Abstract
Objectives
Autoimmune antibody profiling plays a prominent role in both classification and prognosis of systemic sclerosis (SSc). In the last years novel autoantibodies have been discovered and have become available in diagnostic assays. However, standardization in autoimmune serology is lacking, which may have a negative impact on the added value of autoantibodies in diagnosis and prognosis of SSc. In this paper we describe the comparison of commercially available diagnostic assays for the detection of SSc-associated autoantibodies and explored the coexistence of multiple SSc-associated autoantibodies within patients.
Methods
Serum samples of 347 patients from the Nijmegen Systemic Sclerosis Cohort were included in this study. All patients fulfilled the ACR/EULAR 2013 classification criteria for SSc and were classified as DcSSc or LcSSc according to the Leroy and Medsger criteria. All samples were evaluated on standard laboratory diagnostic tests for detection of SSc-specific autoantibodies CENPA and CENPB (ACA), Scl-70 (ATA), RNA Polymerase III (rp11/155) (ARA), and SSc-associated autoantibodies Fibrillarin, Th-To, PM-scl75, PM-Scl100, RNP68/A/C, Ku, NOR90, and PDGFR from suppliers EUROIMMUN, D-tek and Thermo Fisher Scientific.
Results
We found that 79% of the patients was positive for one or more of the SSc autoantibodies. Overall, a high agreement was observed between the diagnostic methods for the SSC-specific autoantibodies listed in the ACR/EULAR criteria (ATA, ACA, and ARA) (Cohen's kappa 0.53–0.97). However, a lower agreement was found for SSc-associated autoantibodies PM-Scl, and Ku, as well as for the SSc-specific autoantibodies fibrillarin and Th-To. Furthermore, the data revealed that the presence of ATA, ARA and ACA is predominantly mutually exclusive, with only a fraction of the patients testing positive for both ATA and ARA.
Conclusion
Our data showed high concordance of prevalent SSc-specific autoantibodies between different diagnostic assays. Further standardisation for low prevalent SSc-specific and SSc-associated autoantibodies is needed.
Acknowledgements
We thank EUROIMMUN, D-tek and Thermo Fisher Scientific for providing the reagents for analysis of autoantibodies. Additionally, we thank Esther van Rijssen and Bram van Cranenbroek for their technical assistance. There has been no significant financial support for this work that could have influenced its outcome.
Ethical approval
The study protocol was reviewed and approved by the local ethics committee. All patients gave written informed consent prior to blood collection.
Disclosure statement
No potential conflict of interest was reported by the author(s).