Publication Cover
Physiotherapy Theory and Practice
An International Journal of Physical Therapy
Volume 36, 2020 - Issue 2
389
Views
2
CrossRef citations to date
0
Altmetric
Research Report

Tubing internal diameter affects the pressures and oscillation frequencies generated by the therapist-made bubble-positive expiratory pressure device

, MSc, PT, , PhD, PT, , BS Eng & , PhD, MSc, PT
Pages 333-339 | Received 31 Aug 2017, Accepted 09 Apr 2018, Published online: 13 Jun 2018
 

ABSTRACT

Objectives: To determine the positive expiratory pressures (PEP) and oscillation frequencies generated in the therapist-made-bubble-PEP device using tubing with different internal diameters (IDs). Design: Bench-top experimental study. Therapist-made-bubble-PEP device with a 10 cm column height of water, tubing length of 30 cm with distal end of the tubing resting 3 cm from base of container. Tubing with 2, 4, 5, 7, 8, and 10 mm IDs were tested with flows of 5, 10, 15, 20, and 25 L/min. A pressure transducer measured the pressures and oscillation frequencies. Data were captured with PhysioDAQxs© software and analyzed with Breathalyser© software. Results: Therapist-made-bubble-PEP device with: (1) 2 mm ID tubing with 5 and 10 L/min flows produced mean(SD) PEP of 20.1(0.2) and 41.8(0.5)cmH2O, respectively, oscillation frequencies of 15-19 Hz; (2) 4 mm ID tubing with 5 and 25 L/min flows produced PEP of 12.5(0.2) and 41.5(0.3)cmH2O, oscillations of 14–18 Hz; (3) 5 mm ID tubing with 5 and 25 L/min flows produced PEP of 10.9(0.1) and 15.8(0.1)cmH2O, oscillations of 17–18 Hz; (4) 7 mm ID tubing with 5 and 25 L/min flows produced PEP of 10.7(0.0) and 12.7(0.2)cmH2O, oscillations of 14–17 Hz; (5) 8 mm ID tubing with 5 and 25 L/min flows produced PEP of 10.5(0.0) and 11.4(0.0)cmH2O, oscillations of 14–18 Hz; and (6) 10 mm ID tubing with 5 and 25 L/min flows produced PEP of 10.4(0.1) and 10.8(0.2)cmH2O, oscillations of 13–17 Hz. Conclusions: Therapist-made-bubble-PEP device with tubing of 10 mm ID generated the most stable PEP in relation to water height (10 cm) irrespective of flow compared to tubing with ID of 2, 4, 5, 7, and 8 mm. The oscillation frequencies generated at all flows and tubing IDs were between 13 and 19 Hz.

Acknowledgments

Professor Jenny Peat for contributions to statistical analysis; and Biomedical Engineering, Prince of Wales Hospital, for contributions to equipment calibration.

Declaration of interest

The authors report no declarations of interest.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 325.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.