Pre-Operative Planning of a DCR Surgery Using Virtual Reality

, , , , , , , , , , , & show all
Received 08 Apr 2024, Accepted 27 May 2024, Published online: 19 Jul 2024
 

ABSTRACT

Purpose

To assess a novel Virtual Reality (VR) tool designed to enhance understanding of the nasal anatomy in patients eligible for DCR surgery.

Methods

Preoperative Computed Tomography (CT) scans of the orbit were obtained and loaded as DICOM (Digital Imaging and Communications in Medicine) files onto the D2P software (3D Systems Inc. Littleton, CO) for tissue segmentation and 3D model preparation. Segmentation was performed on several anatomical structures, including the skull, lacrimal sac, nasal septum, inferior and middle turbinate. The resulting 3D model was visualized using a VR headset. After completing the segmentation procedure, ten cases were evaluated by a panel of six surgeons, including both senior and resident physicians from ENT and oculoplastic specialties.

Results

The dataset under examination comprised images from 10 preoperative CT scans of the orbits of patients eligible for Endo-DCR. When evaluating the CT using the VR tool, in 73.3% of the cases ENT surgeons were right about the side of pathology, while only 43.3% ophthalmologists were right (chi-square, p = .018). In 72.8% of the cases ENT surgeons were evaluated right that there is a septum deviation, while only in 47.2% of the cases the ophthalmologists were right (chi-square, p = .094).

When evaluating the CT using the VR tool, in 60% of the cases consultants were right about the pathology, while 57.7% of the residents were right (chi-square, p = .853). In 81.7% of the cases consultants were evaluated right that there is a septum deviation, while only in 58.3% of the cases the ophthalmologists were right (chi-square, p = .198).

Discussion

ENT surgeons, as well as consultants, interpreted the CT better than the ophthalmologists and residents. Surprisingly, the VR system did not help them to interpret the CT better. Further, more extensive studies should be done to build a VR system that assists in the correct interpretation of the preoperative CT before DCR surgery as well as during DCR surgery.

Supplementary material

Supplemental data for this article can be accessed online at https://doi.org/10.1080/08820538.2024.2378341.

DISCLOSURE STATEMENT

No potential conflict of interest was reported by the author(s).

Additional information

Funding

The author(s) reported that there is no funding associated with the work featured in this article.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 530.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.