Abstract
Objectives
The work shows the effect of counting rules, such as analysis magnification and asbestos fiber dimension to be count (with length ≥5 µm or also asbestos fibers with length <5 µm) in the lung asbestos fiber burden analysis for legal medicine evaluations.
Methods
On the same lung tissue samples, two different analyses were carried out to count any asbestos fibers with length ≥1 µm and with length ≥5 µm. Results of the amphibole burden of the two analyses were compared by linear regression analysis on log10-transformed values.
Results
The analysis should be carried out at an appropriate magnification and on samples prepared in such a way as they allow the counting of very fine fibers. If the analysis is limited to the asbestos fibers with length ≥5 µm, there is a high risk of not detecting possible residual chrysotile fiber burden and thinner crocidolite asbestos fibers.
Conclusions
On average we estimated that 1 amphibole fiber with length ≥5 µm corresponds to ∼8 amphibole fibers with length ≥1 µm in the lung. The values of the Helsinki criteria should be updated taking this into account.
Disclosure statement
No potential conflict of interest was reported by the author(s).
Data availability statement
Fiber dimensions and identification for each fiber can be made available on request.