285
Views
0
CrossRef citations to date
0
Altmetric
Original Article

Low-High and High-Low Biphasic Injection Forms in Computed Tomography Examinations of the Upper Abdomen

, , &
Pages 10-14 | Accepted 02 Sep 2005, Published online: 09 Jul 2009
 

Abstract

Purpose: To analyze the influence of different biphasic and monophasic injection rate protocols in abdominal computed tomography (CT).

Material and Methods: A randomized, consecutive, parallel group study was designed and conducted in 60 patients studied with the same CT helical protocol. Patients were randomly distributed into three groups: (A) monophasic (120 ml at 2.5 ml/s); (B) low-high biphasic (120 ml, first 60 ml at a rate of 2 ml/s, the other 60 ml at 2.5 ml/s); and (C) high-low biphasic (120 ml, first 60 ml at a rate of 2.5 ml/s, the other 60 ml at 2 ml/s). All patients were injected with 300 mg I/ml non-ionic contrast media at a fixed delay time of 55 s. Contrast enhancement efficacy was evaluated by attenuation coefficient measurements.

Results: Although non-significant, monophasic protocol enhancements were higher than biphasic protocol enhancements in all measurements except aortic bifurcation (p = 0.003). At this level, biphasic protocols obtained an increased mean enhancement from 7.6% to 2.5% compared to monophasic protocols.

Conclusion: Monophasic contrast agent injection in helical CT of the upper abdomen produces a higher enhancement of parenchymal and venous structures. No significant difference was observed between low-high and high-low biphasic protocols.

Log in via your institution

Log in to Taylor & Francis Online

There are no offers available at the current time.

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.