166
Views
34
CrossRef citations to date
0
Altmetric
ORIGINAL ARTICLE

Application of Stochastic Measurement Models to Visual Function Rating Scale Questionnaires

, PhD
Pages 103-124 | Received 25 Jul 2004, Accepted 12 Oct 2004, Published online: 08 Jul 2009
 

Abstract

Purpose: To test hypotheses that low vision patient responses to visual function rating scale questionnaires conform to an additive conjoint structure and that the Likert score is a sufficient statistic for the latent patient trait; to compare results for two competing stochastic measurement models; and to determine if different questionnaires measure the same construct in low vision patients. Methods: Visual function rating scale questionnaires were administered to 284 low vision subjects by telephone. Each subject was administered two of four questionnaires: ADVS, NEI VFQ-25 plus supplement, expanded VAQ, and VF-14. Results: Data were analyzed with the Muraki item response model and the Andrich measurement model. The estimates of latent person, item, and response threshold measures from the two models are linearly related. The Muraki model produced a better overall fit to the item response data, the Andrich model produced a better fit to the average ratings for each person and item. Fit statistics for the Andrich model were proportional to the item-dependent discrimination parameter in the Muraki model. The ADVS was the most accurate measure and the NEI VFQ was the least. Reliability was similar for all four instruments. Person measures for each pair of instruments were linearly related indicating that all four instruments measured the same construct. The person measure estimate from the Andrich model is monotonic with the average rating. That relationship suggests a transformation of the Likert score that can correct the floor and ceiling effects in rating scale data.Conclusions: Patient responses to all four questionnaires conform to varying degrees to an additive conjoint structure. The Likert score is a sufficient statistic for the ADVS and the VAQ, but not for the NEI VFQ or VF-14. All four instruments measure the same construct in the low vision population, but they differ in measurement accuracy and precision.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 740.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.