Poly(lauryl methacrylate-co-1,6-hexanediol ethoxylate diacrylate) modified silica-based dispersive solid-phase extraction for determination of phenylurea herbicides in environmental water samples

, &
Pages 830-843 | Received 01 Apr 2018, Accepted 18 Jul 2018, Published online: 10 Aug 2018
 

ABSTRACT

In this study, poly(lauryl methacrylate-co-1,6-hexanediol ethoxylate diacrylate) (LMA-HEDA) was synthesised on silanised silica through free-radical cross-linking polymerisation process. The optimal preparation process was obtained by investigating the effects of polymerisation temperature and reaction time. Characterisation of the LMA-HEDA-modified silica was achieved using diffuse reflectance FT-IR. The resulting LMA-HEDA-modified silica was then utilised as a sorbent for dispersive solid-phase extraction (dSPE) of phenylurea herbicides (PUHs) from various environmental water samples. The optimisation of LMA-HEDA-based dSPE process was achieved by investigating the effect of the following parameters including extraction time, pH of sample solution, composition of elution solvent and addition of salt on the extraction recovery of PUHs from water samples. Gradient elution was performed to analyse the extracted PUHs by high performance liquid chromatography (HPLC) with UV-photodiode array detection. Acceptable matrix effect was observed using the proposed LMA-HEDA-based dSPE-HPLC-UV for determining PUHs in environmental water samples. Relatively low detection limits (0.027–0.053 ng mL−1) and good linearity (0.1–4.0 ng mL−1; r2 > 0.999) for individual PUHs were obtained using the proposed method. The proposed method offered detection limits lower than the allowed permissible level (0.1 ng mL−1) set by European Union. The enrichment factors of target PUHs were also estimated at 40.3–47.7. Good extraction recoveries (80.1–97.9%) for PUHs-spiked water samples were obtained with relative standard deviations lower than 8.7%. The intra-day/inter-day precision (0.7–4.6%/0.2–5.9%) and accuracy (96.7–104.2%/95.3–103.6%) of the proposed method were also evaluated in this study. In addition, the applicability of the developed method was demonstrated by the measurement of PUHs in various environmental water samples.

Acknowledgments

This work was supported by the Ministry of Science and Technology of Taiwan (MOST 103-2632-M-031-001-MY3 and MOST 106-2113-M-031-002).

Declaration of interest statement

The authors declared no conflict of interest.

Supplementary material

Supplementary data for this article can be assessed here

Additional information

Funding

This work was supported by the Ministry of Science and Technology, Taiwan [MOST 103-2632-M-031-001-MY3, MOST 106-2113-M-031-002];

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 1,223.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.