145
Views
5
CrossRef citations to date
0
Altmetric
Original Article

Effects on blood compatibility in vitro by combining a direct P2Y12 receptor inhibitor and heparin coating of stents

, , , &
Pages 318-327 | Received 28 Jun 2005, Accepted 24 Jan 2006, Published online: 07 Jul 2009
 

Abstract

The effect of the direct platelet P2Y12 receptor inhibitor, AR-C69931MX, on activation of blood induced by stents with and without heparin coating was investigated using a whole blood Chandler loop model in vitro. Stents were deployed in Chandler loops. Fresh human blood with heparin and AR-C69931MX was rotated for 1 h at 37°C and used for measurements of platelets, microparticles, thrombin-antithrombin complex (TAT), fibrinogen binding to platelets, P-selectin expression by platelets, CD11b, Prothrombin Fragment F1+2, FXIa-AT, FXIIa-AT, C3a, sC5b-9 and stent score. In the first experiment there were four study groups with unmodified stents: 1a, no AR-C69931MX; 1b, 250 nmol/L; 1c, 750 nmol/L; 1d, 2250 nmol/L of AR-C69931MX. In the second experiment the concentration of AR-C69931MX was 500 nmol/L: 2a; tubings without stent; 2b; tubings with heparin-coated stent; 2c; tubings with unmodified stents. Heparin-coated stents were used in the third experiment: 3a; no AR-C69931MX; 3b; 500 nmol/L of AR-C69931MX. In the first experiment there were significant differences in all parameters analysed except for C3a, and stent score when the group with no AR-C69931MX was compared to all the groups with AR-C69931MX. In the second experiment there were significant differences in platelet count, TAT, FXIa-AT, FXIIa-AT and stent score when unmodified stents were compared to loops with no stents and partly to loops with heparin-coated stents. In the third experiment there was a significant reduction in generation of TAT, stent score and better preservation of platelet number by combining the platelet inhibitor and heparin-coated stents as compared to heparin-coated stents alone. The conclusion is that the direct P2Y12 receptor inhibitor AR-C69931MX reduced the different aspects of activation of blood induced by both unmodified and heparin-coated stents.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.