Combined effects of holes and winglets on chevron plate-fins to enhance the performance of a plate-fin heat exchanger working with nanofluid

& ORCID Icon
Pages 584-599 | Received 20 Feb 2018, Accepted 08 Jan 2019, Published online: 28 Jan 2019
 

ABSTRACT

The current work reports an experimental study on hydrothermal improvement in a chevron plate-fin heat exchanger combined with holes and winglets. The experiments are performed for water flow through a test square duct fitted with enhanced chevron plate-fins for the Reynolds number from 4000 to 10000. Characteristics of the enhanced chevron plate-fins include three waviness aspect ratios and four different arrangements of holes and winglets at a constant diameter of holes and width/height of winglets. An overall performance factor is applied to obtain the optimal geometry. Then, only the optimal geometries are applied to find out the effect of Al2O3/water nanofluid flow on the performance of a plate-fin heat exchanger. In comparison to simple chevron plate-fins, the enhanced ones would increase the Nusselt number by a factor between 1.05% and 1.6%. In addition, simultaneous application of the optimal enhanced chevron plate-fins and the nanofluid could increase the Nusselt number. The best working conditions of this system are detected for the nanofluid at a weight fraction of 0.3%.

Nomenclature

A=

total surface area, m2

cp=

specific heat capacity, J kg−1 K−1

Dh=

hydraulic diameter, m

G=

mass velocity, kg m−2 s−1

h=

heat transfer coefficient W m−2 K−1

L=

test section length, m

Qconv=

convective heat transfer rate, W

p=

pressure, Pa

∆p=

pressure drop, Pa

T=

temperature, K

∆T=

temperature difference, K

V=

volumetric flow rate, m3 s−1

Greek symbols

ρ=

density, kg m−3

κ=

thermal conductivity, W m−1 K−1

Dimensionless groups

f=

Friction factor

Nu=

Nusselt number

Pr=

Prandtl number

Re=

Reynolds number

Subscripts

b=

bulk fluid

Enh=

enhanced

in=

inlet

LMTD=

logarithmic mean temperature difference

out=

outlet

PP=

pumping power

Sim=

simple

w=

wall

Acronyms

OPF=

overall performance factor

Acknowledgments

Supports for this work by the Islamic Azad University of Shahrood Branch are gratefully acknowledged.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 352.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.