Leaflet stress quantification of porcine vs bovine surgical bioprostheses: an in vitro study

ORCID Icon, , ORCID Icon, ORCID Icon, ORCID Icon &
Pages 40-51 | Received 21 Feb 2020, Accepted 05 May 2021, Published online: 05 Jul 2021
 

Abstract

Calcified aortic stenoses are among the most prevalent form of cardiovascular diseases in the industrialized countries. This progressive disease, with no effective medical therapy, ultimately requires aortic valve replacement – either a surgical or very recently transcatheter aortic valve implantation. Increase leaflet mechanical stress is one of the main determinants of the structural deterioration of bioprosthetic aortic valves. We applied a coupled in vitro/in silico method to compare the timing, magnitude, and regional distribution of leaflet mechanical stress in porcine versus pericardial bioprostheses (Mosaic and Trifecta). A double activation simulator was used for in vitro testing of a bioprosthesis with externally mounted pericardium (Abbott, Trifecta) and a bioprosthesis with internally mounted porcine valve (Medtronic, Mosaic). A non-contact system based on stereophotogammetry and digital image correlation (DIC) with high spatial and temporal resolution (2000 img/s) was used to visualize the valve leaflet motion and perform the three-dimensional analysis. A finite element model of the valve was developed, and the leaflet deformation obtained from the DIC analysis was applied to the finite element model calculate local leaflet mechanical stress throughout the cardiac cycle. The maximum leaflet stress was higher with the pericardial versus the porcine bioprosthesis (2.03 vs. 1.30 MPa) For both bioprostheses the highest values of leaflet stress occurred during diastole and were primarily observed in the upper leaflet edge near the commissures and to a lesser extent in the mid-portion of the leaflet body. In conclusion, the coupled in vitro/in silico method described in this study shows that the highest levels of leaflet stress occur in the regions of the commissures and mid-portion of the leaflet body. This method may have important insight with regard to bioprosthetic valve durability. Our results suggest that, compared to porcine bioprostheses, those with externally mounted pericardium have higher leaflet mechanical stress, which may translate into shorter durability.

Disclosure statement

Pr. Philippe Pibarot reports research grants from Edwards Lifesciences and Medtronic. Régis Rieu reports research grant from Medtronic. All other authors have no conflict of interest to disclose.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.