151
Views
4
CrossRef citations to date
0
Altmetric
Research Article

Synthesis and characterisation of MCM-41@SiO2-NH-pydc as a new nano mesoporous sorbent: application for the simultaneous preconcentration of cationic dyes previous spectrophotometric determination, using taguchi experimental design

, &
Pages 4379-4397 | Received 18 Feb 2021, Accepted 27 Apr 2021, Published online: 02 Jun 2021
 

ABSTRACT

In this study, a new nano mesoporous MCM-41@SiO2-NH-pydc was successfully synthesised and was used as a new and low-cost adsorbent for the simultaneous influential clean-up, preconcentration and determination of crystal violet (CV) and auramine O (AO) dyes. The as-synthesised sorbent was characterised by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), field emission scanning electron microscopy (FESEM), energy dispersive X-ray analysis (EDX), thermogravimetric (TGA) and derivative thermogravimetric (DTG) and Brunauer–Emmett–Teller (BET) techniques. The extraction performance was evaluated by dispersive solid phase micro extraction (DSPME) of CV and AO from real samples. The analysis was carried out by UV-Vis spectrophotometric. The analytical results confirmed that theMCM-41@SiO2-NH-pyd could be an appropriate candidate as asorbent forDSPME. The maximum recoveries (95.95% and 92.95% for CV and AO, respectively) was obtained at 0.015 g MCM-41@SiO2-NH-pydc sorbent, pH = 8.0, 500 μL DMF as eluent solvent, 20 and 10 min extraction and centrifuge time, respectively, and 50 second desorption time. After the optimum conditions, the limit of detection (LOD), quantification (LOQ) and linear range were obtained, 0.0010, 0.0033 and 0.008–0.6 mg L−1 for CV and 0.0056, 0.0187 and 0.03–1.5 mg L−1for AO, respectively. The relative standard deviations (RSD) for five analyses were 4.2% for CV and 4.6% for AO. In comprising with the previous reported methods, the developed method provided a relatively in expensive, time-saving and environmentally friendly advantages. The developed analytical method can be applied for the determination of CV and AO with sufficient sensitivity as well as acceptable reproducibility.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 1,223.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.