Purpose: To evaluate the effect of radiation dose reduction on image quality in computed musculoskeletal radiography and determine optimal exposure range.

Material and Methods: In 11 corpses, 1 hand and 1 hip were examined with film-screen radiography, and a series of computed radiographs was obtained using exactly the same technique except for the exposure, which was 100, 50, 25, 12.5, 6.25, and 1.56% of the mAs numbers used for the film-screen images. The computed hip radiographs were processed in 2 different ways, one simulating the film-screen images and one using contrast enhancement. Four radiologists reviewed the images regarding the following parameters: cortical bone, trabecular bone, joint space, and soft tissue, giving each a diagnostic quality rating on a scale from 1 to 5. The median and mean values were found for the pooled results.

Results: For the hands, the computed radiographs were ranked inferior to the film-screen images for all parameters except soft tissue, where the computed radiographs scored higher. The computed images with 50 and 25% exposure were ranked equal to the 100% ones. The quality rating slowly declined with lower exposures. For the hips, the 100 and 50% computed radiographs were generally similar to or slightly better than the film-screen images. The decline was somewhat faster than for the hands. The contrast-enhanced hip images scored less than the nonenhanced images at any given exposure for all parameters except soft tissue, where the contrast-enhanced images scored better at all exposures. The difference between nonenhanced and enhanced images became less at the lower exposures.

Conclusion: Lowering the exposure in computed musculoskeletal radiography below the level of film-screen radiography is feasible, especially in the peripheral skeleton. Contrast enhancement seems to be valuable only in the evaluation of soft-tissue structures.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.