413
Views
15
CrossRef citations to date
0
Altmetric
Original Articles

The effects of varying frequency and duration of mechanical stimulation on a tissue-engineered tendon construct

, &
Pages 167-177 | Received 20 Oct 2016, Accepted 21 Apr 2017, Published online: 08 Jun 2017
 

ABSTRACT

Decellularized, discarded human tissues, such as the human umbilical vein, have been widely utilized for tissue engineering applications, including tendon grafts. When recellularized, such natural scaffolds are cultured in 3D dynamic culture environments (bioreactor systems). For tendon tissue-engineered grafts, such systems often employ oscillatory mechanical stimulation in the form uniaxial tensile strain. The three main parameters of such stimulation are frequency, duration, and force. In this study we investigated the effects of changing the duration (0.5, 1, and 2 h/day) and frequency (0.5, 1, 2 cycles/min) of stimulation of a human umbilical vein seeded with mesenchymal stem cells cultured for up to 7 days. Strain of the construct was held constant at 2%. The highest proliferation rates were observed in the 0.5 h/day duration and 1 cycle/min frequency (203% increase) with a close second being 1 h/day and 1 cycle/min frequency (170% increase). Static cultures along with a 2 cycles/min frequency and a 2 h/day duration of stretching did not increase cellular proliferation significantly. Extracellular matrix quality and alignment of the construct fibers had a direct relation to cellularity and those groups with the highest cellularity improved the most. Gene expression indicated cellular activity consistent with tendon-like tissue remodeling. In addition, scleraxis, tenascin-C, and tenomodulin were upregulated in certain groups after 7 days, with osteoblast, chondrocyte, and adipocyte phenotypes depressed. The stimulation parameters investigated in this study indicated that slower frequencies and shorter durations were best for construct quality in early stage cultures.

Acknowledgment

The authors would like to acknowledge the Women’s Center in Norman Regional Hospital for obtaining and providing the umbilical cords utilized in this study.

Declaration of interest

The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the article.

Funding

This work was supported by the Oklahoma Center for the Advancement of Science and Technology (Grant No. HR09-085).

Additional information

Funding

This work was supported by the Oklahoma Center for the Advancement of Science and Technology (Grant No. HR09-085).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 1,908.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.