Development of computer tablet software for clinical quantification of lateral knee compartment translation during the pivot shift test

, , , , , , , , , & show all
Pages 217-228 | Received 10 Jul 2014, Accepted 07 Jan 2015, Published online: 09 Feb 2015
 

Abstract

The pivot shift test is a commonly used clinical examination by orthopedic surgeons to evaluate knee function following injury. However, the test can only be graded subjectively by the examiner. Therefore, the purpose of this study is to develop software for a computer tablet to quantify anterior translation of the lateral knee compartment during the pivot shift test. Based on the simple image analysis method, software for a computer tablet was developed with the following primary design constraint – the software should be easy to use in a clinical setting and it should not slow down an outpatient visit. Translation of the lateral compartment of the intact knee was 2.0 ± 0.2 mm and for the anterior cruciate ligament-deficient knee was 8.9 ± 0.9 mm (p < 0.001). Intra-tester (ICC range = 0.913 to 0.999) and inter-tester (ICC = 0.949) reliability were excellent for the repeatability assessments. Overall, the average percent error of measuring simulated translation of the lateral knee compartment with the tablet parallel to the monitor increased from 2.8% at 50 cm distance to 7.7% at 200 cm. Deviation from the parallel position of the tablet did not have a significant effect until a tablet angle of 45°. Average percent error during anterior translation of the lateral knee compartment of 6mm was 2.2% compared to 6.2% for 2 mm of translation. The software provides reliable, objective, and quantitative data on translation of the lateral knee compartment during the pivot shift test and meets the design constraints posed by the clinical setting.

Acknowledgements

The authors thank Scott L. Maxwell, Jonathan Foster, and Kareem Kandil for their help and assistance in the development of the PIVOT software. This application was filed under US patent ‘Quantified Injury Diagnostics’ (US patent PCT/US2012/067968).

Conflict of interest disclosure statement

No potential conflict of interest was reported by the authors.

Notes

 1. Email: [email protected]

 2. Email: [email protected]

 3. Email: [email protected]

 4. Email: [email protected]

 5. Email: [email protected]

 6. Email: [email protected]

 7. Email: [email protected]

 8. Email: [email protected]

 9. Email: [email protected]

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.