Non-fouling biomaterials based on blends of polyethylene oxide copolymers and polyurethane: simultaneous measurement of platelet adhesion and fibrinogen adsorption from flowing whole blood

, &
Pages 497-506 | Received 07 Mar 2012, Accepted 13 Apr 2012, Published online: 13 Aug 2012
 

Abstract

Measurements of platelet adhesion and fibrinogen adsorption from flowing whole blood to a series of polyethylene oxide (PEO)-based materials were carried out. A unique experimental design was used in which both quantities were measured in the same experiment. The materials consisted of a polyurethane (PU) as a matrix into which various triblock copolymers of general structure PEO-PU-PEO were blended; the PU block was the same in all materials but the PEO blocks ranged in molecular weight from 550 to 5000. Platelets were isolated from fresh human blood and labeled with 51Cr; purified fibrinogen was labeled with 125I. A whole blood preparation containing these labeled species was used for the adhesion/adsorption studies. The surfaces were exposed to the flowing blood in a cone and plate device at a wall shear rate of 300 s−1. It was found that both platelet adhesion and fibrinogen adsorption decreased with increasing copolymer content in the blends and with decreasing PEO block size for a given copolymer content. The block size effect was due probably to higher PEO surface coverage for the lower molecular weight blocks. Fibrinogen adsorption and platelet adhesion were linearly and strongly correlated. The best performing materials showed very low fibrinogen adsorption of the order of 25 ng/cm2, and correspondingly low platelet densities around 10,000 per cm2, i.e. fractional platelet coverage in the vicinity of 0.2%.

Acknowledgments

Financial support of this work by the Canadian Institutes of Health Research (CIHR) and the Natural Sciences and Engineering Research Council of Canada (NSERC) is gratefully acknowledged.

Notes

aEstimated from surface oxygen content as determined by XPS (see Ref. Citation[18]). Coverage of 100% indicates oxygen content the same as the pure copolymer. Coverage of 0% indicates oxygen content the same as the unmodified PU matrix.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 503.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.