Evaluation of aspirin response by Multiplate® whole blood aggregometry and light transmission aggregometry

, , , , & , MD, PhD
Pages 415-420 | Received 09 Mar 2009, Accepted 08 Jun 2009, Published online: 01 Sep 2009
 

Abstract

Several studies indicate that a biochemically reduced response to aspirin increases the risk of cardiovascular events. This study was designed to investigate the performance of Multiplate® whole blood aggregometry as regards assessment of platelet function prior to and after aspirin treatment, and to compare it with light transmission aggregometry (LTA). We included 21 healthy individuals and 43 patients with documented coronary artery disease (CAD). Platelet aggregation induced by arachidonic acid 0.5 mM was measured in duplicate by Multiplate® aggregometry and LTA in healthy individuals before aspirin treatment and in all participants on four consecutive days during treatment with 75 mg aspirin daily. Optimal compliance was confirmed by complete suppression of serum thromboxane B2 in all participants. Employing the Multiplate®, the coefficient of variation (CV) was lower at baseline (CV = 8%) than during aspirin treatment in both healthy individuals (CV = 46%) and patients (CV = 46%). During aspirin treatment, the repeatability of LTA was superior to Multiplate® measurements. However, the Multiplate® was superior to LTA as regards the ability to discriminate platelet response before and after aspirin treatment. In conclusion, the repeatability of Multiplate® aggregometry was good before aspirin treatment, whereas the CV was quite high during aspirin treatment in both healthy individuals and patients. However, the Multiplate® device was fully capable of assessing platelet function prior to and after treatment with aspirin. Clinical studies are needed to investigate whether a high platelet aggregation level measured by Multiplate® whole blood aggregometry during aspirin treatment is associated with a poor clinical outcome.

Abbreviations
ANOVA=

analysis of variance

AUC=

area under the curve

AU*min=

aggregation units times minutes

CAD=

coronary artery disease

CV=

coefficient of variation

LTA=

light transmission aggregometry

se-TxB2=

serum thromboxane B2.

Abbreviations
ANOVA=

analysis of variance

AUC=

area under the curve

AU*min=

aggregation units times minutes

CAD=

coronary artery disease

CV=

coefficient of variation

LTA=

light transmission aggregometry

se-TxB2=

serum thromboxane B2.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.