo. 2021. Airborne dispersion of droplets during coughing: A physical model of viral transmission. Sci. Rep. 11 (1):4617. doi:10.1038/s41598-021-84245-2.
  • Liu, L., J. Wei, Y. Li, and A. Ooi. 2017. Evaporation and dispersion of respiratory droplets from coughing. Indoor Air 27 (1):179–90. doi:10.1111/ina.12297.
  • Lustig, S. R., J. J. H. Biswakarma, D. Rana, S. H. Tilford, W. Hu, M. Su, and M. S. Rosenblatt. 2020. Effectiveness of common fabrics to block aqueous aerosols of virus-like nanoparticles. ACS Nano 14 (6):7651–8. doi:10.1021/acsnano.0c03972.
  • Masks4All. 2020. What countries require masks in public or recommend masks? Accessed January 23, 2020. https://masks4all.co/what-countries-require-masks-in-public/.
  • Milton, D. K., M. P. Fabian, B. J. Cowling, M. L. Grantham, and J. J. McDevitt. 2013. Influenza virus aerosols in human exhaled breath: Particle size, culturability, and effect of surgical masks. PLoS Pathog. 9 (3):e1003205. doi:10.1371/journal.ppat.1003205.
  • Mittal, R., R. Ni, and J.-H. Seo. 2020. The flow physics of COVID-19. J. Fluid Mech. 894:F2. doi:10.1017/jfm.2020.330.
  • Morawska, L., and J. Cao. 2020. Airborne transmission of SARS-CoV-2: The world should face the reality. Environ. Int. 139:105730. doi:10.1016/j.envint.2020.105730.
  • Morawska, L., G. Johnson, Z. Ristovski, M. Hargreaves, K. Mengersen, S. Corbett, C. Chao, Y. Li, and D. Katoshevski. 2009. Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities. J. Aerosol Sci. 40 (3):256–69. doi:10.1016/j.jaerosci.2008.11.002.
  • Nicas, M., W. W. Nazaroff, and A. Hubbard. 2005. Toward understanding the risk of secondary airborne infection: Emission of respirable pathogens. J. Occup. Environ. Hyg. 2 (3):143–54. doi:10.1080/15459620590918466.
  • Oberg, T., and L. M. Brosseau. 2008. Surgical mask filter and fit performance. Am. J. Infect. Control 36 (4):276–82. doi:10.1016/j.ajic.2007.07.008.
  • Poon, W. C. K., A. T. Brown, S. O. L. Direito, D. J. M. Hodgson, L. L. Nagard, A. Lips, C. E. MacPhee, D. Marenduzzo, J. R. Royer, A. F. Silva, et al. 2020. Soft matter science and the COVID-19 pandemic. Soft Matter 16 (36):8310–24. doi:10.1039/d0sm01223h.
  • Prather, K. A., L. C. Marr, R. T. Schooley, M. A. Mc-Diarmid, M. E. Wilson, and D. K. Milton. 2020. Airborne transmission of SARS-CoV-2. Science 370 (6514):303–4. doi:10.1126/science.abf0521.
  • Prather, K. A., C. C. Wang, and R. T. Schooley. 2020. Reducing transmission of SARS-CoV-2. Science 368 (6498):1422–24. doi:10.1126/science.abc6197.
  • Rengasamy, S., B. C. Eimer, and J. Szalajda. 2014. A Quantitative assessment of the total inward leakage of NaCl aerosol representing submicron-size bioaerosol through N95 filtering facepiece respirators and surgical masks. J. Occup. Environ. Hyg. 11 (6):388–96. doi:10.1080/15459624.2013.866715.
  • Riley, E. C., G. Murphy, and R. L. Riley. 1978. Airborne spread of measles in a suburban elementary school. Am. J. Epidemiol. 107 (5):421–32. doi:10.1093/oxfordjournals.aje.a112560.
  • Robinson, J. F., I. Rios de Anda, F. J. Moore, J. P. Reid, R. P. Sear, and C. P. Royall. 2021. Efficacy of face coverings in reducing transmission of COVID-19: Calculations based on models of droplet capture. Phys. Fluids 33 (4):043112. doi:10.1063/5.0047622.
  • Robinson, J. F., and R. P. Sear. 2021. Maskflow: A Python package to evaluate filtration properties of face masks and coverings. doi:10.5281/zenodo.5643961.
  • Santarpia, J. L., V. L. Herrera, D. N. Rivera, et al. (2021). The size and culturability of patient-generated SARS-CoV-2 aerosol. J Expo Sci Environ Epidemiol. doi:10.1038/s41370-021-00376-8.
