Summary
This paper summarises fatigue strength in laser‐welded butt joints made of Fe P04‐UNI 8092 deep drawing steel with standard and galvanized surfaces. The Wöhler curves obtained are compared with those of a series of seam‐welded joints, which have been subjected to special forging of the beads after welding.