Respiratory inductive plethysmography accuracy at varying PEEP levels and degrees of acute lung injury

, , , , &
Pages 166-175 | Received 21 Sep 2005, Accepted 15 Dec 2005, Published online: 09 Jul 2009
 

Abstract

Background and objective: This study was performed to assess the accuracy of respiratory inductive plethysmographic (RIP) estimated lung volume changes at varying positive end-expiratory pressures (PEEP) during different degrees of acute respiratory failure.

Methods: Measurements of inspiratory tidal volume were validated in eight piglets during constant volume ventilation at incremental and decremental PEEP levels and with increasing severity of pulmonary injury. RIP accuracy was assessed with calibration from the healthy state, from the disease state as the measurement error was assessed, and at various PEEP levels.

Results: Best results (bias 3%, precision 7%) were obtained in healthy animals. RIP accuracy decreased with progressing degrees of acute respiratory failure and was PEEP dependent, unless RIP was calibrated again. When calibration was performed in the disease state as the measurement error was assessed, bias was reduced but precision did not improve (bias – 2%, precision 9%).

Conclusions: RIP accuracy is within the accuracy range found in monitoring devices currently in clinical use. Most reliable results with RIP are obtained when measurements are preceded by calibration in pulmonary conditions that are comparable to the measurement period. When RIP calibration is not possible, fixed weighting of the RIP signals with species and subject size adequate factors is an alternative. Measurement errors should be taken into account with interpretation of small volume changes.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 706.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.