Relationship between myocardial bridge compression severity and haemodynamic perturbations

, &
Pages 752-763 | Received 31 Aug 2018, Accepted 27 Feb 2019, Published online: 18 Mar 2019
 

Abstract

Objectives: This study aims to examine the alteration in coronary haemodynamics with increasing the severity of vessel compression caused by myocardial bridging (MB).

Methods: Angiography and intravascular ultrasound were performed in 10 patients with MB with varying severities of systolic compression in the left anterior descending (LAD) artery. Computer models of MB were developed and transient computational fluid dynamics simulations were performed to derive distribution of blood residence time and shear stress.

Results: With increasing the severity of bridge compression, a decreasing trend was observed in the shear stress over proximal segment whereas an increasing trend was found in the shear stress over bridge segment. When patients were divided into 2 groups based on the average systolic vessel compression in the whole cohort (%CRave = 27.38), patients with bridges with major systolic compression (>%CRave) had smaller shear stress and higher residence time in the proximal segment compared to those with bridges with minor systolic compression (<%CRave) (0.37 ± 0.23 vs 0.69 ± 0.29 Pa and 0.0037 ± 0.0069 vs 0.022 ± 0.0094 s). In contrast, patients with bridges with major systolic compression had greater shear stress in the bridge segment compared to those with bridges with minor systolic compression (2.49 ± 2.06 vs 1.13 ± 0.89 Pa). No significant difference was found in the distal shear stress of patients with bridges with major and minor systolic compression.

Conclusion: Our findings revealed a direct relationship between the severity of systolic compression of MB and haemodynamic perturbations in the proximal segment such that the increased systolic vessel compression was associated with decreased shear stress and increased blood residence time.

Acknowledgment

The authors would like to acknowledge the cardiac catheterization laboratory staff at Tehran Heart Center for their assistance in performing the studies.

Disclosure statement

No potential conflict of interest was reported by the authors.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.