662
Views
15
CrossRef citations to date
0
Altmetric
Research Articles

A three-dimensional finite element analysis of the human hip

, , , &
Pages 546-552 | Received 30 Nov 2018, Accepted 28 Jan 2019, Published online: 15 Mar 2019
 

Abstract

A three-dimensional hip model was created from the MRI scans of one human subject based on constructing the entire pelvis and femur. The ball and socket joint was modelled between the hip’s acetabulum and the femoral head to analyse the multiaxial loads applied in the hip joint. The three key ligaments that reinforce the external surface of the hip to help to stabilise the joint were also modelled which are the iliofemoral, the pubofemoral and ischiofemoral ligaments. Each of these ligaments wraps around the joint connection to form a seal over the synovial membrane, a line of attachment around the head of the femur. This model was tested for different loading and boundary conditions to analyse their sensitivities on the cortical and cancellous tissues of the human hip bones. The outcomes of a one-legged stance finite element analysis revealed that the maximum of 0.056 mm displacement occurred. The stress distribution varied across the model which the majority occurring in the cortical femur and dissipating through the cartilage. The maximum stress value occurring in the joint was 110.1 MPa, which appeared at the free end of the proximal femur. This developed finite element model was validated against the literature data to be used as an asset for further research in investigating new methods of total hip arthroplasty, to minimise the recurrence of dislocations and discomfort in the hip joint, as well as increasing the range of movement available to a patient after surgery.

Acknowledgements

The authors would like to thank Christina Doyle and Andrew John Timperley for the knowledge and resources they provided, which helped define the project. Also, we appreciate the “Simpleware software solutions” for providing the ScanIP software, especially Philippe Young for all his support. Also, we thank the anonymous reviewers for their insightful comments and suggestions.

Disclosure statement

No potential conflict of interest was reported by the authors.

Ethical approval

Approved by the CEMPS ethics committee, University of Exeter, with the reference number: eEMPS000040 v3.0.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 706.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.