  • Scharfman, B. E., A. H. Techet, J. W. M. Bush, and L. Bourouiba. 2016. Visualization of sneeze ejecta: Steps of fluid fragmentation leading to respiratory droplets. Exp. Fluids 57 (2):24. doi:10.1007/s00348-015-2078-4.
  • Sharma, S.,. R. Pinto, A. Saha, S. Chaudhuri, and S. Basu. 2021. On secondary atomization and blockage of surrogate cough droplets in single- and multilayer face masks. Sci. Adv. 7 (10):eabf0452. doi:10.1126/sciadv.abf0452.
  • Tang, J. W., T. J. Liebner, B. A. Craven, and G. S. Settles. 2009. A schlieren optical study of the human cough with and without wearing masks for aerosol infection control. J. R Soc. Interface 6 (suppl_6):S727–36. doi:10.1098/rsif.2009.0295.focus.
  • Tang, J. W., A. D. G. Nicolle, J. Pantelic, M. Jiang, C. Sekhr, D. K. W. Cheong, and K. W. Tham. 2011. Qualitative Real-time schlieren and shadowgraph imaging of human exhaled airflows: An aid to aerosol infection control. PLoS One. 6 (6):e21392. doi:10.1371/journal.pone.0021392.
  • Tellier, R. 2009. Aerosol transmission of influenza A virus: A review of new studies. J. R. Soc. Interface 6 (suppl 6):S783–90.
  • U.S. Public Health Service. 1995. Usa Code of Federal Regulations: Part 84 – Approval of respiratory protection devices. 60 FR 30336, U.S. Public Health Service.
  • Viola, I. M., B. Peterson, G. Pisetta, G. Pavar, H. Akhtar, F. Menoloascina, E. Mangano, K. E. Dunn, R. Gabl, A. Nila, et al. 2021. Face coverings, aerosol dispersion and mitigation of virus transmission risk. IEEE Open J Eng Med Biol 2:26–35. doi:10.1109/OJEMB.2021.3053215.
  • Vuorinen, V.,. M. Aarnio, M. Alava, V. Alopaeus, N. Atanasova, M. Auvinen, N. Balasubramanian, H. Bordbar, P. Erästö, R. Grande, et al. 2020. Modelling aerosol transport and virus exposure with numerical simulations in relation to SARS-CoV-2 transmission by inhalation indoors. Saf. Sci. 130:104866. doi:10.1016/j.ssci.2020.104866.
  • Wang, C-s., and Y. Otani. 2013. Removal of nanoparticles from gas streams by fibrous filters: A review. Ind. Eng. Chem. Res. 52 (1):5–17. doi:10.1021/ie300574m.
  • Wang, Y. 2020. Filtration performance of common household materials for manufacturing homemade masks. Accessed January 04, 2022. https://www.tinyurl.com/ve28f3l.
  • Xie, X.,. Y. Li, A. T. Y. Chwang, P. L. Ho, and W. H. Seto. 2007. How far droplets can move in indoor environments-revisiting the Wells evaporation-falling curve. Indoor Air 17 (3):211–25. doi:10.1111/j.1600-0668.2007.00469.x.
  • YouGov. 2020. Poll: Personal measures taken to avoid covid-19. https://today.yougov.com/topics/international/articles-reports/2020/03/17/personal-measures-taken-avoid-covid-19.
  • Zangmeister, C. D., J. G. Radney, E. P. Vicenzi, and J. L. Weaver. 2020. Filtration efficiencies of nanoscale aerosol by cloth mask materials used to slow the spread of SARS-CoV-2. ACS Nano 14 (7):9188–200. doi:10.1021/acsnano.0c05025.
  • Zhang, Z.,. C. Kleinstreuer, and S. Hyun. 2012. Size-change and deposition of conventional and composite cigarette smoke particles during inhalation in a subject specific airway model. J. Aerosol Sci. 46:34–52. doi:10.1016/j.jaerosci.2011.12.002.
  • Zoller, J., J. Meyer, and A. Dittler. 2021. A critical note on filtering-face-piece filtration efficiency determination applying en 149. J. Aerosol Sci. 158:105830. doi:10.1016/j.jaerosci.2021.105830.
  • Zou, L., F. Ruan, M. Huang, L. Liang, H. Huang, Z. Hong, J. Yu, M. Kang, Y. Song, J. Xia, et al. 2020. SARS-CoV-2 viral load in upper respiratory specimens of infected patients. N. Engl. J. Med. 382 (12):1177–9. doi:10.1056/NEJMc2001737.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.