Abstract

Left-ventricular assist devices (LVADs) improve outcomes in end-stage heart failure patients. Two centrifugal-flow LVAD systems are currently approved, HeartMate 3 (HM3) and Medtronic/Heartware HVAD (HVAD). Clinical findings suggest differences in thrombogenicity between both systems. We compared markers of platelet activation and aggregation between HM3 and HVAD. We prospectively included 59 LVAD patients (40 HM3, 19 HVAD). Platelet P-selectin expression, activated glycoprotein (GP) IIb/IIIa and monocyte-platelet aggregates (MPA) were assessed by flow-cytometry. Platelet aggregation was measured by light-transmission aggregometry (LTA) and multiple-electrode aggregometry (MEA). Von-Willebrand factor (VWF) antigen (VWF:Ag), VWF activity (VWF:Ac), and VWF multimer pattern analysis were determined. Soluble P-selectin (sP-selectin) was measured with an enzyme-linked immunoassay. P-selectin, GPIIb/IIIa and MPA levels in vivo and in response to arachidonic acid, adenosine diphosphate, and thrombin receptor activating peptide were similar between HM3 and HVAD (all p > .05). Likewise, agonist-inducible platelet aggregation by LTA and MEA did not differ between HM3 and HVAD (all p > .05). VWF:Ag levels and FVIII:C were similar between both systems (both p > .05), but patients with HVAD had significantly lower VWF:Ac (p = .011) and reduced large VWF multimers (p = .013). Finally, sP-selectin levels were similar in patients with HVAD and HM3 (p = .845). In conclusion, on-treatment platelet activation and aggregation are similar in HM3 and HVAD patients. Potential clinical implications of observed differences in VWF profiles between both LVAD systems need to be addressed in future clinical trials.

GRAPHICAL ABSTRACT

Conflicts of interest

DW is consultant and proctor for Abbott and Medtronic. DZ receives research grants from Abbott and Medtronic, is advisory board member for Abbott, Medtronic and Berlin Heart, and proctor for Abbott and Medtronic. The other authors have no conflict of interest to declare.

Additional information

Funding

The authors have no funding to report.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.